← Back to ZINDN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Epoxy Glass Flake Anti-corrosive ZD6600

Quick Specs

Epoxy Glass Flake Anti-corrosion Paint ZD6600 belongs to glass flake coatings, epoxy system. Such as immersed zones, tidal zones and splash zones of offshore structures, as well as wharves, hydraulic gates, underground pipelines, etc. Two-component high-solids epoxy paint composed of epoxy resin, glass flake pigment and amine curing agent, etc. Parameters on this page: volume solids 85 ± 3%, dry film thickness 100/200/300 µm, theoretical spreading rate 0.494 kg/m². Comparable products of the same brand: ZD53-62A Epoxy MIO Intermediate Coat, ZD6310-N01F Epoxy Oil-resistant Antistatic Topcoat, ZD6310-N01P Epoxy Oil-resistant Antistatic Primer.

Parameter source: ZINDN original technical data sheet (TDS) "Epoxy Glass Flake Anti-corrosion Paint ZD6600"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids85 ± 3%
Dry Film Thickness100/200/300 µm
Theoretical Spreading Rate0.494 kg/m²
VOC—
Density / Specific Gravity1.4 ± 0.1
Number of ComponentsTwo-component
Flash Point>25 °C (components A, B and the mixture)
ThinnerZX-06 Epoxy Thinner
Mixing RatioComponent A (base) : Component B (curing agent) = 5:1

Browse Similar Models by CategoryThis model belongs to: Glass Flake, Epoxy

ZD6600 Epoxy Glass Flake Anti-corrosion Paint

Product description

Two-component high-solids epoxy paint composed of epoxy resin, glass flake pigment and amine curing agent, etc.

Key features

After curing, forms a tough, wear-resistant and impact-resistant film with excellent permeability resistance;

Resistant to long-term attack by water, sewage, seawater and soil;

Resistant to immersion in crude oil, gasoline/diesel, aviation kerosene and lubricating oil;

Excellent resistance to weak acids, weak alkalis and some salts;

The film has good compatibility with cathodic protection.

Intended use

Suitable for protection of steel and concrete in severely corrosive environments and environments subject to wear. Such as immersed zones, tidal zones and splash zones of offshore structures, as well as wharves, hydraulic gates, underground pipelines, etc. Also suitable for anti-corrosion coatings on the inner walls of liquid tanks and storage tanks; for applicable media, please consult the company.

Specification data

ColourGrey
GlossMatt
Volume Solids85±3%
Mixed density (kg/L)1.4±0.1

Typical film thickness and theoretical spreading rate

Dry film thickness (µm)Minimum 100Typical 200Maximum 300
Wet film thickness (µm)118236354
Theoretical spreading rate (kg/m²)0.1650.3300.494
Practical Spreading RateAllowing for a suitable loss factor

Application instructions

Suitable substrates and surface preparation

All surfaces to be painted shall be clean, dry and free from contaminants; surfaces shall be assessed and prepared in accordance with ISO 8504.

Bare steelRemove grease from the surface, and rinse off salts and other contaminants with fresh water. Remove weld slag, grind sharp edges smooth, blast clean to Sa 2.5 (ISO 8501-1), with surface roughness Rz 50–100 µm.
Shop-primed surfaceWelds, heat-corrected areas and damaged areas must be blast cleaned to Sa 2.5 (ISO 8501-1) or ground with abrasive discs to St 3.
RepairThoroughly remove grease from the surface, and wash off salts and other contaminants with high-pressure fresh water.
Concrete surfaceApply after sealing surface pores with a suitable sealer.
Other surfacesConsult our company.

Application and curing conditions

Application ambient temperature 5–38 °C, relative air humidity not greater than 85%, and steel surface temperature shall be at least 3 °C above the dew point; during application and drying in confined spaces, adequate ventilation is required. Outdoor use is prohibited in adverse weather such as rain, fog, snow, strong wind and heavy dust;

Paint mixing

MixingThis product is supplied as two containers forming one unit. Stir the base thoroughly with a power mixer, add the curing agent in the specified ratio, stir again with a power mixer, and add the recommended thinner to adjust to a suitable application viscosity. Once mixed, use within the specified pot life.
Thinner / Cleaning SolventZX-06 Epoxy Thinner
Mixing ratio (by weight)Component A (base) : Component B (curing agent) = 5:1
Induction TimeNo induction required

Pot life after mixing

5°C15°C25°C35°C
4 h3 h2 h1 h

Application

Application MethodsAirless spray is recommended; air spray is not recommended; brush and roller are recommended only for touch-up, small-area application or repair.

Application parameters

Application MethodsUnitHigh-pressure airless sprayBrush/roller
Spray gun tip sizemm0.43~0.53——
Spray pressurekg/cm²150~200——
Thinning quantity%0~105~10

Drying/curing time and recoat interval

Substrate surface temperature5°C15°C25°C35°C
Touch Dry16 h8 h4 h2 h
Hard Dry48 h24 h12 h6 h
Fully cured14 days10 days6 days4 days
Minimum recoat interval48 h24 h12 h6 h
Maximum recoat intervalSelf-recoat14 days10days6 days4 days
Overcoat with topcoat7 days5 days3 days2 days

Note: the above data are measured under well-ventilated conditions, at typical film thickness and 75% relative humidity, and are for reference only.

Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors. The coating must be fully cured before immersion service.

Typical paint system

PrecedingApproved epoxy primer or direct application to prepared substrate
SubsequentEpoxy glass flake paint or approved topcoat

Packaging, storage and handling

Packaging SpecificationsComponent A 20 kg, Component B 4 kg
Flash Point>25 °C (components A, B and the mixture)
Storage conditionsStore in accordance with national regulations. Keep in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed.
Shelf lifeShelf life is 1 year under good storage conditions.

Health, safety and environmental protection

This product contains flammable materials; site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).

Avoid inhaling solvent vapours and spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures for fire prevention, explosion prevention and environmental protection. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.

Waste disposal must comply with the relevant national or local regulations.

The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.

Version informationPublished in June 2022; this data sheet supersedes all previous versions

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

FAQ

How many components does Epoxy Glass Flake Anti-corrosion Paint ZD6600 have?
Epoxy Glass Flake Anti-corrosion Paint ZD6600 is a two-component product; mix according to the mixing ratio in the "Application Data" table on this page before use.
What is the mixing ratio of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The mixing ratio of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is A (base): B (curing agent) = 5:1.
What is the typical dry film thickness of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The conventional dry film thickness of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is 100/200/300 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The theoretical spreading rate of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is 0.494 kg/m²; the actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The volume solids of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is 85 ± 3%.
What is the gloss of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The gloss of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is matt.
What thinner is used for Epoxy Glass Flake Anti-corrosion Paint ZD6600?
Recommended thinner for Epoxy Glass Flake Anti-corrosion Paint ZD6600: ZX-06 epoxy thinner.
What is the flash point of Epoxy Glass Flake Anti-corrosion Paint ZD6600?
The flash point of Epoxy Glass Flake Anti-corrosion Paint ZD6600 is >25°C (Component A, Component B, and mixture); storage, transport, and application shall follow the product Safety Data Sheet.
How is Epoxy Glass Flake Anti-corrosion Paint ZD6600 applied?
Application method for epoxy glass flake anti-corrosive coating ZD6600: airless spray is recommended; conventional air spray is not recommended; brush and roller application are recommended only for stripe coating, small areas or touch-up; surface preparation and coating systems are as described on this page.
Which standards are involved in Epoxy Glass Flake Anti-corrosion Paint ZD6600?
As recorded in the technical data on this page: ISO8504 (see the application instructions on this page); remove weld spatter, grind sharp edges smooth and blast clean to grade Sa2.5 (ISO8501-1), with a surface roughness Rz of 50-100 µm. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Epoxy Glass Flake Anti-corrosion Paint ZD6600 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Similar models from the same brand — glass flake coating, epoxy coating

View all ZINDN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery