6020A EPICON T-500 PRIMER H Epoxy Tank Coating

Quick Specs

6020A EPICON T-500 PRIMER H Epoxy Tank Coating is an epoxy coating used as a primer. If the product is used as a temporary primer, refer to the precautions. Parameters on this page: volume solids 35 ± 2% (ISO 3233), dry film thickness 50 µm, theoretical spreading rate 0.143 L/m². Comparable models from the same brand: 1050 NZ PRIMER S zinc-free epoxy shop primer, 200 GALVANITE No. 200 PRIMER epoxy galvanised steel primer, 400 GALVANITE No. 400 PRIMER epoxy polyamide resin primer.

Parameter source: CMP original technical data sheet (TDS) for 6020A EPICON T-500 PRIMER H Epoxy Tank Coating; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids35 ± 2% (ISO: 3233)
Dry Film Thickness50 µm
Theoretical Spreading Rate0.143 L/m2
VOC578 g/L (Method 24)
Density / Specific Gravity1.20 g/ml (ISO: 2811)
Number of ComponentsTwo-component
ThinnerEPOXY THINNER B
Mixing RatioBase : curing agent = 73:27 (by volume)
Colour / AppearancePowder brown

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

FAQ

How many components is 6020A EPICON T-500 PRIMER H?
6020A EPICON T-500 PRIMER H is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What is the mixing ratio of 6020A EPICON T-500 PRIMER H?
The mixing ratio of 6020A EPICON T-500 PRIMER H is base : curing agent = 73:27 (by volume).
What dry film thickness is typically applied for 6020A EPICON T-500 PRIMER H?
The typical dry film thickness of 6020A EPICON T-500 PRIMER H is 50 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of 6020A EPICON T-500 PRIMER H?
The theoretical spreading rate of 6020A EPICON T-500 PRIMER H is 0.143 L/m²; the practical quantity is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of 6020A EPICON T-500 PRIMER H?
The volume solids of 6020A EPICON T-500 PRIMER H is 35 ± 2% (ISO 3233).
What is the VOC of 6020A EPICON T-500 PRIMER H?
The VOC of 6020A EPICON T-500 PRIMER H is 578 g/L (Method 24).
What thinner is used for 6020A EPICON T-500 PRIMER H?
Recommended thinner for 6020A EPICON T-500 PRIMER H: EPOXY THINNER B.
What is the flash point of 6020A EPICON T-500 PRIMER H?
The flash point of 6020A EPICON T-500 PRIMER H is base 13 °C, curing agent 15.5 °C. Storage, transport and application are subject to the product safety data sheet.
How long does 6020A EPICON T-500 PRIMER H take to dry?
Drying time of 6020A EPICON T-500 PRIMER H under standard conditions: surface dry; the actual value is affected by temperature, film thickness and ventilation.
Which standards apply to 6020A EPICON T-500 PRIMER H?
As recorded in the technical data on this page: remove the damaged areas by abrasive means to at least the Sa2 1/2 standard (ISO 8507-1 2007), or with power tools to St3 (ISO 8507-1 2007). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can 6020A EPICON T-500 PRIMER H be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

EPICON T-500 PRIMER H is composed mainly of epoxy resin and its curing agent. It has excellent physical properties such as good adhesion and abrasion resistance, and chemical resistance to salt water, petroleum, crude oil, alkali metals and weak acids, and can be used with EPICON T-500.

If the product is used as a temporary primer, refer to the precautions.

Technical data

TypeEpoxy tank coating
UseUsed as a primer for the interior of chemical tankers, and is effective as a temporary primer

Documents

Mixing RatioBase : curing agent = 73:27 (by volume)
ColourPowder brown
Flash PointBase 13 °C Curing agent 15.5 °C
Density1.20 g/ml (ISO: 2811)
Volume Solids35 ± 2% (ISO: 3233)
Volatile organic compound content578 g/L (Method 24)
Theoretical spreading rate0.143 L/m2
ThicknessWet film 143 µm; dry film 50 µm

(at 50 µm dry film)

Temperature10 °C20 °C30 °C40 °C
Drying TimeSurface Dry90 min40 min20 min10 min
Hard Dry16 h8 h4 h2 h
Recoat intervalAt least16 h12 h8 h5 h
At most*28 days21 days15 days
At most**10 days7 days5 days3 days
Pot life24 h16 h12 h8 h

Application conditions

Application methodAirless spray, brush, roller
Weather: temperatureMinimum 10 °C
HumidityMaximum 85% RH; steel temperature at least 5 °C above the dew point
Airless spray: viscosity0.9-1Pa.S
NozzleGraco719
Paint output pressure8.8-11.8 Mpa
Spray gun speed60–160 cm/s
ThinnerEPOXY THINNER B
Thinning0–7% by volume

Recommended surface preparation

NewbuildingFollow the shipyard standards. Consult your CMP representative for advice.
Repair and maintenanceRemove oil and grease. Remove salts and other contaminants with high-pressure clean water, then dry
Fully. Remove damaged areas by abrasive blasting to at least Sa 2½ (ISO 8507-12007) or with power
power tools to St 3 (ISO 8507-12007).
Rinse with waterConsult your CMP representative for advice.

Surface Preparation

The type and degree depend on the actual condition of the material and the required performance.

Optimum results can be achieved even on lightly corroded or damp steel surfaces.

Use standards consistent with the Worldwide Marine Specifications.

Preceding coatCERABOND 2000, NZ PRIMER S, EPICON ZINC RICH PRIMER B-2, etc.
Subsequent coatEPICON T-500
PackagingTwo-component

Note: 1. In confined spaces or restricted spaces at low temperature, ventilation is necessary to remove volatilised solvent and promote film formation during application and drying.

2. Stir the base with an electric stirrer to a uniform state, then thoroughly stir all of the curing agent with the base. Finally add an appropriate amount of thinner and mix thoroughly.

3. Excessive solvent may reduce sag resistance. 4. Mix only the amount of paint that can be used within the specified pot life.

5. * Note: 6. If used as a temporary primer, refer to the following

Application quantity0.076L/m2
Viscosity16 s (Ford Cup #4). Film thickness: wet film 76 micron, dry film 25 micron
(at 25 µm dry film)10°C20°C30°C40°C
Drying TimeSurface Dry15 min10 min6 min3 min
Hard Dry3 h2 h1.5 h30 min
Recoat intervalAt least16 h12 h8 h5 h
At most*28 days21 days15 days
At most**10 days7 days5 days3 days
Pot life24 h16 h12 h8 h

Thinning: for airless spray: 0-10% by volume. 7. Density, volume solids and volatile organic compound content are theoretical values calculated without thinner.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.