Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600 is a glass flake coating in the epoxy system. Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600 is recommended for structures long-term exposed to abrasive and corrosive environments, such as steel trusses and pile foundations of offshore photovoltaic modules. Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600 is a self-priming high-build glass flake epoxy coating with high impact and abrasion resistance. Parameters on this page: volume solids 90 ± 2%; dry film thickness 400 µm; theoretical spreading rate 2.2 m²/L.
Source: HEMPEL original technical data sheet (TDS) 'Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 90 ± 2% |
|---|---|
| Dry Film Thickness | 400 µm |
| Theoretical Spreading Rate | 2.2 m²/L |
| VOC | 156 g/L (China) |
| Density / Specific Gravity | 1.5 kg/L |
| Number of Components | Two-component |
| Flash Point | 28°C |
| Thinner | HEMPEL's Thinner 08450 |
| Colour / Appearance | Pale grey 11154 |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Heavy-duty Epoxy 600
Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600 is a self-priming high-build glass flake epoxy coating with high impact and abrasion resistance. This product protects structures from harsh corrosive environments. Suitable for early water immersion. Used in a high-build single-coat system, effectively improving application efficiency and reducing process complexity.
Hempel's Glass Flake Reinforced Heavy-duty Anticorrosive Epoxy Paint 600 is recommended for structures long-term exposed to abrasive and corrosive environments, such as steel trusses and pile foundations of offshore photovoltaic modules. The product can also serve as an efficient maintenance solution in similar environments.
| Product safety | Flash point 28 °C |
|---|
| Regulations | Value |
| European Union | 156 g/L |
| USA (coatings) | 156 g/L |
| USA (regulatory) | 156 g/L |
| Canada | 156 g/L |
| China | 156 g/L |
| Hong Kong | 156 g/L |
| South Korea | 156 g/L |
Subject to specific legislation; see the explanatory notes on the Hempel website hempel.com or your local Hempel website. This product complies with the VOC requirements of national mandatory or recommended standards; consult the company representative for details.
Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.
For professional use only.
| Product code | 45350 |
|---|---|
| Product components | Base 45359 |
Hardener 95505
| Standard colour / code | Pale grey 11154 |
|---|
Light grey 11154
| Gloss | Semi-gloss |
|---|---|
| Volume solids | 90 ± 2% |
| density | 1.5 kg/L |
| Recommended dry film thickness | 400 µm |
For further details, refer to the separate Hempel document Surface Preparation Guide.
Base 45359 : Hardener 95505 (4:1 by volume)
| Thinner | HEMPEL's Thinner 08450 |
|---|---|
| Cleaning solvent | HEMPEL's Tool Cleaner 99610 |
| Product temperature | 10°C | 20°C | 30°C |
| Pot Life | 2 h | 1 h | ½ h |
| Tools | Maximum thinning volume | Application parameters |
| Airless Spray | 5% | Nozzle pressure: 25 MPa; tip size: 0.64–0.79 mm |
| Brush/roller | 8% | Not applicable. |
If brush or roller application is used, multiple coats are required to achieve the specified dry film thickness. For brush or roller application, a suitable thinner or brushing agent may be used as required. Spray parameters are indicative and may be adjusted to site conditions. Pressure figures apply to material at 20 °C. (*For other application methods, consult the company representative.)
| Specification range | Low | High | Recommended |
| Dry Film Thickness | 200 µm | 600 µm | 400 µm |
| Wet Film Thickness | 222 µm | 667 µm | 444 µm |
| Theoretical Spreading Rate | 4.5 m²/L | 1.5 m²/L | 2.2 m²/L |
Depending on the end use and service area, the product may be specified at film thicknesses other than those indicated. This will alter the spreading rate, drying and curing times and recoat interval.
| Surface temperature | -5°C | 10°C | 20°C | 30°C |
| Touch Dry | 15 h | 6 | 3 | 1½ |
| Hard Dry | 43 h | 14 | 7 | 4 |
| Fully cured | 12 days | 9 | 5 | 3½ |
Dry film thickness measured at 400 µm under standard conditions; see Hempel's explanatory notes.
Hempel's specifications supersede all guidance shown in the recoat table.
| Product name | 10°C | 20°C | 30°C | 40°C | |
| Atmospheric, severe | |||||
|---|---|---|---|---|---|
| HEMPEL Glass Flake Reinforced Heavy-Duty Epoxy 600 | Minimum | 10 h | 5 h | 4 h | 2½ h |
| Maximum | 60 days | 30 days | 22 days | 15 days | |
| Immersion | |||||
| HEMPEL Glass Flake Reinforced Heavy-Duty Epoxy 600 | Minimum | 12 h | 6 h | 4½ h | 3 h |
| Maximum | 60 days | 30 days | 22 days | 15 days | |
- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.
| Ambient temperature | 25°C |
| Binder | 24 months |
| Curing agent | 12 months |
When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. For advice, consult Hempel.
- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Dry Film Thickness | 1 µm | |
| GWP (Global Warming Potential) | 6 g CO₂e/m² |
Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².
The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.
Calculated based on the standard colours defined in this PDS. Values may vary with colour.
For further information, refer to the Hempel website (https://www.hempel.com/service-and-support/technical-guidelines) or your local Hempel website:
| Number | Document description | Location/Notes |
| 3. | PDS | This document |
datasheet, which is also available for download at www.hempel.com.
This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):
| 1. | Technical declaration | Provides one-off specific advice for the requirements of a specific project |
| 2. | Specifications | Issued for specific projects only |
| 4. | Explanatory notes to the PDS | Available for download at www.hempel.com, containing information related to product test parameters |
| 5. | Application guide | If available, provided at www.hempel.com |
| 6. | General technical guidelines (e.g. application and surface preparation) |
If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.