← Back to International brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Intercept 8500 LPP Tin-free Linear Polishing Polymer Antifouling

Quick Specs

Intercept 8500 LPP Tin-free Linear Polishing Polymer Antifouling is an antifouling coating. For newbuilding and repair and maintenance. A high-performance, low-friction, linear polishing polymer (LPP) antifouling containing proprietary Lubyon® and silyl methacrylate technology. Parameters on this page: volume solids 56% ± 2%; dry film thickness 170 µm; theoretical spreading rate 7.47–4.48 m²/L. Comparable products from the same brand: Intercept 7000 Linear Polishing Antifouling, Interflex 8700 SPC Tin-free Self-polishing Copolymer Antifouling, Intersleek 1001 Foul Release Coating.

Source: INTERNATIONAL original technical data sheet (TDS) 'Intercept 8500 LPP Tin-free Linear Polishing Polymer Antifouling'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids56% ± 2%
Dry Film Thickness170 µm
Theoretical Spreading Rate7.47–4.48 m²/L
VOC378 g/L (as supplied) (EPA Method 24); 194 g/kg (…
Density / Specific Gravity—
Number of ComponentsOne-component
Mixing RatioN/A
Colour / AppearanceLPP854 brown, LPP857 red
GlossN/A

Browse Similar Models by CategoryThis model belongs to: Antifouling

FAQ

How many components does Intercept 8500 LPP contain?
Intercept 8500 LPP is a one-component product. Stir thoroughly before use; no on-site mixing is required.
What is the mixing ratio of Intercept 8500 LPP?
Mixing ratio of Intercept 8500 LPP: not applicable.
What is the typical dry film thickness of Intercept 8500 LPP?
Typical dry film thickness of Intercept 8500 LPP: 170 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of Intercept 8500 LPP?
Theoretical spreading rate of Intercept 8500 LPP: 7.47–4.48 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Intercept 8500 LPP?
Volume solids of Intercept 8500 LPP: 56% ± 2%.
What is the VOC of Intercept 8500 LPP?
VOC of Intercept 8500 LPP: 378 g/L (as supplied) (EPA Method 24); 194 g/kg (….
What is the gloss of Intercept 8500 LPP?
Gloss of Intercept 8500 LPP: not applicable.
What is the flash point of Intercept 8500 LPP?
Flash point of Intercept 8500 LPP: 23 °C (one-component). Storage, transport and application per the product safety data sheet.
How is Intercept 8500 LPP applied?
Application method for Intercept 8500 LPP: airless spray, brush and roller; surface preparation and the coating system are as described on this page.
Which standards apply to Intercept 8500 LPP?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intercept 8500 LPP be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A high-performance, low-friction, linear polishing polymer (LPP) antifouling containing proprietary Lubyon® and silyl methacrylate technology.

Intended use

Specifically designed for ocean-going ships.

For newbuilding, and maintenance and repair.

Product information

ColourLPP854 brown, LPP857 red,
Topcoat/glossN/A
Volume Solids56% ±2% (ISO 3233:1998)
Mixing ratioN/A
Standard film thicknessMay be specified at 75–170 µm DFT (134–304 µm WFT), depending on the end use.
Theoretical Spreading RateTheoretical spreading rate at 75–125 µm DFT is 7.47–4.48 m²/L, allowing for a suitable loss factor
Application MethodsAirless spray, brush, roller
Flash PointSingle-component 23 °C
Drying data-5°C5°C25°C35°C
Touch dry [ISO 9117/3:2010]2 h90 min60 min30 min
Single coat before launching32 h16 h12 h
Multiple coats before launching60 h48 h31 h24 h
NoteFor refit and repair, if the total film thickness exceeds 250 µm, the pre-launch time must be increased as follows: 72 hours at 5 °C, 47 hours at 25 °C, 36 hours at 35 °C. For newbuilding, the single-coat pre-launch time applies to all systems.
Recoat data — see the “Limitations” sectionSubstrate Temperature
When recoating the following products-5 °C minimum-5 °C maximum5 °C minimum5 °C maximum25 °C minimum25 °C maximum35 °C minimum35 °C maximum
Intercept 8500 LPP32 h6 months24 h6 months16 h6 months16 h6 months
24 h6 months8 h6 months5 h6 months5 h6 months

Other

NoteFor newbuilding recoating, refer to the recoat data of 'Intercept 8500 LPP others'.

Regulatory data

Volatile Organic Compounds378 g/L (as supplied) (EPA Method 24); 194 g/kg (as supplied liquid paint). EU Solvent Emissions Directive (Commission Directive 1999/13/EC). VOC values are typical values provided for reference only. They may vary with factors such as colour and normal manufacturing tolerance. This product contains no organotin biocide and complies with the International Convention on the Control of Harmful Anti-fouling Systems on Ships adopted by IMO in October 2001 (IMO document AFS/CONF/26).

Certificates

When used as part of an approved scheme, the product holds the following certificates: the product is approved by the following classification societies in compliance with the International Convention on the Control of Harmful Anti-fouling Systems on Ships, 2001 (AFS 2001): • Bureau Veritas • DNV GL • Lloyd's Register. For details, consult the local representative.

System and compatibility

For the paint system best suited to the surface to be protected, consult your local International Paint representative.

Surface Preparation

Applied in accordance with the standard Worldwide Marine Specifications.

All surfaces to be coated must be clean, dry and free of contaminants.

Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.

Newbuilding: Intercept 8500 LPP should always be applied over a recommended primer. The primer surface must be dry and free of contaminants, and Intercept 8500 LPP must be applied within the specified recoat interval (refer to the relevant product data sheet). Damaged areas should be prepared to the specified standard (e.g. Sa 2.5 (ISO 8501-1:2007)) and primed before applying Intercept 8500 LPP.

Refit: Intercept 8500 LPP should always be applied over a recommended primer. The primer surface must be dry and free of contaminants, and Intercept 8500 LPP must be applied within the specified recoat interval (refer to the relevant product data sheet).

Damaged areas should be prepared to the specified standard (e.g. SSPC-SP10) and primed before applying Intercept 8500 LPP.

Repair, Intercept 8500 LPP over itself: as soon as the vessel enters the dock and before it dries, wash the whole area with dense high-pressure fresh water (3000 lb/in², 211 kg/cm²) from a fan spray gun held close to the surface. Refer to the recommended anti-corrosive primer system and apply Intercept 8500 LPP within the recoat interval specified for the primer (refer to the relevant primer product data sheet).

Applying Intercept 8500 LPP over International Paint tin-free antifouling, International Paint Intersmooth SPC antifouling or a competitor's antifouling: for special advice, consult the local International Paint representative.

Application

Mixing

This coating is a single-component product; stir thoroughly with a power mixer before application.

Thinner

Normally no thinning is required. Under extreme conditions, consult your local representative for application advice. Do not thin beyond the limits of local environmental regulations.

Airless Spray

Recommended nozzle size 0.54–0.8 mm (21–31 thou); total output fluid pressure at the nozzle not less than 190 kg/cm² (2700 psi)

Conventional spray

Conventional spray application is not recommended.

Brush

Brush application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Roller application

Roller application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Cleaner

International GTA007

Interruption of work and cleaning

Flush all equipment thoroughly with GTA007. All unused paint shall be stored in tightly closed containers. Partly filled containers may show an increase in viscosity during storage. Strain the paint before use.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.

Limitation

The service life of the coating is directly proportional to the applied thickness. Product performance depends on achieving the specified film thickness.

Intercept 8500 LPP changes colour slightly after immersion.

Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.

Apply in good weather. The temperature of the surface to be coated shall be at least 3 °C above the dew point. Unless otherwise instructed, keep the paint at 21 °C before mixing and application for optimum performance. Unmixed paint (in tightly closed containers) shall be stored as specified in the 'Storage' section of this data sheet. The technical and application data herein are intended as general guidance for establishing a coating procedure. Test results are obtained under controlled laboratory conditions; International Paint cannot assert that the published test results, or any other test results, accurately represent

Packaging Specifications

Packaging size volume; packaging

20 L20 L. For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
20 L40.4 kg

Storage

Shelf lifeAt 25 °C, a minimum of 6 months, subject to actual test results. Store in a cool, dry place away from heat and ignition sources.

Global availability

Please consult INTERNATIONAL.

Important notice

The information given in this product data sheet is not exhaustive. Anyone who uses, for any reason, any product other than those specifically recommended in this data sheet without first obtaining our written confirmation does so at their own risk as regards the suitability of the product for the intended purpose. Although we make every effort to ensure that all advice we give about the product (whether in this data sheet or otherwise) is correct, we cannot control the quality or condition of the substrate, nor the many factors affecting the application and use of this product. Accordingly, unless we specifically agree otherwise in writing, we accept no liability, to the maximum extent permitted by law, for any product performance problem arising, or for any loss or damage caused by use of the product. We therefore disclaim all warranties, express or implied, arising by operation of law or otherwise, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. All products supplied and all technical guidance provided are subject to our terms and conditions of sale. You should obtain a copy of this document and read it carefully. The information contained in this product data sheet may be amended at any time in the light of experience and of our continuing product development policy. Before using the product, it is the user's responsibility to check with the local representative that the data sheet in their possession is the latest version.

This technical data sheet is also available on our websites www.international-marine.com and www.international-pc.com, and should be consistent with this document. If there is any discrepancy between this document and the version of the technical data sheet on the website, the version on the website shall prevail.

© AkzoNobel, 2019www.international-marine.com

Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails.

Similar models from the same brand — antifouling coating

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery