Epoxy Glass Flake Anti-corrosion Paint ZD6600 belongs to glass flake coatings, epoxy system. Such as immersed zones, tidal zones and splash zones of offshore structures, as well as wharves, hydraulic gates, underground pipelines, etc. Two-component high-solids epoxy paint composed of epoxy resin, glass flake pigment and amine curing agent, etc. Parameters on this page: volume solids 85 ± 3%, dry film thickness 100/200/300 µm, theoretical spreading rate 0.494 kg/m². Comparable products of the same brand: ZD53-62A Epoxy MIO Intermediate Coat, ZD6310-N01F Epoxy Oil-resistant Antistatic Topcoat, ZD6310-N01P Epoxy Oil-resistant Antistatic Primer.
Parameter source: ZINDN original technical data sheet (TDS) "Epoxy Glass Flake Anti-corrosion Paint ZD6600"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 85 ± 3% |
|---|---|
| Dry Film Thickness | 100/200/300 µm |
| Theoretical Spreading Rate | 0.494 kg/m² |
| VOC | — |
| Density / Specific Gravity | 1.4 ± 0.1 |
| Number of Components | Two-component |
| Flash Point | >25 °C (components A, B and the mixture) |
| Thinner | ZX-06 Epoxy Thinner |
| Mixing Ratio | Component A (base) : Component B (curing agent) = 5:1 |
ZD6600 Epoxy Glass Flake Anti-corrosion Paint
Two-component high-solids epoxy paint composed of epoxy resin, glass flake pigment and amine curing agent, etc.
After curing, forms a tough, wear-resistant and impact-resistant film with excellent permeability resistance;
Resistant to long-term attack by water, sewage, seawater and soil;
Resistant to immersion in crude oil, gasoline/diesel, aviation kerosene and lubricating oil;
Excellent resistance to weak acids, weak alkalis and some salts;
The film has good compatibility with cathodic protection.
Suitable for protection of steel and concrete in severely corrosive environments and environments subject to wear. Such as immersed zones, tidal zones and splash zones of offshore structures, as well as wharves, hydraulic gates, underground pipelines, etc. Also suitable for anti-corrosion coatings on the inner walls of liquid tanks and storage tanks; for applicable media, please consult the company.
| Colour | Grey |
|---|---|
| Gloss | Matt |
| Volume Solids | 85±3% |
| Mixed density (kg/L) | 1.4±0.1 |
| Dry film thickness (µm) | Minimum 100 | Typical 200 | Maximum 300 |
| Wet film thickness (µm) | 118 | 236 | 354 |
| Theoretical spreading rate (kg/m²) | 0.165 | 0.330 | 0.494 |
| Practical Spreading Rate | Allowing for a suitable loss factor |
|---|
All surfaces to be painted shall be clean, dry and free from contaminants; surfaces shall be assessed and prepared in accordance with ISO 8504.
| Bare steel | Remove grease from the surface, and rinse off salts and other contaminants with fresh water. Remove weld slag, grind sharp edges smooth, blast clean to Sa 2.5 (ISO 8501-1), with surface roughness Rz 50–100 µm. |
|---|---|
| Shop-primed surface | Welds, heat-corrected areas and damaged areas must be blast cleaned to Sa 2.5 (ISO 8501-1) or ground with abrasive discs to St 3. |
| Repair | Thoroughly remove grease from the surface, and wash off salts and other contaminants with high-pressure fresh water. |
| Concrete surface | Apply after sealing surface pores with a suitable sealer. |
| Other surfaces | Consult our company. |
Application ambient temperature 5–38 °C, relative air humidity not greater than 85%, and steel surface temperature shall be at least 3 °C above the dew point; during application and drying in confined spaces, adequate ventilation is required. Outdoor use is prohibited in adverse weather such as rain, fog, snow, strong wind and heavy dust;
| Mixing | This product is supplied as two containers forming one unit. Stir the base thoroughly with a power mixer, add the curing agent in the specified ratio, stir again with a power mixer, and add the recommended thinner to adjust to a suitable application viscosity. Once mixed, use within the specified pot life. |
|---|---|
| Thinner / Cleaning Solvent | ZX-06 Epoxy Thinner |
| Mixing ratio (by weight) | Component A (base) : Component B (curing agent) = 5:1 |
| Induction Time | No induction required |
| 5°C | 15°C | 25°C | 35°C |
| 4 h | 3 h | 2 h | 1 h |
| Application Methods | Airless spray is recommended; air spray is not recommended; brush and roller are recommended only for touch-up, small-area application or repair. |
|---|
| Application Methods | Unit | High-pressure airless spray | Brush/roller |
| Spray gun tip size | mm | 0.43~0.53 | —— |
| Spray pressure | kg/cm² | 150~200 | —— |
| Thinning quantity | % | 0~10 | 5~10 |
| Substrate surface temperature | 5°C | 15°C | 25°C | 35°C | ||
| Touch Dry | 16 h | 8 h | 4 h | 2 h | ||
| Hard Dry | 48 h | 24 h | 12 h | 6 h | ||
| Fully cured | 14 days | 10 days | 6 days | 4 days | ||
| Minimum recoat interval | 48 h | 24 h | 12 h | 6 h | ||
| Maximum recoat interval | Self-recoat | 14 days | 10 | days | 6 days | 4 days |
| Overcoat with topcoat | 7 days | 5 days | 3 days | 2 days |
Note: the above data are measured under well-ventilated conditions, at typical film thickness and 75% relative humidity, and are for reference only.
Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors. The coating must be fully cured before immersion service.
| Preceding | Approved epoxy primer or direct application to prepared substrate |
|---|---|
| Subsequent | Epoxy glass flake paint or approved topcoat |
| Packaging Specifications | Component A 20 kg, Component B 4 kg |
|---|---|
| Flash Point | >25 °C (components A, B and the mixture) |
| Storage conditions | Store in accordance with national regulations. Keep in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. |
| Shelf life | Shelf life is 1 year under good storage conditions. |
This product contains flammable materials; site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).
Avoid inhaling solvent vapours and spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures for fire prevention, explosion prevention and environmental protection. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.
Waste disposal must comply with the relevant national or local regulations.
The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.
| Version information | Published in June 2022; this data sheet supersedes all previous versions |
|---|
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.