A non-slip flight deck coating complying with DEF STAN 80-134 Type 2-Coarse Texture. A high-build, two-component, spray-applied, rough three-dimensional textured epoxy non-slip topcoat. Parameters on this page: volume solids 77% ± 2%, dry film thickness 1000 µm, theoretical spreading rate 0.77 m²/L. Comparable products of the same brand: Interbond 201 - Low Temperature Epoxy Primer/Topcoat, Intercryl 559 Smooth Washable Topcoat, Intergard 7020 Abrasion-resistant Aluminium Pure Epoxy.
Data source: International original Technical Data Sheet (TDS), "Intershield 851 Epoxy Non-slip Topcoat"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 77% ± 2% |
|---|---|
| Dry Film Thickness | 1000 µm |
| Theoretical Spreading Rate | 0.77 m²/L |
| VOC | 111 g/kg (neat liquid paint). EU Solvent Emissions Directive (Commission Directive 19… |
| Density / Specific Gravity | — |
| Number of Components | Two-component |
| Mixing Ratio | Component A : Component B = 5.42:1 (by volume) |
| Colour / Appearance | ADA172 ultra deep sea grey |
| Gloss | N/A |
The manufacturer's datasheet for this model does not state the coating position or resin type, so it has not been assigned to the above categories. Browse similar products by category, orContact Usconfirm the coating system.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
A high-build, two-component, spray-applied, rough three-dimensional textured epoxy non-slip topcoat. Abrasion-resistant with good chemical resistance.
A non-slip flight deck coating complying with DEF STAN 80-134 Type 2-Coarse Texture. Can also be used on any other heavily worn decks or walkways.
| Colour | ADA172 ultra deep sea grey |
|---|---|
| Topcoat/gloss | N/A |
| Component B (curing agent) | ADA174 |
| Volume Solids | 77% ±2% (ISO 3233:1998) |
| Mixing ratio | Component A : Component B = 5.42:1 (by volume) |
| Standard film thickness | 1000 µm dry film thickness (1299 µm wet film thickness) |
| Theoretical Spreading Rate | At 1000 µm dry film thickness, the theoretical spreading rate is 0.77 m²/L, allowing an appropriate loss factor. |
| Application Methods | Conventional spray, roller |
| Flash Point | Component A 23 °C; Component B 101 °C; mixed 41 °C |
| Induction Time | Not required |
| Drying data | 10°C | 15°C | 25°C | 35°C |
| Touch dry [ISO 9117/3:2010] | 8 h | 7 h | 5 h | 2 h |
| Hard dry [ISO 9117-1:2009] | 36 h | 30 h | 16 h | 12 h |
| Pot life after mixing | 8 h | 7 h | 6 h | 4 h |
| Recoat data — see the “Limitations” section | Substrate Temperature | |||||||
| 10°C | 15°C | 25°C | 35°C | |||||
| When recoating the following products | Minimum | Maximum | Minimum | Maximum | Minimum | Maximum | Minimum | Maximum |
| Intershield 851 | 36 h | Unlimited | 30 h | Unlimited | 16 h | Unlimited | 12 h | Unlimited |
| Volatile Organic Compounds | 111 g/kg (neat liquid paint). EU Solvent Emissions Directive (Commission Directive 1999/13/EC). VOC values are typical values provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances. |
|---|---|
| DEF STAN (UK Defence Standard) | Complies with DEF STAN 80-134 Type 2 - Coarse Texture. |
For the paint system best suited to the surface to be protected, consult your local International Paint representative.
Use in accordance with the relevant "Naval Engineering Standards and Drawings".
All surfaces to be coated must be clean, dry and free of contaminants.
Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.
Newbuild/overhaul: Intershield 851 should always be applied over a recommended primer. The primer surface should be dry and free of any contaminants; Intershield 851 must be applied within the specified overcoating interval (see the relevant product data sheet). Damaged areas etc. shall be treated to the specified standard (e.g. Sa 2.5 (ISO 8501-1:2007)), and primed before applying Intershield 851.
For specific advice, consult your local International Paint representative.
Note: for the marine environment in North America, the following surface preparation standard may be used: SSPC-SP10 in place of Sa 2.5 (ISO 8501-1:2007)
The coating is supplied in two containers as one unit. Always mix the entire unit in the supplied ratio. Once mixed, use within the specified pot life.
(1) Stir the base (Component A) with a power mixer.
(2) Mix all of the base (Component A) with the curing agent (Component B) and stir thoroughly with a power mixer.
Not recommended. Only in special cases, use International GTA220 (up to 5% by volume). Do not thin beyond local environmental regulations.
Not applicable.
Recommended.
Use a 10 or 20 L pressure pot with a 12–15 mm internal diameter, 2 m long feed hose. Nozzle size 10 mm, or use a hopper gun for small areas.
Roller application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.
International GTA220
Do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International GTA220. Once mixed, a batch of paint shall not be re-sealed; if work is interrupted for a long period, remix the components before resuming.
All equipment shall be cleaned with International GTA220 immediately after use. Periodically flushing spray equipment during the working day is good practice. The frequency of cleaning depends on the quantity sprayed, temperature and elapsed time (including delays). Do not exceed the pot life of the mixed paint.
All surplus paint and empty containers must be disposed of in accordance with appropriate local regulations/laws.
If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.
All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.
Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.
Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; other regions — contact the regional office
The product does not cure adequately below 5 °C. For optimum performance, the curing temperature shall be above 10 °C.
Like all epoxy-based paints, Intershield 851 will chalk when exposed to ultraviolet light.
The chalking rate depends on the climatic conditions. Except in hot climates, chalking is limited to a thin surface layer.
Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.
Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.
In the Recoat Data section, unlimited = 'ext'. See the Marine Painting Guide — Definitions and Abbreviations available on our website.
| Packaging Specifications | Component A | Component B | ||
| Volume | Packaging | Volume | Packaging | |
| 10 L | 8.45 L | 10 L | 1.55 L | 2.5 L |
| Packaging Specifications | Packaging weight |
|---|---|
| 10 L | 23.32 kg |
| Shelf life | At 25 °C, minimum 12 months. Thereafter, re-inspection is required. Store in a dry, sheltered place away from heat and sources of ignition. |
|---|
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.