China-based coatings exporter — industrial & marine protective coatings from China's production bases

Intergard 5620 Epoxy Universal Primer

Quick Specs

Intergard 5620 Epoxy Universal Primer is an epoxy coating used as a primer. Used as a general-purpose anticorrosive primer in ballast tanks, external hulls, cofferdams, void spaces, decks, cargo holds and crude oil tanks. A light-coloured, epoxy universal primer that can be applied in winter at temperatures as low as -5 °C. Parameters on this page: volume solids 68% ± 2%, dry film thickness 160 µm, theoretical spreading rate 4.25 m²/L. Comparable models from the same brand: Interbond 201 - Temperate epoxy primer, Interbond 808 epoxy anticorrosive paint, Intergard 5101 epoxy universal primer.

Parameter source: INTERNATIONAL original technical data sheet (TDS) for Intergard 5620 Epoxy Universal Primer; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids68% ± 2%
Dry Film Thickness160 µm
Theoretical Spreading Rate4.25 m²/L
VOC320 g/L (as supplied) (EPA Method 24); 275 g/L…
Density / Specific Gravity—
Number of ComponentsTwo-component
Mixing RatioComponent A : Component B = 3:1 (by volume)
Colour / AppearanceKUA622 grey, KUA626 red
GlossN/A

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

FAQ

What is the mixing ratio of Intergard 5620?
The mixing ratio of Intergard 5620 is Component A : Component B = 3:1 (by volume).
What dry film thickness is typically applied for Intergard 5620?
The typical dry film thickness of Intergard 5620 is 160 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Intergard 5620?
The theoretical spreading rate of Intergard 5620 is 4.25 m²/L; the practical quantity is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Intergard 5620?
The volume solids of Intergard 5620 is 68% ± 2%.
What is the VOC of Intergard 5620?
The VOC of Intergard 5620 is 320 g/L (as supplied) (EPA Method 24), 275 g/L…
What is the gloss of Intergard 5620?
The gloss of Intergard 5620 is not applicable.
What is the flash point of Intergard 5620?
The flash point of Intergard 5620 is Component A 25 °C; Component B 26 °C; mixed 28 °C. Storage, transport and application are subject to the product safety data sheet.
How is Intergard 5620 applied?
Application method for Intergard 5620: airless spray, brush and roller; surface preparation and the coating system are as described on this page.
Which standards apply to Intergard 5620?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intergard 5620 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A light-coloured, epoxy universal primer that can be applied in winter at temperatures as low as -5 °C.

Intended use

Used as a general-purpose anticorrosive primer in ballast tanks, hull exteriors, cofferdams, void spaces, decks, cargo holds and crude oil tanks.

Suitable for use with impressed current cathodic protection.

For newbuilding or maintenance and repair.

Product information

ColourKUA622 grey, KUA626 red
Topcoat/glossN/A
Component B (curing agent)KUA623
Volume Solids68% ±2% (ISO 3233:1998)
Mixing ratioComponent A : Component B = 3:1 (by volume)
Standard film thickness160 µm DFT (235 µm WFT)
Theoretical Spreading RateTheoretical spreading rate at 160 µm DFT is 4.25 m²/L, allowing for a suitable loss factor
Application MethodsAirless spray, brush, roller
Flash PointComponent A 25 °C; Component B 26 °C; mixed 28 °C
Induction TimeNot required
Drying data-5°C5°C25°C35°C
Touch dry [ISO 9117/3:2010]6 h4 h60 min50 min
Hard dry [ISO 9117-1:2009]30 h16 h6 h3 h
Pot life after mixing6 h5 h2 h60 min
Recoat data — see the “Limitations” sectionSubstrate Temperature
When recoating the following products-5 °C minimum-5 °C maximum-5 °C minimum5 °C maximum25 °C minimum25 °C maximum35 °C minimum35 °C maximum
Intergard 26330 h3 months12 h3 months4 h3 months2.5 h2 months
Intergard 26930 h3 months14 h3 months6 h3 months3 h2 months
Intergard 410-16 h3 months6 h3 months3 h2 months
Intergard 562030 h15 days16 h15 days6 h15 days4 h15 days

Immersion areas

Intergard 562030 h 3 months 16 h 3 months 6 h 3 months 3 h 2 months non-immersed areas
Intergard 740- 10 days 12 h 10 days 4 h 10 days 2.5 h 7 days
Interthane 99030 h 5 days 14 h 5 days 6 h 5 days 3 h 3 days

Regulatory data

Volatile Organic Compounds320 g/L (as supplied) (EPA Method 24); 275 g/L China national standard GB 23985. Volatile organic compound values are typical and provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances.

Certificates

When used as part of an approved scheme, the coating holds the following certificates: • Food contact - grain loading (NOHA) • Fire resistance - complies with low flame spread requirements (Exova Warringtonfire) • Fire resistance - Smoke and Toxicity (Exova Warringtonfire) • Fire resistance - complies with the Marine Equipment Directive. For details, consult the local International Paint representative.

System and compatibility

For the paint system best suited to the surface to be protected, consult your local International Paint representative.

Surface Preparation

Applied in accordance with the standard Worldwide Marine Specifications.

Before applying each coat, all surfaces to be coated must be clean, dry and free from any contaminants.

Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.

When used as a temporary primer to protect blast-cleaned surfaces, Intergard 5620 can be applied over Intergard 269. The primer surface must be dry and free from any contamination, and Intergard 5620 must be applied within the specified recoating interval (refer to the Intergard 269 product data sheet).

On newbuildings, remove weld spatter and grind welds and sharp edges smooth where required.

Welds and damaged areas of shop primer must be blast cleaned to Sa 2.5 (ISO 8501-1:2007) or prepared with power tools to Pt3 (JSRA SPSS:1984).

Intact, approved shop primer must be clean, dry and free of soluble salts and any other surface contaminants.

Unapproved shop primer must be fully blast cleaned to Sa 2.5 (ISO 8501-1:2007). In some cases, sweep blasting to a specified International Paint standard (e.g. AS2 or AS3) is acceptable. For specific advice, consult your local International Paint representative.

Major repair: abrasive blast clean to Sa 2.5 (ISO 8501-1:2007).

For maintenance, consult International Paint.

Blasted areas should be primed before oxidation occurs. If oxidation has occurred, the entire oxidised area must be re-blasted to the specified standard.

In-service maintenance: for tank coating projects, consult International Paint for the detailed tank coating procedure to be followed.

For specific advice, consult your local International Paint representative.

Application

Mixing

The coating is supplied in two containers as one unit. Always mix the entire unit in the supplied ratio. Once mixed, use within the specified pot life.

1) Stir the base (Component A) with a power mixer.

2) Mix all of the base (Component A) with the curing agent (Component B) and stir thoroughly with a power mixer.

Thinner

International GTA220. Normally no thinning is required. Under extreme conditions, consult your local representative for application advice. Do not thin beyond the limits of local environmental regulations.

Airless Spray

Recommended nozzle size 0.53–0.66 mm (21–26 thou); total output fluid pressure at the nozzle not less than 176 kg/cm² (2500 psi)

Brush

Brush application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Roller application

Roller application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Cleaner

International GTA415/GTA822

Interruption of work and cleaning

Do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International GTA415/GTA822. Once mixed, a batch of paint shall not be re-sealed; if work is interrupted for a long period, remix the components before resuming.

All equipment shall be cleaned with International GTA415/GTA822 immediately after use. Periodically flushing spray equipment during the working day is good practice. The frequency of cleaning depends on the quantity sprayed, temperature and elapsed time (including delays). Do not exceed the pot life of the mixed paint.

All surplus paint and empty containers must be disposed of in accordance with appropriate local regulations/laws.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.

Limitation

The product does not cure adequately below -5 °C.

Drying times and overcoating intervals may vary with site factors such as tank geometry or ventilation rate.

Intergard 5620 must not be used in schemes containing Intergard 5600.

Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.

Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.

Under certain climatic conditions, especially at low temperature and high humidity, amine blooming may occur on the coating surface during drying. To prevent this, an induction time of 30 minutes between mixing and application is recommended at temperatures below 25 °C.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
20 L15 L20 L5 L

For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
20 L33.3 kg

Storage

Shelf lifeComponent A: 6 months at 25 °C; Component B: 12 months at 25 °C, after which re-inspection is required. Store in a cool, dry place away from heat and ignition sources.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, epoxy coating

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery