Quick Specs

6182H CMP NOVA 5000 BARRIER Solvent-free Epoxy Mastic belongs to Epoxy. CMP NOVA 5000 BARRIER is a solvent-free epoxy mastic, qualified in accordance with MSC.1/Cric.1300 and MSC.1/Cric.1399 for use as a protective coating in ballast tanks and cargo oil tanks. Parameters on this page: volume solids 100%, dry film thickness 300 µm, theoretical spreading rate 0.3 L/m2. Comparable models from the same brand: 5006 ALP 500 Epoxy, 5055 BANNOH 500 Epoxy, 5055D BANNOH 500 AC Epoxy.

Parameter source: CMP original technical data sheet (TDS) "6182H CMP NOVA 5000 BARRIER Solvent-free Epoxy Mastic"; values such as spreading rate are converted from TDS parameters and are for model selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100%
Dry Film Thickness300 µm
Theoretical Spreading Rate0.3 L/m2
VOC195 g/L
Density / Specific Gravity2.16 g/mL
Number of ComponentsTwo-component
ThinnerEPOXY THINNER (for cleaning only)
Mixing RatioBase : curing agent = 55:45 (by volume)
Colour / AppearanceGrey

Browse Similar Models by CategoryThis model belongs to: Epoxy

CMP NOVA 5000 BARRIER is a solvent-free epoxy mastic, qualified in accordance with MSC.1/Cric.1300 and MSC.1/Cric.1399 for use as a protective coating in ballast tanks and cargo oil tanks. It provides good seawater resistance and high crude oil resistance; it also has excellent adhesion and bonds to simply prepared and/or slightly damp surfaces.

Technical data

TypeSolvent-free epoxy mastic
UseSuitable for ballast tanks, void spaces and similar spaces.

Documents

Mixing RatioBase : curing agent = 55:45 (by volume)
ColourGrey
Flash PointBase >=250 °C Hardener 155 °C
Density2.16 g/mL
Volume Solids100%
Volatile organic compound content195 g/L
Theoretical spreading rate0.3 L/m2
ThicknessWFT 300 µm
Dry film300 µm

(DFT 300 µm)

Temperature5 °C10 °C20 °C30 °C
Drying TimeSurface Dry48 h8 h4 h2 h
Hard Dry72 h24 h12 h8 h
Recoat intervalAt least72 h24 h12 h8 h
At most7 days7 days
Pot life1.5 h1 h40 min30 min
Minimum launching time60 h18 h8 h6 h

Application conditions

Application methodBrush, roller, knife, trowel, hand application
Weather: temperatureMinimum 5 °C
HumidityMaximum 85% RH
ThinnerEPOXY THINNER (for cleaning only)
ThinningNone recommended

Recommended surface preparation

High-pressure water jet (pressure above 15000 psi recommended) or power tools to Sa2

(ISO 8501-12007) to clean the damaged areas. Remove salt and other contaminants.

CMP NOVA 5000 BARRIER may be applied to undried surfaces.

Preceding coat-
Subsequent coat-
PackagingTwo-component

Note: 1. Stir the base with a stirrer until uniform, then add the curing agent and mix with the base using a powerful stirrer. Then add an appropriate amount of thinner and mix.

2 Store the paint in a cool place to ensure the paint is at a suitable temperature. The temperature rise caused by mixing large quantities of paint shortens the pot life.

3 If the coating surface is exposed to direct sunlight, apply the subsequent coat as soon as possible after the minimum overcoating interval.

4 Density, volume solids and VOC content are theoretical values calculated without thinner.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

FAQ

How many components does 6182H CMP NOVA 5000 BARRIER have?
6182H CMP NOVA 5000 BARRIER is a two-component product. Mix in accordance with the mixing ratio given in the "Coating Data" table on this page before use.
What is the mixing ratio of 6182H CMP NOVA 5000 BARRIER?
The mixing ratio of 6182H CMP NOVA 5000 BARRIER is Base : Curing agent = 55:45 (by volume).
What DFT is typically applied for 6182H CMP NOVA 5000 BARRIER?
6182H CMP NOVA 5000 BARRIER is typically applied at a DFT of 300 µm; the specific value is determined by the coating scheme and design requirements.
What is the theoretical spreading rate of 6182H CMP NOVA 5000 BARRIER?
The theoretical spreading rate of 6182H CMP NOVA 5000 BARRIER is 0.3 L/m2; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of 6182H CMP NOVA 5000 BARRIER?
The volume solids of 6182H CMP NOVA 5000 BARRIER is 100%.
What is the VOC of 6182H CMP NOVA 5000 BARRIER?
The VOC of 6182H CMP NOVA 5000 BARRIER is 195 g/L.
Which thinner is used for 6182H CMP NOVA 5000 BARRIER?
Recommended thinner for 6182H CMP NOVA 5000 BARRIER: EPOXY THINNER (for cleaning only).
What is the flash point of 6182H CMP NOVA 5000 BARRIER?
The flash point of 6182H CMP NOVA 5000 BARRIER is base >=250 °C, curing agent 155 °C; storage, transport and application follow the product safety data sheet.
How long does 6182H CMP NOVA 5000 BARRIER take to dry?
Drying time of 6182H CMP NOVA 5000 BARRIER under standard conditions: drying time touch dry; actual values are affected by temperature, film thickness and ventilation.
Which standards apply to 6182H CMP NOVA 5000 BARRIER?
The technical data on this page states: ISO 8501 (see application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the recommended coating system.
Where can 6182H CMP NOVA 5000 BARRIER be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Similar models from the same brand — epoxy coating

View all CMP models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery