ZINDN Cold Spray Zinc ZD96-2 Anti-slip is a cold galvanizing coating. Used for long-term anti-corrosion protection of steel; can be used as a single coat, or coated with a compatible heavy-duty anti-corrosion coating to play a synergistic role and meet various protection requirements. A special cold spray zinc material, a new type of heavy-duty anti-corrosion material composed of metallic zinc, activator and additives. Parameters on this page: theoretical spreading rate 0.21 kg/m². Comparable products of the same brand: ZD6310-Z4600 Cold Spray Vinyl Zinc Coating, ZD6310-Z850 Cold Spray Vinyl Zinc Coating, ZZ96-T Excellent Cold Spray Zinc.
Data source: ZINDN original Technical Data Sheet (TDS), "ZINDN Cold Spray Zinc ZD96-2 Anti-slip"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | — |
|---|---|
| Dry Film Thickness | — |
| Theoretical Spreading Rate | 0.21 Kg/m2 |
| VOC | — |
| Density / Specific Gravity | 2.7 |
| Number of Components | One-component |
| Flash Point | 47°C |
| Thinner | ZINDN Thinner |
| Colour / Appearance | A viscous zinc-grey liquid |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
ZD96-2
A special cold spray zinc material, a new type of heavy-duty anti-corrosion material composed of metallic zinc, activator and additives.
(1) ZINDN cold spray zinc can spray a zinc protection layer with a zinc content above 96% at room temperature, with excellent anti-corrosion performance;
(2) Excellent weather resistance;
(3) Strong adhesion, good overcoating performance;
(4) Convenient application, safe and environmentally friendly.
(5) Anti-slip coefficient not less than 0.55.
For long-term anti-corrosion of steel; may be used as a single coat, or overcoated with a compatible heavy-duty coating to provide synergistic protection meeting various protective requirements. An ideal material to replace or repair hot-sprayed zinc and hot-dip galvanised coatings.
| Appearance | A viscous zinc-grey liquid |
|---|---|
| density | 2.7 |
| Flash Point | 47°C |
| Theoretical Spreading Rate | 0.21 kg/m² (40 µm dry film) |
The steel surface to be coated, after shot blasting or sand blasting, shall reach cleanliness Sa 2.5 of GB/T 8923.1-2011
| level, roughness Rz = 40–70 µm; hand and power tool rust removal shall reach the GB/T 8923.1-2011 sta | ndard |
|---|
St 3 level. For old ZINDN layers or hot-dip galvanized surfaces, clean off surface dust, oil and loose layers, and roughen smooth surfaces.
| Application ambient temperature | 0 °C to 50 °C; steel plate surface temperature more than 3 °C above the dew point. |
|---|
| Thinner / Cleaning Solvent | ZINDN Thinner |
|---|
| Application method | Hand brush, roller | Air Spray | High-pressure airless spray |
| Thinner amount (by weight | 0-5 | 5-10 | 0-5 |
ratio %)
| Application method | Air Spray | High-pressure airless spray |
| %) | 0.3-0.4 | 10.0-16.0 |
Spray pressure MPa
| Ventilation, temperature, film thickness, number of coats and other factors will correspondingly affect the drying time. The typical data listed below is based on the following conditions | Good ventilation (outdoor or natural air circulation) |
|---|
| Steel plate temperature °C | 10 | 20 | 30 |
| Touch dry min | 40 | 30 | 15 |
| Cold spray zinc self-overcoating interval hours | 2 | 1 | 0.5 |
| Maximum overcoating interval hours | Unlimited, keep the surface clean and salt-free |
|---|
Use and handling of this product shall comply with the safety regulations of the relevant national or local government. The storage environment should be dry, cool and well ventilated, away from heat sources and sources of ignition. Packaging containers must be kept tightly closed. Wear protective equipment during application, ensure ventilation, avoid open flames. If it accidentally splashes into the eyes, rinse immediately with plenty of clean water and seek medical attention at a nearby hospital.
Keep out of reach of children.
The product performance and application data listed above are for reference only. Actual service environments are diverse; for any unclear points, consult Wuxi Huadong ZINDN Technology Co., Ltd. The company reserves the right to revise this data sheet without further notice.
Wuxi Huadong ZINDN Technology Co., Ltd. Version 2018A5
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.