Jotatemp 250 Glass Flake Reinforced Phenolic Epoxy Heat-resistant Coating belongs to heat-resistant coatings, epoxy coating systems. Industrial protective coatings field: provides corrosion protection for surfaces operating at high temperatures. Designed as a heat-resistant coating, it can withstand low temperatures down to -196 °C and high temperatures up to 250 °C on carbon steel substrates. Parameters on this page: volume solids 70 ± 2%, dry film thickness 140–200 µm, theoretical spreading rate 5–3.5 m²/L. Comparable models from the same brand and category: Jotatemp 210 Phenolic Epoxy Heat-resistant Coating, Tankguard Special Plus Two-component Polyamine-cured Phenolic Epoxy Coating, Tankguard Holding Primer Phenolic Epoxy Temporary Protective Primer.
Parameter source: JOTUN original technical data sheet (TDS) Jotatemp 250 Glass Flake Reinforced Phenolic Epoxy Heat-resistant Coating; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 70 ± 2% |
|---|---|
| Dry Film Thickness | 140–200 µm |
| Theoretical Spreading Rate | 5–3.5 m²/L |
| VOC | 276 g/L (US) |
| Density / Specific Gravity | 1.5 kg/L |
| Number of Components | Two-component |
| Flash Point | 28 °C |
| Mixing Ratio | 5 parts : 1 part (by volume) |
| Gloss | Matt (0–35) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Jotatemp 250
This is a two-component, glass flake reinforced epoxy coating. Designed as a heat-resistant coating, it can withstand low temperatures down to -196 °C and high temperatures up to 250 °C on carbon steel substrates. Suitable for insulated and uninsulated surfaces. Suitable for properly prepared carbon steel, stainless steel, alloy steel (P91), galvanized steel and aluminium. Can be applied to hot substrates at temperatures up to 150 °C.
Refer to the application instructions for more detailed information. The product can be used as a primer, intermediate coat or topcoat. It provides adequate anticorrosive protection at ambient temperature during construction and shutdown periods. This product has passed tests applicable to anticorrosive coatings under insulation.
Industrial protective coatings:
Provides corrosion protection for surfaces operating at high temperatures. Particularly suitable for under insulation. Suitable for insulated and uninsulated surfaces.
Others
Pre-qualified in selected coating systems according to Norsok M-501. Tested in accordance with AMPP TM21442. Tested in accordance with AMPP TM21442. Tested in accordance with ISO 19277, including low-temperature and vertical pipe tests.
Tested in accordance with a cyclic ageing test similar to that described in ISO 12944-9 CX.
Tested in accordance with ISO 12944-6 C5 High.
Tested in accordance with ASTM D6944.
Tested in accordance with ISO 3248 on stainless steel (SS304) at 204 °C for 1000 h.
Tested in accordance with ISO 3248 on alloy steel (P91) at 204 °C for 1000 h.
Internal testing
Internal testing in accordance with ISO 3248 on carbon steel at 250 °C for 1000 h.
Internal testing of stainless steel (SS304) was conducted at 230 °C for 1000 h in accordance with ISO 3248.
Internal testing of alloy steel (P91) was conducted at 230 °C for 1000 h in accordance with ISO 3248.
Other certificates and approvals are available on request.
White, red, light grey, aluminium. Aluminium-coloured coatings should not be overcoated.
Other colours available on request
| Property | Test / Standard | Description |
| Volume Solids | ISO 3233 | 70± 2 % |
| Gloss (GU 60°) | ISO 2813 | Matt (0–35) |
| Flash Point | ISO 3679 Method 1 | 28 °C |
| Density | Theoretical Value | 1.5 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | US EPA Method 24 | 276 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | 276 g/L |
| EU | European Paint Directive 2004/42/CE | Calculation | 311 g/L |
| China | GB 30981-2020 Limit of harmful substances of industrial protective coatings | GB/T 23985-2009 8.3 | 238 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
Typical recommended specification range
| Dry Film Thickness | 140–200 µm |
| Wet Film Thickness | 200–300 µm |
| Theoretical Spreading Rate | 5–3.5 m²/L |
Surface Preparation
| Substrate | Minimum | Recommended |
| Carbon Steel | St 2 (ISO 8501-1) if the temperature does not exceed 230 °C | Sa 2½ (ISO 8501-1) |
| Stainless steel | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” |
to produce scratch marks on the surface.
| Aluminium | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” |
| Galvanised steel | The surface should be clean, dry and have a suitable profile | Sweep blast with a non-metallic abrasive to produce a clean, |
| ° | a rough and uniform surface. | |
| Shop-primed Steel | Dry, clean, certified inorganic zinc shop primer | Sa 2½ (ISO 8501-1) |
| Coated surface | A clean, dry and sound compatible primer. | |
This product may be applied by the following methods
| Spray: | Apply by airless spray. |
| Brush: | Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. |
| Jotatemp 250 Comp A — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component A | 5 parts |
| Jotatemp 250 Comp B — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component B | 1 part |
| Thinner: | JOTUN Thinner No. 17 | /JOTUN Thinner No. 23 |
| Maximum thinning: | 10 % |
Normally no thinning is required. For application under extreme conditions, consult the local JOTUN representative. Do not thin beyond the requirements of local environmental regulations.
| Note | Where the Korean VOC regulation (Clean Air Conservation Act) and its corresponding thinning limits differ from the recommended thinning volume, the former prevails. |
|---|
| Nozzle tip size (inch/1000): | 19-21 |
| Nozzle pressure (minimum): | 150 bar/2100 psi |
| Substrate Temperature | 10 °C | 15 °C | 23 °C | 40 °C | 100 °C |
| Touch Dry | 12 h | 6 h | 2.5 h | 1.5 h | 20 min |
| Walk-on Dry | 24 h | 13 h | 7 h | 2.5 h | 20 min |
| Minimum recoat interval | 13 h | 6 h | 2.5 h | 1.5 h | 0 min |
| Dry/cured to service | 25 days | 21 days | 18 days | 3 days | 1 day |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Rapid evaporation above 100 °C may cause flash drying. Determination of drying and curing times is based on temperature and relative humidity, with relative humidity below 85% and dry film thickness within the average dry film thickness range.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 23 °C |
| Induction Time | 20 min |
| Pot Life | 2 h |
Induction time and pot life are shortened at higher temperatures.
Carbon steel:
| Continuous | 250°C |
|---|---|
| Peak | 300°C |
Stainless steel:
| Continuous | 230°C |
|---|
Alloy steel:
| Continuous | 230°C |
|---|
Galvanized steel:
| Continuous | 204°C |
|---|
Aluminium
| Continuous | 204°C |
|---|
The continuous service temperature limit is based on the heat resistance of the substrate.
Discolouration may occur in high-temperature environments, which may affect the appearance. In addition, epoxy-based products used as topcoat may chalk when exposed to sunlight and weathering. This is a phenomenon that can be expected on the outermost surface.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Inorganic zinc silicate, itself |
| Subsequent coat: | Glass flake reinforced epoxy, silicone acrylic * * Maximum heat resistance temperature is 230 °C (446 °F) |
| Volume | Container Size | |
| (L) | ||
| Jotatemp 250 Comp A — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component A | 4.17/15 | 5/20 |
| Jotatemp 250 Comp B — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component B | 0.83/3 | 1/3 |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Jotatemp 250 Comp A — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component A | 24 months |
| Jotatemp 250 Comp B — Glass Flake Reinforced Phenolic Epoxy Heat-Resistant Coating, Component B | 24 months |
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.