Used for maintenance of conventional alkyd systems in above-water areas. A single-component alkyd primer containing anti-corrosive pigments. Parameters on this page: volume solids 52% ± 2%, dry film thickness 75 µm, theoretical spreading rate 6.93 m²/L. Comparable products of the same brand: Interbond 201 - Low Temperature Epoxy Primer/Topcoat, Intercryl 559 Smooth Washable Topcoat, Intergard 7020 Abrasion-resistant Aluminium Pure Epoxy.
Data source: International original Technical Data Sheet (TDS), "Interprime 128 Single-component Alkyd Primer"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 52% ± 2% |
|---|---|
| Dry Film Thickness | 75 µm |
| Theoretical Spreading Rate | 6.93 m²/L |
| VOC | 387 g/L (neat) (EPA Method 24) 260 g/kg(… |
| Density / Specific Gravity | — |
| Number of Components | One-component |
| Mixing Ratio | N/A |
| Colour / Appearance | CPA129 red |
| Gloss | Matt |
The manufacturer's datasheet for this model does not state the coating position or resin type, so it has not been assigned to the above categories. Browse similar products by category, orContact Usconfirm the coating system.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
A single-component alkyd primer containing anti-corrosive pigments.
Used for maintenance of conventional alkyd systems in above-water areas.
Used for in-service maintenance.
| Colour | CPA129 red |
|---|---|
| Topcoat/gloss | Matt |
| Component B (curing agent) | N/A |
| Volume Solids | 52% ±2% (ISO 3233:1998) |
| Mixing ratio | N/A |
| Standard film thickness | 75 µm dry film thickness (144 µm wet film thickness) |
| Theoretical Spreading Rate | At 75 µm dry film thickness, the theoretical spreading rate is 6.93 m²/L, allowing an appropriate loss factor. |
| Application Methods | Airless spray, brush, conventional spray, roller |
| Flash Point | Single component 35 °C |
| Drying data | -5°C | 5°C | 25°C | 35°C |
| Touch dry [ISO 9117/3:2010] | 3 h | 2 h | 60 min | 45 min |
| Hard dry [ISO 9117-1:2009] | 72 h | 36 h | 18 h | |
| Recoat data — see the “Limitations” section | Substrate Temperature |
|---|
| When recoating the following products | -5 °C minimum | -5 °C maximum | -5 °C minimum | 5 °C maximum | 25 °C minimum | 25 °C maximum | 35 °C minimum | 35 °C maximum |
| Interlac 665 | 24 h | 28 days | 24 h | 28 days | 16 h | 28 days | 16 h | 28 days |
| Interprime 128 | 24 h | 28 days | 24 h | 28 days | 16 h | 28 days | 16 h | 28 days |
| Volatile Organic Compounds | 387 g/L (neat) (EPA Method 24) 260 g/kg (neat liquid paint). EU Solvent Emissions Directive (Commission Directive 1999/13/EC). VOC values are typical values provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances. |
|---|
For the paint system best suited to the surface to be protected, consult your local International Paint representative.
Applied in accordance with the standard Worldwide Marine Specifications.
All surfaces to be coated must be clean, dry and free of contaminants.
Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.
In-service maintenance: treat the area to be repaired to at least St 2 (ISO 8501-1:1998). Higher-level surface preparation using abrasive blasting or ultra-high-pressure water jetting to Sa 2 (ISO 8501-1:2001) or HB2M (International Paint ultra-high-pressure water jetting standard) will improve product performance.
Sand or scrape the area around damaged film to a firm edge.
Before applying Interprime 128, ensure the area is clean and dry.
The primer overlaps the existing coating by about 2–3 cm.
For specific advice, consult your local International Paint representative.
Note: for the marine environment in North America, the following surface preparation standards may be used: SSPC-SP2 instead of St 2 (ISO 8501-1:2007); SSPC-SP6 instead of Sa 2 (ISO 8501-1:2007)
This coating is a single-component product; stir thoroughly with a power mixer before application.
Not recommended. Only in special cases, use International GTA004. Do not thin beyond local environmental regulations.
Recommended nozzle tip size 0.46–0.53 mm (18–21 thou); total fluid pressure at the nozzle not less than 176 kg/cm² (2500 psi)
Suitable.
Use suitable dedicated equipment. Thinning may be required.
When applying Interprime 128 by brush, it may be necessary to apply multiple coats to achieve the specified total dry film thickness.
When applying Interprime 128 by roller, multiple coats may be required to achieve the specified total dry film thickness.
Flush all equipment thoroughly with International GTA004 or International GTA007. All unused paint shall be stored in tightly closed containers. Containers not completely filled may develop surface skinning and/or increased paint viscosity after storage. Paint should be filtered before use.
If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.
All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.
Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.
Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; other regions — contact the regional office
Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.
Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.
| Packaging Specifications | Component A volume; packaging |
|---|---|
| 20 L | 20 L. For other packaging sizes, consult International Paint. |
| Packaging Specifications | Packaging weight |
|---|---|
| 20 L | 31.6 kg |
| Shelf life | At 25 °C, minimum 24 months. Thereafter, re-inspection is required. Store in a dry, sheltered place away from heat and sources of ignition |
|---|