Quick Specs

ZINDN Self-spray Zinc Aluminium ZD18-16 is a cold galvanizing coating. Can also be used for repair and maintenance of galvanized components, and is an ideal material for replacing or repairing thermally sprayed zinc and hot-dip galvanized layers. A one-component anticorrosive paint composed of fusing agent, anticorrosive base, zinc powder, aluminium powder and solvents. Parameters on this page: volume solids 30 ± 3%; dry film thickness 20/30/50 µm; theoretical spreading rate 5.5/4/2.4 m²/can. Comparable products from the same brand: ZINDN Zinc Aluminium Coating ZD83-03, ZD5180 High-solids Polyurethane Topcoat, ZD6310-N01F Epoxy Oil-resistant Static-conductive Topcoat.

Source: ZINDN original technical data sheet (TDS) 'ZINDN Self-spray Zinc Aluminium ZD18-16'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids30 ± 3%
Dry Film Thickness20/30/50 µm
Theoretical Spreading Rate2.4 m²/can
VOC—
Density / Specific Gravity1.0 ± 0.1
Number of ComponentsOne-component
Flash Point>47°C
Colour / AppearanceSilver white
GlossFlat

Browse Similar Models by CategoryThis model belongs to: Topcoat, Cold Galvanizing

ZD18-16 Self-spray Zinc Aluminium

Product description

A one-component anticorrosive paint composed of fusing agent, anticorrosive base, zinc powder, aluminium powder and solvents.

Key features

High anti-ageing performance;

High protection performance;

High decorative quality.

Flexible and simple application, fast drying.

Intended use

Used for small-area decoration and repair of steel structures, suitable for use as a topcoat with cold-spray zinc primer; also for repair and maintenance of galvanized components, and an ideal material for replacing or repairing thermally sprayed zinc and hot-dip galvanized layers.

Specification data

ColourSilver white
GlossFlat
Volume Solids30±3%
Density (kg/L)1.0±0.1

Typical film thickness and theoretical spreading rate

Dry film thickness (µm)Minimum 20Typical 30Maximum* 50
Wet film thickness (µm)67100166
Theoretical spreading rate (m²/can)5.542.4
Practical Spreading RateAllowing for a suitable loss factor

Suitable substrates and surface preparation

New steelRemove grease from the surface with a suitable cleaner, and rinse off salts and other contaminants with fresh water. Remove weld slag, and grind welds and sharp edges smooth. Abrasive blast clean to Sa 2.5 (ISO 8501-1); the ideal surface roughness is Rz 40–75 µm (medium roughness on the ISO 8503-1 comparator). Apply the primer within 4 hours of blast cleaning.
Repair of galvanised surfacesThoroughly remove grease from the surface with a suitable cleaner, wash off salts and other contaminants with high-pressure fresh water, grind small rusted areas with power tools, and touch up with this product.

Application and curing conditions

Ambient temperature for application -5 to 50 °C, air relative humidity not exceeding 95%, and the steel surface temperature shall be at least 3 °C above the dew point; outdoor application is prohibited in rain, fog, snow, strong wind and heavy dust.

In hot summer weather, guard against dry spray; provide ample ventilation during application and drying in confined spaces;

How to use the aerosol can

1. Thoroughly remove oil, grease, moisture and dust from the areas to be painted.

2. Before spraying, shake the can up, down, left and right for about two minutes so that the paint is fully mixed.

3. At about 20–30 cm from the surface to be coated, press the nozzle with the index finger and spray back and forth evenly.

4. Use multiple light sprays, applying a thin coat every two minutes, which gives a better result than a single heavy coat.

5. Before storing after use, invert the can and press the nozzle for about 3 seconds to clear residual paint and prevent clogging.

How to use the drum-pack paint

2. After opening, stir evenly and adjust to the appropriate application viscosity with thinner.

3. Air spray is recommended, about 10–15 µm per pass; two passes are preferred. Brush and roller may cause colour variation.

5. Unused paint can be sealed and stored for continued use.

Drying/curing time and recoat interval

Substrate surface temperature5°C15°C25°C35°C
Surface Dry1 h30 min15 min5 min
Hard Dry5 h2 h1 h
Minimum self-overcoating interval5 h2 h1 h
Minimum overcoating interval for sealer36 h24 h18 h12 h
Maximum recoat intervalUnlimited

Note: the above data are measured under well-ventilated conditions, at typical film thickness and 75% relative humidity, and are for reference only.

Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors.

Typical paint system

Preceding coatApply directly to steel surfaces prepared to Sa 2.5 or St 3, or to hot-dip galvanised or hot-sprayed zinc surfaces;
Subsequent coatNone.

Packaging, storage and handling

Packaging Specifications420 ml/can, or 15 kg/drum
Flash Point>47°C
Storage conditionsStore in accordance with national regulations. Keep in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed.
Shelf lifeShelf life is 2 years under good storage conditions.

Health, safety and environmental protection

This product contains flammable materials; site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).

Avoid inhaling solvent vapours and spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures for fire prevention, explosion prevention and environmental protection. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.

Waste disposal must comply with the relevant national or local regulations.

Disclaimer

The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.

Version informationPublished in June 2022; this data sheet supersedes all previous versions

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

FAQ

How many components does ZINDN Self-spray Zinc Aluminium ZD18-16 contain?
ZINDN Self-spray Zinc Aluminium ZD18-16 is a one-component product. Stir thoroughly before use; no on-site mixing is required.
What is the typical dry film thickness of ZINDN Self-spray Zinc Aluminium ZD18-16?
Typical dry film thickness of ZINDN Self-spray Zinc Aluminium ZD18-16: 20/30/50 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of ZINDN Self-spray Zinc Aluminium ZD18-16?
Theoretical spreading rate of ZINDN Self-spray Zinc Aluminium ZD18-16: 2.4 m²/can; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of ZINDN Self-spray Zinc Aluminium ZD18-16?
Volume solids of ZINDN Self-spray Zinc Aluminium ZD18-16: 30 ± 3%.
What is the gloss of ZINDN Self-spray Zinc Aluminium ZD18-16?
Gloss of ZINDN Self-spray Zinc Aluminium ZD18-16: flat.
What is the flash point of ZINDN Self-spray Zinc Aluminium ZD18-16?
The flash point of ZINDN Spray Zinc-aluminium ZD18-16 is >47 °C; storage, transport and application shall comply with the product Safety Data Sheet.
Which standards apply to ZINDN Self-spray Zinc Aluminium ZD18-16?
The technical data on this page states: ISO8501 (see application instructions on this page); ISO8503 (see application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the recommended coating system.
Where can ZINDN Self-spray Zinc Aluminium ZD18-16 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Similar models from the same brand — Topcoat, Cold Galvanizing

View all ZINDN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery