Intersleek 7180 Foul-release Tie Coat

Quick Specs

Intersleek 7180 Foul Release Tiecoat belongs to the antifouling coating category. A tiecoat that enables low-temperature application of Intersleek 1000, Intersleek 1100SR and Intersleek 2120 foul release coatings over a wide range of existing antifouling coatings. A two-component tiecoat for foul release coatings. Parameters on this page: volume solids 56% ± 2%, dry film thickness 100 µm, theoretical spreading rate 5.60 m²/L. Comparable products from the same brand: Intercept 7000 linear polishing antifouling, Intercept 8500 LPP tin-free linear polishing polymer antifouling, Interflex 8700 SPC tin-free self-polishing copolymer antifouling.

Parameter source: International Paint INTERNATIONAL manufacturer's Technical Data Sheet (TDS) "Intersleek 7180 Foul Release Tiecoat"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids56% ± 2%
Dry Film Thickness100 µm
Theoretical Spreading Rate5.60 m²/L
VOC429 g/L (as supplied) (EPA Method 24) 308 g/kg (…
Density / Specific Gravity—
Number of ComponentsTwo-component
Mixing RatioComponent A : Component B = 4:1 (by volume)
Colour / AppearanceBXA727 red-brown
GlossMatt

Browse Similar Models by CategoryThis model belongs to: Antifouling

FAQ

How many components does Intersleek 7180 have?
Intersleek 7180 is a two-component product; use after mixing according to the mixing ratio in the "Application Data" table on this page.
What is the mixing ratio of Intersleek 7180?
The mixing ratio of Intersleek 7180 is Component A:Component B = 4:1 (by volume).
What dry film thickness is normally applied for Intersleek 7180?
The standard dry film thickness of Intersleek 7180 is 100 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Intersleek 7180?
The theoretical spreading rate of Intersleek 7180 is 5.60 m²/L; actual consumption is adjusted for substrate roughness, application losses and colour opacity.
What are the volume solids of Intersleek 7180?
The volume solids of Intersleek 7180 are 56% ± 2%.
What is the VOC of Intersleek 7180?
The VOC of Intersleek 7180 is 429 g/L (as supplied) (EPA Method 24) 308 g/kg (….
What is the gloss of Intersleek 7180?
The gloss of Intersleek 7180 is Flat.
What is the flash point of Intersleek 7180?
The flash point of Intersleek 7180 is 45°C for Component A, 21°C for Component B and 38°C after mixing; storage, transport and application follow the product Safety Data Sheet.
How is Intersleek 7180 applied?
Application method for Intersleek 7180: airless spray, brush and roller; surface preparation and the coating system are as described on this page.
Which standards does Intersleek 7180 involve?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intersleek 7180 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A two-component tie-coat for fouling-release coatings.

Intended use

A tie-coat enabling Intersleek 1000, Intersleek 1100SR and Intersleek 2120 fouling-release coatings to be applied at low temperatures over existing antifoulings.

For newbuilding, and maintenance and repair.

Product information

ColourBXA727 red-brown
Topcoat/glossMatt
Component B (curing agent)BXA728
Volume Solids56% ±2% (ISO 3233:1998)
Mixing ratioComponent A : Component B = 4:1 (by volume)
Standard film thickness100 µm dry film thickness (179 µm wet film thickness)
Theoretical Spreading RateTheoretical spreading rate 5.60 m²/L at 100 µm dry film thickness, allowing for appropriate loss factors
Application MethodsAirless spray, brush, roller
Flash PointComponent A 45 °C; Component B 21 °C; mixed 38 °C
Induction TimeNot required
Drying data10°C15°C25°C35°C
Touch dry [ISO 9117/3:2010]6 h4 h3 h2.5 h
Hard dry [ISO 9117-1:2009]20 h16 h9 h5 h
Pot life after mixing12 h10 h6 h4 h
Recoat data — see the “Limitations” sectionSubstrate Temperature
10°C15°C25°C35°C
When recoating the following productsMinimumMaximumMinimumMaximumMinimumMaximumMinimumMaximum
Intersleek 731-6 h5 days6 h5 days4 h5 days
Intersleek 7376 h5 days6 h5 days6 h5 days4 h5 days

Regulatory data

Volatile Organic Compounds429 g/L (as supplied) (EPA Method 24) 308 g/kg (as supplied liquid paint). EU Solvent Emissions Directive (Council Directive 1999/13/EC) Volatile organic compound values are typical values and are provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances.

Coating hazards GB 30981.2-S-Pb≤1000-NC; complies with GB 30981.2-2025

System and compatibility

For the paint system best suited to the surface to be protected, consult your local International Paint representative.

Surface Preparation

Applied in accordance with the standard Worldwide Marine Specifications.

All surfaces to be coated must be clean, dry and free of contaminants.

Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.

Before application of Intersleek 7180, the saponified layer of the existing antifouling coating must be removed. Removal with high-pressure fresh water at more than 3,500 psi (220 bar) and a fan jet is recommended. If the saponified layer cannot be completely removed at pressures above 3,500 psi (220 bar), pressures of up to 5,000 psi (314 bar) may be required.

Intersleek 7180 should always be applied over approved antifouling coatings and/or anticorrosive systems. Damaged areas should be prepared to the specified standard (e.g. Sa2.5 (ISO8501-1:2007)) and repaired with Intershield 300 primer. An Intersleek 7180 tiecoat system should then be applied over all surfaces.

For specific advice, consult your local International Paint representative.

Note: for the marine environment in North America, the following surface preparation standard may be used: SSPC-SP10 in place of Sa 2.5 (ISO 8501-1:2007)

Application

Mixing

The coating is supplied in two containers as one unit. Always mix the entire unit in the supplied ratio. Once mixed, use within the specified pot life.

(1) Stir the base (Component A) with a power mixer.

(2) Mix all of the base (Component A) with the curing agent (Component B) and stir thoroughly with a power mixer.

Thinner

Use International GTA220. Do not thin beyond the range permitted by local environmental regulations.

Airless Spray

Recommended nozzle size 0.46–0.66 mm (18–26 thou); total output fluid pressure at the nozzle not less than 176 kg/cm² (2500 psi)

Brush

Brush application is recommended for small areas only.

Roller application

Roller application is recommended for small areas only.

Cleaner

Interruption of work and cleaning

Do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International thinner. Once mixed, paint should not be resealed; if work is interrupted for too long, mix a fresh batch before resuming application.

All equipment should be cleaned immediately after use with International thinner. Flushing spray equipment periodically during the day is good working practice. Cleaning frequency depends on the volume sprayed, temperature and time in use (including delays). Do not exceed the pot life of the paint.

All surplus paint and empty containers must be disposed of in accordance with appropriate local regulations/laws.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.

Limitation

Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.

Apply in good weather when air and surface temperatures are above 10°C. Intersleek 7180 cannot be used at temperatures below 10°C. The temperature of the surface to be coated must be at least 3°C above the dew point. Unless otherwise specified, raise the paint temperature to 21–27°C before mixing and application to achieve optimum application performance. Unmixed paint (in tightly closed containers) should be stored protectively as specified in the "Storage" section of this product Data Sheet. The technical and application data mentioned here are intended to provide general guidelines for a paint application procedure. Test performance results come from a controlled laboratory environment, and International Paint does not claim that the published test results, or any other tests, precisely represent results obtained in all field environments. Because application, environmental and design factors vary widely, care must be taken in coating selection, performance verification or use.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
20 L16 L20 L4 L5 L

For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
20 L30.44 kg

Storage

Shelf life18 months at 25 °C. Thereafter, re-inspection is required. Store in a dry, sheltered place away from heat and sources of ignition.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — antifouling coating

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery