← Back to CMP brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

6033 EPICON T-800 HS High-build Epoxy Phenolic Tank Coating

Quick Specs

6033 EPICON T-800 HS High-build Epoxy Phenolic Tank Lining is an epoxy coating. One coat by airless spray can achieve a dry film thickness of 100–150 µm. Parameters on this page: volume solids 77 ± 2% [by volume], dry film thickness 100–200 µm, theoretical spreading rate 0.13–0.26 L/m². Comparable products from the same brand: 6037 EPICON T-800 High-build Epoxy Phenolic Tank Lining, 6037B EPICON T-800 QD High-build Epoxy Phenolic Tank Lining, 6035 EPICON T-800 HOLDING PRIMER Epoxy Phenolic Resin Temporary Anti-corrosive Primer.

Parameter source: CMP original technical data sheet (TDS) "6033 EPICON T-800 HS High-build Epoxy Phenolic Tank Lining"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids77 ± 2% [by volume]
Dry Film Thickness100–200 µm
Theoretical Spreading Rate0.13-0.26 L/m2
VOC268 g/L
Density / Specific Gravity1.47 g/ml
Number of ComponentsTwo-component
ThinnerEPOXY THINNER B
Mixing RatioBase : curing agent = 83:17 (by volume)
Colour / AppearanceGrey, light grey, red-brown

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does 6033 EPICON T-800 HS have?
6033 EPICON T-800 HS is a two-component product. Mix according to the mixing ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of 6033 EPICON T-800 HS?
The mixing ratio of 6033 EPICON T-800 HS is Base : Hardener = 83:17 (by volume).
What dry film thickness is typically applied for 6033 EPICON T-800 HS?
The conventional dry film thickness of 6033 EPICON T-800 HS is 100–200 µm; the specific value shall be determined according to the coating system and design requirements.
What is the theoretical spreading rate of 6033 EPICON T-800 HS?
The theoretical spreading rate of 6033 EPICON T-800 HS is 0.13–0.26 L/m²; the actual consumption shall be adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of 6033 EPICON T-800 HS?
The volume solids of 6033 EPICON T-800 HS is 77 ± 2% [by volume].
What is the VOC of 6033 EPICON T-800 HS?
The VOC of 6033 EPICON T-800 HS is 268 g/L.
What thinner is used for 6033 EPICON T-800 HS?
Recommended thinner for 6033 EPICON T-800 HS: EPOXY THINNER B.
What is the flash point of 6033 EPICON T-800 HS?
The flash point of 6033 EPICON T-800 HS is Base 24.0 °C, Hardener 10.0 °C. Storage, transportation and application shall be carried out in accordance with the product safety data sheet.
How long does 6033 EPICON T-800 HS take to dry?
Drying time of 6033 EPICON T-800 HS under standard conditions: drying time touch dry; actual drying is affected by temperature, film thickness and ventilation.
What standards are involved for 6033 EPICON T-800 HS?
As recorded in the technical data on this page: remove the damaged areas by abrasive means to at least the Sa2 1/2 standard (ISO 8507-1 2007), or with power tools to St3 (ISO 8507-1 2007). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can 6033 EPICON T-800 HS be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

EPICON T-800 HS is a high-build epoxy phenolic coating with excellent physical properties such as strong adhesion, tough film and abrasion resistance, and excellent chemical resistance to salt water, fresh water, petroleum products, crude oil, alkaline substances and weak acids. It is suitable as a protective coating for the interior of tanks. One coat by airless spray can achieve a dry film thickness of 100–150 µm.

Technical data

TypeHigh-Build Epoxy Phenolic Tank Coating
UseSuitable as a topcoat for oil tanks, chemical tanks and the like

Documents

Mixing RatioBase : curing agent = 83:17 (by volume)
ColourGrey, light grey, red-brown
Flash PointBase 24.0 °C Hardener 10.0 °C
Density1.47 g/ml
Volume Solids77 ± 2% [by volume]
Volatile organic compound content268 g/L
Theoretical spreading rate0.13-0.26 L/m2
ThicknessWFT 130–260 µm, DFT 100–200 µm

(dry film 125 µm)

Temperature10 °C20 °C30 °C40 °C
Drying TimeSurface Dry2.5 h1.5 h30 min15 min
Hard Dry24 h12 h6 h4 h
Recoat intervalAt least24 h16 h14 h8 h
At most*28 days21 days14 days10 days
At most**10 days7 days5 days3 days
Pot life6 h4 h2.5 h1 h

Application conditions

Application methodAirless spray, brush, roller
Weather: temperatureMinimum 10 °C; steel temperature at least 5 °C above the dew point***
Airless spray: viscosity1.3-1.7Pa.S
NozzleGraco619, 621
Paint output pressure14.7-17.7 Mpa
Spray gun speed60–80 cm/s
ThinnerEPOXY THINNER B
Thinning0–10% by volume

Recommended surface preparation

NewbuildingFollow the shipyard standards. Consult your CMP representative for advice.
Repair and maintenanceRemove oil and grease. Remove salts and other contaminants with high-pressure clean water, then dry
Fully. Remove damaged areas by abrasive blasting to at least Sa 2½ (ISO 8507-12007) or with power
power tools to St 3 (ISO 8507-12007).
Rinse with waterConsult your CMP representative for advice.

Surface Preparation

The type and degree depend on the actual condition of the material and the required performance.

Optimum results can be achieved even on lightly corroded or damp steel surfaces.

Use standards consistent with the Worldwide Marine Specifications.

Preceding coatCERABOND 2000, EPICON ZINC RICH PRIMER B-2
Subsequent coatEPICON T-800 HS
PackagingTwo-component

Note: 1. In confined spaces or restricted spaces at low temperature, ventilation is necessary to remove volatilised solvent and promote film formation during application and drying.

2. Stir the base with an electric stirrer to a uniform state, then thoroughly stir all of the curing agent with the base. Finally add an appropriate amount of thinner and mix thoroughly.

3 Excessive solvent may reduce sag resistance. 4 Application at the block stage is not recommended. Application is not permitted where the temperature cannot be controlled.

5 When mixing, mix only the quantity of paint that can be used within the specified pot life.

6 *(1) It is recommended to use shade netting over the coating surface to avoid direct sunlight exposure through manholes or other openings.

If the coating surface has been directly exposed to sunlight, the above “**” indicates the maximum recoat interval

7. ***on steelDew point + minimum 5 °C
on the filmDew point + minimum 3 °C 8 Volume solids, volatile organic content and density are theoretically calculated based on a representative formulation without thinner. The values vary depending on the formulation of different colours.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all CMP models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery