China-based coatings exporter — industrial & marine protective coatings from China's production bases

Intergard 821 Two-component Epoxy Filler

Quick Specs

For newbuilding, repair and maintenance, or in-service maintenance. Parameters on this page: volume solids 100%, dry film thickness 6000 µm, theoretical spreading rate 0.17 m²/L. Comparable models from the same brand: Interbond 201 - Low Temperature Epoxy Primer/Topcoat, Intercryl 559 Smooth Wash-resistant Topcoat, Intergard 7020 Abrasion-resistant Aluminium-pigmented Pure Epoxy Coating.

Parameter source: International INTERNATIONAL original technical data sheet (TDS) “Intergard 821 Two-component Epoxy Filler”; values such as spreading rate are converted from TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100%
Dry Film Thickness6000 µm
Theoretical Spreading Rate0.17 m²/L
VOC74 g/L (as supplied) (EPA Method 24) 126 g/kg (original…
Density / Specific Gravity—
Number of ComponentsTwo-component
Mixing RatioComponent A : Component B = 1.00:1 (by volume)
Colour / AppearanceEAA820 grey
GlossN/A

Browse Similar Models by Category

The manufacturer's datasheet for this model does not state the coating position or resin type, so it has not been assigned to the above categories. Browse similar products by category, orContact Usconfirm the coating system.

FAQ

How many components does Intergard 821 have?
Intergard 821 is a two-component product; use after mixing in the ratio given in the "Application Data" table on this page.
What is the mixing ratio of Intergard 821?
The mixing ratio of Intergard 821 is Component A:Component B = 1.00:1 (by volume).
What dry film thickness is typically applied for Intergard 821?
The conventional dry film thickness of Intergard 821 is 6000 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Intergard 821?
The theoretical spreading rate of Intergard 821 is 0.17 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour opacity.
What is the volume solids of Intergard 821?
The volume solids of Intergard 821 is 100%.
What is the VOC of Intergard 821?
The VOC of Intergard 821 is 74 g/L (as supplied) (EPA Method 24) 126 g/kg (original…
What is the gloss of Intergard 821?
The gloss of Intergard 821 is Not applicable.
What is the flash point of Intergard 821?
The flash point of Intergard 821 is Component A 65 °C; Component B 62 °C; after mixing 62 °C. Storage, transport and application shall comply with the product safety data sheet.
How is Intergard 821 applied?
Application method for Intergard 821: float application; surface preparation and the coating system are as described on this page.
Which standards does Intergard 821 involve?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intergard 821 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A two-component epoxy filler.

Intended use

Used as an anti-anodic effect layer,and as a filler for pitting corrosion on steel.

For newbuilding, maintenance and repair, or in-service maintenance.

Product information

ColourEAA820 grey
Topcoat/glossN/A
Component B (curing agent)EAA821
Volume Solids100% (ISO 3233:1998)
Mixing ratioComponent A : Component B = 1.00:1 (by volume)
Standard film thickness6000 µm dry film thickness (6000 µm wet film thickness) used as an anti-anodic effect layer; up to 20,000 µm can be used as a filler
Theoretical Spreading RateAt 6000 µm dry film thickness, the theoretical spreading rate is 0.17 m²/L; an appropriate loss factor is permitted
Application MethodsTrowel
Flash PointComponent A 65 °C; Component B 62 °C; after mixing 62 °C
Induction TimeNot required
Drying data5°C10°C23°C35°C
Touch dry [ISO 9117/3:2010]10 h9 h6 h2 h
Hard dry [ISO 9117-1:2009]48 h42 h24 h12 h
Pot life after mixing4 h3 h60 min20 min
Recoat data — see the “Limitations” sectionSubstrate Temperature
5°C10°C23°C35°C
When recoating the following productsMinimumMaximumMinimumMaximumMinimumMaximumMinimumMaximum
Intergard 82148 h7 days42 h5 days24 h48 h12 h24 h
NoteIntergard and Intertuf products may be applied as subsequent coats; for specific recommendations, consult International (International Paint).

Regulatory data

Volatile Organic Compounds74 g/L (as supplied) (EPA Method 24) 126 g/kg (as supplied liquid paint). EU Solvent Emissions Directive (Council Directive 1999/13/EC) 48 g/L China National Standard GB23985. VOC values are typical values and are provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances.

Coating hazards GB 30981.2-S-Pb≤1000-NC; complies with GB 30981.2-2025

System and compatibility

For the paint system best suited to the surface to be protected, consult your local International Paint representative.

Surface Preparation

Applied in accordance with the standard Worldwide Marine Specifications.

All surfaces to be coated must be clean, dry and free of contaminants.

Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.

Anti-anodic effect layer. Newbuilding/overhaul: where required, remove weld spatter and grind welds and sharp edges.

Abrasive blast clean to Sa2.5 (ISO 8501-1:2007). If oxidation has occurred between blasting and application of Intergard 821, the surface shall be re-blasted to the specified pictorial standard.

Repair blast clean bare steel areas to Sa2.5 ISO 8501:1. Sand or scrape surrounding damaged paint film back to sound edges. Feather exposed edges of existing Intergard 821 to provide an adhesion base. Apply Intergard 821 overlapping onto the abraded area.

Pitting: blast to Sa2.5 ISO 8501-1:2001. If effective cleaning cannot be achieved by blasting, mechanically grind the pits with a suitable corundum grinding head.

Apply a suitable primer before oxidation occurs.

Apply Intergard 821 within the specified primer overcoating interval (refer to the relevant primer product data sheet).

Ensure the area is clean and dry before application of Intergard 821.

For specific advice, consult your local International Paint representative.

Note: for the marine environment in North America, the following surface preparation standard may be used: SSPC-SP10 in place of Sa 2.5 (ISO 8501-1:2007)

Application

Other trowel or spread application

Mixing

Mix EAA820 and EAA821 at a volume ratio of 1:1 and stir thoroughly until the colour is uniform. Mix only the quantity of paint that can be used within the pot life.

Thinner

Do not thin!

Airless Spray

N/A

Conventional spray

N/A

Brush

N/A

Roller application

N/A

Cleaner

Interruption of work and cleaning

Monitor the paint condition closely; do not exceed the pot life. Clean all equipment immediately after use with International GTA822.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.

Limitation

The product will not cure adequately below 5 °C. For optimum properties, the curing temperature shall be above 10 °C. Under damp conditions, sweating may appear on the Intergard 821 surface and must be washed off with fresh water before overcoating.

Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.

Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
5 L2.5 L2.5 L5 L

For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
5 L4.42 kg

Storage

Shelf life24 months at 25 °C, after which re-inspection is required. Store in a dry, sheltered place away from heat sources and ignition sources.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — Same brand

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

Factory item number list (1 in total)

The factory item numbers for Intergard 821 two-component epoxy filler are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.

Item No.Colour / colour codePackaging Specifications
EAA820Grey10 L

This model has a total of1item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.

China production baseIndustrial & marine coatingsWorldwide delivery