← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard Holding Primer Phenolic Epoxy Temporary Protection Primer

Quick Specs

Tankguard Holding Primer Phenolic Epoxy Temporary Protective Primer is an epoxy coating used as a primer. Industrial protective coatings: specially a lining coating, used with other coatings for offshore, onshore and underground tanks and pipes such as chemical storage, wastewater, grey water, industrial water pipes, concrete bunds, fire water lines and drilling mud tanks. Suitable for suitably prepared carbon steel, galvanised steel, stainless steel and concrete substrates. Parameters on this page: volume solids 43 ± 2%, dry film thickness 20–60 µm, theoretical spreading rate 21.5–7.1 m²/L.

Source: JOTUN original technical data sheet (TDS) "Tankguard Holding Primer Phenolic Epoxy Temporary Protective Primer"; spreading rate and other values are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids43 ± 2%
Dry Film Thickness20–60 µm
Theoretical Spreading Rate21.5–7.1 m²/L
VOC526 g/L (EU)
Density / Specific Gravity1.3 kg/L
Number of ComponentsTwo-component
Flash Point28 °C
ThinnerJOTUN Thinner No. 17 / JOTUN Thinner No. 23
Mixing Ratio7 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy, Phenolic

FAQ

How many components does Tankguard Holding Primer have?
Tankguard Holding Primer is a two-component product. Mix according to the mixing ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of Tankguard Holding Primer?
The mixing ratio of Tankguard Holding Primer is 7 parts : 1 part (by volume).
What dry film thickness is normally applied for Tankguard Holding Primer?
Tankguard Holding Primer is normally applied at 20–60 µm dry film thickness; the exact value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Tankguard Holding Primer?
The theoretical spreading rate of Tankguard Holding Primer is 21.5–7.1 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Tankguard Holding Primer?
The volume solids of Tankguard Holding Primer is 43 ± 2%.
What is the VOC of Tankguard Holding Primer?
The VOC of Tankguard Holding Primer is 526 g/L (EU).
Which thinner is used for Tankguard Holding Primer?
The recommended thinner for Tankguard Holding Primer: JOTUN Thinner No. 17 / JOTUN Thinner No. 23.
What is the flash point of Tankguard Holding Primer?
The flash point of Tankguard Holding Primer is 28 °C. Handle, store and apply in accordance with the product safety data sheet.
How long does Tankguard Holding Primer take to dry?
Drying time of Tankguard Holding Primer under standard conditions: touch dry 15 h; in practice affected by temperature, film thickness and ventilation.
Which standards apply to Tankguard Holding Primer?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard Holding Primer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard Holding Primer

Product description

A two-component polyamine-cured phenolic epoxy coating. Used as a maintenance primer or primer within the complete tank coating system. Excellent chemical resistance. Can be used as a primer in atmospheric and immersed environments. Suitable for suitably prepared carbon steel, galvanised steel, stainless steel and concrete substrates.

Compatible with the following coatings:

Tankguard Plus Phenolic Epoxy High-temperature Tank Coating (0J7)

Tankguard Storage Phenolic Epoxy Tank Coating (0LD)

Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating (6R6)

Tankguard SF Solvent-free Phenolic Epoxy Tank Coating (0GE)

Tankguard HB Classic Pure Epoxy Tank/Storage Coating (0XU)

Tankguard NCV Phenolic Epoxy Antistatic Coating (0H2)

Chemtech GM

Chemflake Classic

Typical Use

Industrial protective coatings:

Specially a lining coating, used with other coatings for offshore, onshore and underground tanks and pipes such as chemical storage, wastewater, grey water, industrial water pipes, concrete bunds, fire water lines and drilling mud tanks. This product is compatible with many specific coatings.

Others

Approvals and Certificates

Approved per UK Defence Standard 80-97 Edition 5, Annex B, as resistant to F-34 FSII aviation turbine engine fuel. Other certificates and approvals available on request.

Colour

Light yellow

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323343± 2 %
Gloss (GU 60°)ISO 2813Matt (0–35)
Flash PointISO 3679 Method 128 °C
DensityTheoretical Value1.3 kg/L
RegionRegulationsTest / StandardVOC Value
EUEuropean Paint Directive 2004/42/CECalculation526 g/L

China GB 30981-2020 Limit of Harmful Substances. GB/T 23985-2009 8.3 494 g/L of industrial protective coatings. The data listed are based on factory batch production products and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness20–60 µm
Wet Film Thickness50–140 µm
Theoretical Spreading Rate21.5–7.1 m²/L

Surface Preparation

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Coated surfaceA clean, dry and sound compatible primer.
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.
ConcreteDry abrasive blast clean to SSPC-SP 13 / NACE No. 6.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.
Roller applicationRoller application may be used only in areas such as drain holes, rat holes and small pipes.

Mixing Ratio (by Volume)

Tankguard Holding Primer Comp A — Phenolic Epoxy Holding Primer, Component A7 parts
Tankguard Holding Primer Comp B — Phenolic Epoxy Holding Primer, Component B1 part

Thinner / Cleaning Solvent

ThinnerJOTUN Thinner No. 17 / JOTUN Thinner No. 23

Airless Spray Guidance

Nozzle tip size (inch/1000):17-21
Nozzle pressure (minimum):150 bar/2100 psi

Drying and Curing Time

Substrate Temperature10 °C15 °C23 °C40 °C
Touch Dry15 h12 h4 h2 h
Walk-on Dry24 h20 h10 h4 h
Minimum recoat interval24 h20 h10 h4 h
Dry/cured to service14 days7 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Induction Time20 min
Pot Life4 h

Heat Resistance

Temperature

Drying, atmosphericContinuous 200 °CPeak -
Immersed, sea water70 °C95 °C
Immersed, crude oil80 °C90 °C

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Subsequent CoatEpoxy, phenolic epoxy, unsaturated vinyl ester. Tankguard Holding Primer can be used for short-term protection and is fully compatible with tank coating systems.

Typical Packaging Sizes

VolumeContainer Size
(L)
Tankguard Holding Primer Comp A — Phenolic Epoxy Holding Primer, Component A17.520
Tankguard Holding Primer Comp B — Phenolic Epoxy Holding Primer, Component B2.53

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Tankguard Holding Primer Comp A — Phenolic Epoxy Holding Primer, Component A24 months
Tankguard Holding Primer Comp B — Phenolic Epoxy Holding Primer, Component B24 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, epoxy coating, phenolic coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery