HEMPEL Pure Epoxy Glass Flake Paint 47702 belongs to glass flake paint, epoxy coating system. The product can also be applied under conditions requiring rapid recoating and handling, at temperatures as low as -10°C. HEMPEL Pure Epoxy Glass Flake Paint 47702 is a two-component high-build pure epoxy paint reinforced with glass flake; after curing it forms a hard, wear-resistant and impact-resistant coating with good seawater resistance. Parameters on this page: volume solids 77 ± 2%, dry film thickness 125 µm, theoretical spreading rate 6.1 m²/L. Similar models from the same brand for comparison: HEMPEL Glass Flake Reinforced Heavy-Duty Epoxy Paint 600, HEMPEL Glass Flake Super Epoxy Paint 35870, HEMPEL Super Strength Glass Flake Epoxy Paint 35840.
Parameter source: HEMPEL original technical data sheet (TDS) HEMPEL Pure Epoxy Glass Flake Paint 47702; values such as spreading rate are converted from TDS parameters for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 77 ± 2% |
|---|---|
| Dry Film Thickness | 125 µm |
| Theoretical Spreading Rate | 6.1 m²/L |
| VOC | 238 g/L (China) |
| Density / Specific Gravity | 1.5 kg/L |
| Number of Components | Two-component |
| Flash Point | 25°C |
| Thinner | HEMPEL's Thinner 08450 |
| Colour / Appearance | Venetian Red 50630 ** |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
HEMPEL Pure Epoxy Glass Flake Paint 47702 is a two-component high-build pure epoxy paint reinforced with glass flake; after curing it forms a hard, wear-resistant and impact-resistant coating with good seawater resistance.
As a high-performance coating with self-priming properties or an intermediate coating system, for atmospheric or underwater exposure in abrasive and corrosive environments such as cargo holds, hulls, working decks or steel structures requiring low VOC, fast drying and high solids. The product can also be applied under conditions requiring rapid recoating and handling, at temperatures as low as -10°C.
| Product safety | Flash point 25 °C |
|---|
| Regulations | Value |
| European Union | 238 g/L |
| USA (coatings) | 238 g/L |
| USA (regulatory) | 238 g/L |
| Canada | 238 g/L |
| China | 238 g/L |
| Hong Kong | 238 g/L |
| South Korea | 238 g/L |
Subject to specific legislation; see the explanatory notes on the Hempel website hempel.com or your local Hempel website. VOC values may vary with colour; refer to Section 9 of the Safety Data Sheet. This product complies with the VOC requirements of national mandatory or recommended standards; consult the company representative for details.
Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.
For professional use only.
| Product code | 47702 |
|---|---|
| Product components | Base 47708 |
Curing agent 97702
| Standard colour* / code | Venetian Red 50630 ** |
|---|
Brown-red 50630
| Gloss | Flat |
|---|---|
| Volume solids | 77 ± 2% |
| density | 1.5 kg/L |
| Recommended dry film thickness | 125 µm |
For further details, refer to the separate Hempel document Surface Preparation Guide.
Base 47708 : curing agent 97702 (4 : 1 by volume)
Stir thoroughly before use.
| Thinner | HEMPEL's Thinner 08450 |
|---|---|
| Cleaning solvent | HEMPEL's Tool Cleaner 99610 |
HEMPEL's Thinner 08450
| Product temperature | 10°C | 20°C |
| Pot life (spray) | 2 h | 1 h |
| Pot life (brush) | 3 h | 1½ h |
| Tools | Maximum thinning volume | Application parameters |
| Airless Spray | 5% | Nozzle pressure: 25 MPa Nozzle tip size: 0.53–0.69 mm |
| Brush/roller | 5% | Not applicable. |
If brush or roller application is used, several coats may be required to achieve the specified dry film thickness. Spray parameters are indicative and may be adjusted to suit site conditions. Pressure figures apply to the material at 20 °C. (*For other application methods, consult the company representative.)
| Specification range | Low | High | Recommended |
| Dry Film Thickness | 125 µm | 200 µm | 125 µm |
| Wet Film Thickness | 163 µm | 261 µm | 163 µm |
| Theoretical Spreading Rate | 6.1 m²/L | 3.8 m²/L | 6.1 m²/L |
Depending on the end use and service area, the product may be specified at film thicknesses other than those indicated. This will alter the spreading rate, drying and curing times and recoat interval. To achieve optimum performance, avoid excessive film thickness.
| Surface temperature | -10°C | 0°C | 20°C | 40°C |
| Touch Dry | 120 min | 60 | 45 | 15 |
| Hard Dry | 24 h | 12 | 3 | 1 |
| Fully cured | 45 days | 22 | 5 | 2 |
Measured at 125 µm dry film thickness under standard conditions; see Hempel's explanatory notes.
Hempel's specifications supersede all guidance shown in the recoat table.
| Product name | -10°C | 0°C | 20°C | 30°C | |
| Atmospheric, moderate | |||||
|---|---|---|---|---|---|
| HEMPEL Pure Epoxy Glass Flake 47702 | Minimum | 27 h | 12 h | 3 h | 2½ h |
| Maximum | 90 days | 56 days | 14 days | 10 days | |
| HEMPEL's Polyurethane Mastic Topcoat 55610 | Minimum | 27 h | 12 h | 3 h | 2½ h |
| Maximum | 90 days | 40 days | 10 days | 7½ days | |
| Immersion | |||||
| HEMPEL Pure Epoxy Glass Flake 47702 | Minimum | 36 h | 16 h | 4 h | 3 h |
| Maximum | 90 days | 56 days | 14 days | 10 days | |
For products of the same generic chemical composition, recoat times are for reference only.
For further information, refer to Hempel's specifications.
- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.
| Ambient temperature | 25°C |
| Binder | 36 months |
| Curing agent | 12 months |
When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. For advice, consult Hempel.
- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Dry Film Thickness | 1 µm | |
| GWP (Global Warming Potential) | 6.8 g CO₂e/m² |
Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².
The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.
Calculated based on the standard colours defined in this PDS. Values may vary with colour.
For further information, refer to the Hempel website (https://www.hempel.com/service-and-support/technical-guidelines) or your local Hempel website:
| Number | Document description | Location/Notes |
| 3. | PDS | This document |
datasheet, which is also available for download at www.hempel.com.
This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):
| 1. | Technical declaration | Provides one-off specific advice for the requirements of a specific project |
| 2. | Specifications | Issued for specific projects only |
| 4. | Explanatory notes to the PDS | Available for download at www.hempel.com, containing information related to product test parameters |
| 5. | Application guide | If available, provided at www.hempel.com |
| 6. | General technical guidelines (e.g. application and surface preparation) |
If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.