6072 CLEANKEEP 5000 Solvent-free Epoxy Paint is an epoxy paint. CLEANKEEP 5000 is a solvent-free epoxy paint that can be used as a protective coating for potable water tanks. Parameters on this page: volume solids 100% (ISO: 3233), dry film thickness 300 µm, theoretical spreading rate 0.3 L/m². Comparable products of the same brand: 5006 ALP 500 Epoxy Paint, 5055 BANNOH 500 Epoxy Paint, 5055D BANNOH 500 AC Epoxy Paint.
Data source: CMP original Technical Data Sheet (TDS), "6072 CLEANKEEP 5000 Solvent-free Epoxy Paint"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% (ISO: 3233) |
|---|---|
| Dry Film Thickness | 300 µm |
| Theoretical Spreading Rate | 0.3 L/m2 |
| VOC | 123 g/L (Method 24) |
| Density / Specific Gravity | 1.49 g/mL (ISO: 2811) |
| Number of Components | Two-component |
| Thinner | EPOXY THINNER A (for cleaning only) |
| Mixing Ratio | Base : curing agent = 82:18 (by volume) |
| Colour / Appearance | Cream yellow, light grey |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
CLEANKEEP 5000 is a solvent-free epoxy paint that can be used as a protective coating for potable water tanks. During application there is no need to worry about fire or organic solvent toxicity.
As it contains no heavy metals, it is safe and hygienic. Using airless spray, this product achieves a high film thickness in a single coat (500 µm). The coating surface is hard, glossy and smooth.
| Type | Solvent-Free Epoxy |
|---|---|
| Use | May be used for fresh water tanks, potable water tanks and light water tanks. |
| Mixing Ratio | Base : curing agent = 82:18 (by volume) |
|---|---|
| Colour | Cream yellow, light grey |
| Flash Point | Base = 135 °C, Hardener = 126 °C |
| Density | 1.49 g/mL (ISO: 2811) |
| Volume Solids | 100% (ISO: 3233) |
| Volatile organic compound content | 123 g/L (Method 24) |
| Theoretical spreading rate | 0.3 L/m2 |
| Thickness | WFT 300 µm, DFT 300 µm |
| Temperature | 10 °C | 20 °C | 30 °C | |
| Drying Time | Surface Dry | 45 h | 18 h | 11 h |
| Hard Dry | 4 days | 32 h | 24 h | |
| Recoat interval | At least | 4 days | 32 h | 24 h |
| At most | 14 days | 14 days | ||
| Pot life | 1.5 h | 1 h | 45 min | |
| Application method | Airless spray, brush, roller |
|---|---|
| Weather: temperature | Minimum 10 °C |
| Humidity | Maximum 85% RH; steel temperature at least 3 °C above the dew point |
| Airless spray: viscosity | 3.0-4.0s |
| Nozzle | (Graco)619-721 |
| Paint output pressure | 23.5-33.4 Mpa |
| Spray gun speed | 60–80 cm/s |
| Thinner | EPOXY THINNER A (for cleaning only) |
| Thinning | -% by volume |
| Newbuilding | Follow the shipyard standards. Consult your CMP representative for advice. |
|---|---|
| Repair and maintenance | Remove oil, grease and the like. Remove salts and other contaminants with high-pressure fresh water, then dry completely. |
| Remove damaged areas by abrasive to at least Sa2 (ISO 8507-1 | 2007), or by power tool to |
| St3(ISO 8507-1 | 2007). |
| Rinse with water | Consult your CMP representative for advice. |
The type and degree depend on the actual condition of the material and the required performance.
Use standards consistent with the Worldwide Marine Specifications.
| Preceding coat | CERABOND 2000, EPICON ZINC RICH PRIMER B-2,CLEANKEEP 5000 HOLDING PRIMER |
|---|---|
| Subsequent coat | - |
| Packaging | Two-component |
Note: 1. Stir the base with an electric stirrer to a uniform state, then thoroughly stir all of the curing agent with the base. Finally add an appropriate amount of thinner and mix thoroughly.
2. The pot life is short; mix only the amount needed.
3. In winter, heating the paint and the air in the tank is recommended.
4 Potable water quality certified by the following tests:
| -Test of Effect on Water Quality/BS 2000 | 6920-WRAS (UK) |
|---|---|
| -SS375 | 1994 - Singapore |
| -Ministry of Health Circular no.102/78 | 2001 - Italy - Hiroshima City Research Laboratory of Public Health - Japan. 5 Density, volume solids and VOC content are theoretical calculated values excluding thinner. The values vary depending on colour, production process and local regulations. |
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.