Ceilcote 282 Flakeline Anti-corrosion Lining System belongs to Glass Flake. Typical applications of Ceilcote 282 Flakeline include GGH equipment (hot side and cold side), absorber outlet ducts, steel chimneys/flues, and unscrubbed/unpurified gas transport ducts. Ceilcote 282 Flakeline is a glass flake-filled anti-corrosion lining system, particularly suitable for flue gas desulfurization environments. Ceilcote 282 Flakeline can be used as part of the following system: the lining system primer uses Ceilcote 380 or 370HT primer. Parameters on this page: Volume Solids 100% reactive, Dry Film Thickness (DFT) 375–625 µm (15–25 mil), Theoretical Spreading Rate 1.89 m²/L.
Parameter source: AKZONOBEL original technical data sheet (TDS) “Ceilcote 282 Flakeline Anti-corrosion Lining System”; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% active |
|---|---|
| Dry Film Thickness | 375–625 µm (15–25 mil) |
| Theoretical Spreading Rate | 1.89 m²/L |
| VOC | 1.80 lb/gal (216 g/L) US EPA Method 24 11… |
| Density / Specific Gravity | 1.27 kg/L (10.6 lb/gal) |
| Number of Components | Two-component |
| Thinner | Do not thin |
| Mixing Ratio | 1 L Part A : 20 ml Part B (1 gal Part… |
| Gloss | Not applicable |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Ceilcote 282 Flakeline is a glass flake-filled anti-corrosion lining system, particularly suitable for flue gas desulfurization environments.
Typical applications of Ceilcote 282 Flakeline include GGH equipment (hot side and cold side), absorber outlet ducts, steel chimneys/flues, and unscrubbed/unpurified gas transport ducts.
It is also suitable for continuous immersion service in steel seawater absorber towers and as a thin-film coating beneath inorganic linings, glass linings, brick and tile.
CEILCOTE Colour off-white, grey 282 FLAKELINE
| Gloss | Not applicable |
|---|---|
| Volume Solids | 100% active |
| Typical thickness | DFT 375–625 µm (15–25 mil) corresponds to WFT 441–735 µm (17.6–29.4 mil) per coat |
| Practical Spreading Rate | At a dry film thickness of 450 µm and 85% volume solids, the theoretical spreading rate is 1.89 m²/L. At 18 mil dry film thickness and 85% volume solids, the theoretical spreading rate is 76 ft²/US gal. (For more details, see the 'Product Characteristics' section.) |
| Application Methods | Suitable for airless spray, roller, brush. Drying time; self-recoat interval |
| Temperature | Surface Dry | Hard Dry | Minimum | Maximum |
| 10°C (50°F) | 5.5 h | 24 h | 12 h¹ | 28 days |
| 15°C (59°F) | 4 h | 16 h | 8 h¹ | 28 days |
| 25°C (77°F) | 2 h | 5 h | 4 h¹ | 28 days |
| 35°C (95°F) | 90 min | 3 h | 3 h¹ | 28 days |
¹ When the surface temperature exceeds 35 °C (95 °F) or the surface is exposed to sunlight, recoat as soon as the coating is hard enough to walk on, to avoid intercoat adhesion problems.
| Flash point (typical) | Component A 34 °C (93 °F); Component B 77 °C (171 °F); mixed 32 °C (90 °F) |
|---|---|
| Product weight | 1.27 kg/L (10.6 lb/gal) |
| Volatile Organic Compounds | 1.80 lb/gal (216 g/L) US EPA Method 24 114 g/kg EC Solvent Emissions Directive content (Council Directive 2010/75/EU) 0.76 lb/gal (92 g/L) ASTM D2369 Coating hazard GB 30981.2-S-Pb≤1000-NC Complies with GB 30981.2-2025. For more detailed information, see the "Product Characteristics" section. |
All surfaces to be coated must be clean, dry and free of contamination. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Remove any oil and grease by solvent cleaning in accordance with SSPC-SP1.
For steel substrates in immersed, damp or high-temperature service, the product shall be applied over a surface blast-cleaned to Sa3 (ISO 8501-1:2007), SSPC SP5 or NACE No. 1 and coated with a suitable primer. For dry or fume environments, blast cleaning to Sa2½ (ISO 8501-1:2007), SSPC SP10 or NACE No. 2 is appropriate. The surface profile shall be at least 75 µm (3 mil).
Concrete substrate: Ceilcote 282 Flakeline is also suitable for cementitious surfaces under certain conditions; for details, refer to the product application guide.
| Mixing | Ceilcote 282 Flakeline must be mixed and applied in accordance with the detailed application instructions for the subsequent system. |
|---|
The coating is supplied as a two-container unit. Always mix the complete unit in the supplied ratio. Once mixed, the unit must be used within the specified pot life.
(1) Stir the base (Component A) with a power mixer.
(2) Combine all of the curing agent (Component B) with the base (Component A) and stir thoroughly with a power mixer.
Do not mix more paint than can be used within the recommended pot life.
| Mixing ratio | 1 L Part A : 20 ml Part B (1 gal Part A : 2½ fl oz Part B) |
|---|
| Pot life | 10°C (50°F) | 15°C (59°F) | 25°C (77°F) | 35°C (95°F) |
| 60 min | 50 min | 20 min |
| Suitable for airless spray | Recommended nozzle tip size 0.69–0.94 mm (27–37 mil); total fluid pressure at the nozzle not less than 155 kg/cm² (2200 psi) |
|---|
| Brush | For small-area repair only | Several coats may be required to achieve the specified film thickness. |
| Roller application | For small-area repair only | Several coats may be required to achieve the specified film thickness. |
| Thinner | Do not thin |
| Cleaner | Ceilcote T-410 Solvent (or International GTA203) |
|---|---|
| Interruption of work | Do not leave material in lines, guns or spray equipment. Flush all equipment thoroughly with... Ceilcote T410 / International GTA203. Use immediately after mixing; if the pot life is exceeded, discard and remix. |
Once mixed, apply until all the mixed paint is used.
| Cleaning | Clean all equipment with T-410 solvent immediately after use. Periodic flushing of spray equipment during application is also recommended. The frequency of cleaning depends on the quantity sprayed, temperature and time, including all interruptions. |
|---|
Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.
Before using the relevant Ceilcote system, read the detailed Application Guide.
Before work begins, International Paint provides a precise system for dry film thickness and number of coats.
Although Ceilcote 282 Flakeline is 100% reactive, actual volume solids may be lower depending on application conditions; International Protective Coatings recommends an estimated spreading rate value of 85%.
Higher temperatures reduce shelf life. The product, with the curing agent not added and properly sealed, has a shelf life of 3 months at 25 °C (77 °F). Do not store in sunlight. Refrigeration is recommended to keep the material temperature as low as possible, thereby extending the shelf life and the pot life during airless spray. Note that the material temperature rises during mixing. The recommended storage temperature range is 8–19 °C (46–66 °F).
The surface temperature must be at least 3 °C (5 °F) above the dew point. Ensure adequate ventilation during application and curing. Dehumidification, air conditioning and/or heating equipment may be necessary to control the environment.
At all stages of application, the surface, air and paint temperatures must be between 10 °C (50 °F) and 43 °C (110 °F).
When applying outdoors or in sunlight, “bubbling” may occur as the surface temperature rises due to sunlight or ambient temperature. This can cause bubbles or pinholes in the applied flooring, lining or coating. When this occurs, shade the surface from sunlight, and/or apply in the cooler evening or at night, so that air does not escape from the concrete during initial cure. For more detailed advice, consult the International Paint Protective Coatings division.
If the recoat interval is exceeded, wipe with styrene to confirm whether recoating is possible. If the surface feels “slightly tacky”, adhesion is acceptable. If it is not softened by styrene, sweep blast or mechanically abrade the surface to obtain a matt, rough surface. Primed surfaces must be dry and free of foreign matter before lining, coating or flooring.
Subject to correct application procedures, Ceilcote 282 Flakeline may be returned to service after the following intervals: 10 °C (50 °F): 48 h; 20 °C (70 °F): 24 h; 35 °C (90 °F): 16 h. Ceilcote 282 Flakeline is not intended as a decorative topcoat; colour stability is difficult to achieve.
The maximum continuous dry-service temperature resistance of Ceilcote 282 Flakeline is 204 °C (400 °F).
Ceilcote 282 Flakeline may be used as part of the following systems: Lining system — prime with Ceilcote 380 or 370HT primer. Apply additional primer and immediately lay the reinforcement mat, avoiding wrinkles and pinholes. Apply additional material where required until the reinforcement mat becomes translucent. Complete with one or more coats of Ceilcote 282 Flakeline.
Repair system — prime with Ceilcote 380 or 370HT primer, then apply one coat of Ceilcote 6650 with reinforcement mat. Complete with one or more coats of Ceilcote 282 Flakeline.
Ceilline system — prime with Ceilcote 680 or 680M primer, then apply one coat of Ceilcote Ceilline elastic base coat with reinforcement mat. Complete with one or more coats of Ceilcote 282 Flakeline.
Further information may be found in the individual product data sheets.
Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.
Although the low-molecular-weight reactive additive becomes part of the film when cured under normal ambient conditions, analysis by EPA Method 24 shows that it also affects the VOC value.
Ceilcote 282 Flakeline should be applied to suitably prepared substrates. It is, however, suitable for use over the following primers:
| Ceilcote 370HT Primer | Ceilcote 380 Primer. Ceilcote 282 Flakeline may also form part of other systems, for example |
|---|---|
| Ceilcote 282 Ceilline | Ceilcote 282 Lining |
| Ceilcote 282MR | Ceilcote 282AR Flakeline. Ceilcote 282 Flakeline is normally self-recoatable. |
| For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.com | The following documents available on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rates • Ceilcote 282 Flakeline application instructions. These sections are also available as separate publications on request |
|---|
This product is intended for professional applicators in industrial use only.
All work, including the application and use of this product, must comply with the relevant national standards, laws and regulations on safety, health and environmental protection.
During application and the subsequent drying period, provide adequate ventilation to keep solvent concentrations within safe limits and prevent fire and explosion (for general drying times, see the product data sheet). Forced ventilation is required in confined spaces. During application and drying, personal ventilation and/or respiratory protection (e.g. air-fed hood or suitable filter mask) must also be provided. Take the necessary measures to prevent skin and eye contact with the coating (e.g. protective clothing, gloves, goggles, mask, barrier cream).
Before use, read and follow the Health and Safety section of the Material Safety Data Sheet and the application procedure for the product (for two-component coatings, those of the base and curing agent).
If welding or flame cutting is performed on metal substrate coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation.
The specific safety measures depend on the application method and working environment. If these warnings or instructions are not fully understood or cannot be strictly observed, do not use the product and consult the International Paint Protective Coatings division.
| Packaging Specifications | Component A | Component B | ||
| Volume | Packaging | Volume | Packaging | |
| 15 L | 14.71 L | 20 L | 0.29 L | 0.7 L |
| 4 US gal | 5 US gal | 10 fl oz | 1 US pint | |
For other packaging sizes, contact AkzoNobel.
| Packaging Specifications | Component A | Component B |
| 15 L | 20.44 kg | 0.39 kg |
| 4 US gal | 46.7 lb | 1.0 lb |
| Shelf life | Store for 6 months at 20 °C (68 °F). Inspection is required thereafter. Store in a dry, cool environment away from heat and ignition sources. During storage and transport, the temperature of the Ceilcote 282 Flakeline initiator must not exceed 30 °C (90 °F). Refrigeration is recommended. Part A and Part B should be stored separately. |
|---|
© 2026/5/26 AkzoNobel. All rights reserved.
All registered trademarks mentioned in this publication are licensed to or owned by AkzoNobel.
www.international-pc.com
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.