← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard HB Classic Pure Epoxy Tank Coating

Quick Specs

Tankguard HB Classic Pure Epoxy Tank Coating belongs to Epoxy. Industrial protective coatings segment: recommended as an internal lining coating for offshore, onshore and underground tanks and pipelines. Can be used as primer, intermediate coat or topcoat under atmospheric and immersed conditions. Parameters on this page: volume solids 65 ± 2%, DFT 80–160 µm, theoretical spreading rate 8.1–4.1 m²/L. Comparable models from the same brand: Balloxy HB Light Epoxy Ballast Water Tank Coating, Jota Armour Heavy-duty Abrasion-resistant Epoxy Anti-slip Coating, Jotacote HF002 General-purpose Abrasion-resistant Epoxy HF.

Parameter source: JOTUN original technical data sheet (TDS) Tankguard HB Classic Pure Epoxy Tank Coating; values such as spreading rate are converted from TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids65 ± 2%
Dry Film Thickness80–160 µm
Theoretical Spreading Rate8.1–4.1 m²/L
VOC280 g/L (China)
Density / Specific Gravity1.5 kg/L
Number of ComponentsTwo-component
Flash Point23.5 °C
ThinnerJOTUN Thinner No. 17 / JOTUN Thinner No. 23
Mixing Ratio4 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Epoxy

FAQ

How many components does Tankguard HB Classic have?
Tankguard HB Classic is a two-component product; mix in the ratio given in the "Coating Data" table on this page before use.
What is the mixing ratio of Tankguard HB Classic?
The mixing ratio of Tankguard HB Classic is 4 parts : 1 part (by volume).
What DFT is normally applied for Tankguard HB Classic?
The normal DFT of Tankguard HB Classic is 80–160 µm; the specific value depends on the coating system and design requirements.
What is the theoretical spreading rate of Tankguard HB Classic?
The theoretical spreading rate of Tankguard HB Classic is 8.1–4.1 m²/L; actual consumption is adjusted for substrate roughness, application losses and colour hiding power.
What is the volume solids of Tankguard HB Classic?
The volume solids of Tankguard HB Classic is 65 ± 2%.
What is the VOC of Tankguard HB Classic?
The VOC of Tankguard HB Classic is 280 g/L (China).
Which thinner is used for Tankguard HB Classic?
Recommended thinner for Tankguard HB Classic: JOTUN Thinner No. 17 / JOTUN Thinner No. 23.
What is the flash point of Tankguard HB Classic?
The flash point of Tankguard HB Classic is 23.5 °C; storage, transport and application shall follow the product safety data sheet.
How long does Tankguard HB Classic take to dry?
Drying time of Tankguard HB Classic under standard conditions: touch dry 24 h; actual values are affected by temperature, film thickness and ventilation.
Which standards apply to Tankguard HB Classic?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard HB Classic be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard HB Classic

Product description

This is a two-component polyamine-cured epoxy coating. It has good chemical resistance. It can be used as primer, intermediate coat or topcoat under atmospheric and immersed conditions. Suitable for properly prepared carbon steel, galvanized steel, stainless steel and concrete substrates.

Typical Use

Marine coatings:

Designed as an internal tank coating for chemical tanks. The coating has good resistance to many products. Refer to the marine coatings resistance table at www.jotunprl.com. Can be used as coating for grey water, drill mud, brine and crude oil tanks.

Industrial protective coatings:

Recommended as an internal lining coating for offshore, onshore and underground storage tanks and pipelines. Refer to the industrial protective coatings resistance table.

Others

Approvals and Certificates

Complies with Section 175.300 of Title 21 of the US Federal Food and Drug Administration regulations; documented as suitable for exposure to dry and liquid food.

Certified according to IMO Res.288(87) and suitable for the PSPC standard for crude oil tanks. Other certificates and approvals are available on request.

Colour

Pink, grey, yellow

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323365± 2 %
Gloss (GU 60°)ISO 2813Matt (0–35)
Flash PointISO 3679 Method 123.5 °C
DensityTheoretical Value1.5 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation334 g/L
Hong KongAir Pollution Control (VOC) RegulationCalculation334 g/L
EUEuropean Paint Directive 2004/42/CECalculation334 g/L
ChinaGB 30981-2020 Limit of harmful substances of industrial protective coatingsGB/T 23985-2009 8.3280 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness80–160 µm
Wet Film Thickness125–245 µm
Theoretical Spreading Rate8.1–4.1 m²/L

The maximum recommended film thickness is generally exceeded in overlap areas and hard-to-spray areas.

Surface Preparation

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Coated surfaceA clean, dry and sound compatible primer.
ConcreteDry abrasive blast clean to SSPC-SP 13 / NACE No. 6.
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.

Application

Application Methods

This product may be applied by the following methods

SprayApply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.
Roller:Roller application may be used only in areas such as drain holes, rat holes and small pipes.

Mixing Ratio (by Volume)

Tankguard HB Classic Comp A Pure Epoxy Tank Coating, Component A4 parts
Tankguard HB Classic Comp B Pure Epoxy Tank Coating, Component B1 part

Thinner / Cleaning Solvent

ThinnerJOTUN Thinner No. 17 / JOTUN Thinner No. 23

Airless Spray Guidance

Nozzle tip size (inch/1000):17-23
Nozzle pressure (minimum):150 bar/2100 psi

Drying and Curing Time

Substrate Temperature0 °C5 °C10 °C15 °C23 °C30 °C40 °C
Touch Dry24 h14 h8 h6 h3 h2 h1 h
Walk-on Dry30 h20 h10 h8 h4 h3 h2 h
Minimum recoat interval34 h24 h12 h10 h4 h3 h2 h
Dry/cured to immersion18 days13 days6 days5 days4 days3 days2 days
Dry/cured to service38 days26 days13 days11 days7 days5 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to immersion: the minimum time before the coating can be permanently immersed in sea water.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature0 °C10 °C23 °C30 °C40 °C
Induction Time15 min10 min5 min
Pot Life5 h3 h2 h1.5 h45 min
Induction time and pot life are reduced at higher temperatures

Heat Resistance

Temperature

Drying, atmosphericContinuous 120 °CPeak 140 °C
Immersed, sea water60 °C
Immersed, crude oil90 °C

For more resistance information, refer to the marine coatings resistance list and/or the protective coatings resistance list on the JOTUN website, or contact the local JOTUN office.

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Epoxy
Subsequent coat:Epoxy

Typical Packaging Sizes

VolumeContainer Size
(L)
Tankguard HB Classic Comp A Pure Epoxy Tank Coating, Component A1620
Tankguard HB Classic Comp B Pure Epoxy Tank Coating, Component B45

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Tankguard HB Classic Comp A Pure Epoxy Tank Coating, Component A24 months
Tankguard HB Classic Comp B Pure Epoxy Tank Coating, Component B24 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery