China-based coatings exporter — industrial & marine protective coatings from China's production bases

Intergard 5555 epoxy primer

Quick Specs

Intergard 5555 Epoxy Primer belongs to epoxy coatings and is used as a primer. Used as a primer/topcoat for interior areas such as engine rooms and accommodation spaces. A two-component epoxy primer/topcoat with excellent colour retention. Parameters on this page: volume solids 62% ± 2%, dry film thickness 100 µm, theoretical spreading rate 6.2 m²/L. Comparable products from the same brand: Interbond 201 - Temperate Epoxy Primer, Interbond 808 Epoxy Anti-corrosive Paint, Intergard 5101 Epoxy Universal Primer.

Parameter source: International original technical data sheet (TDS) "Intergard 5555 Epoxy Primer"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids62% ± 2%
Dry Film Thickness100 µm
Theoretical Spreading Rate6.2 m²/L
VOC338 g/L (as supplied) (EPA Method 24) 381 g/L (as sup…
Density / Specific Gravity—
Number of ComponentsTwo-component
Mixing RatioComponent A : Component B = 3:1 (by volume)
Colour / AppearanceEOB000-White, EOK724-Storm Grey, EOL274-Red, E…
GlossSemi-gloss

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

FAQ

How many components does Intergard 5555 have?
Intergard 5555 is a two-component product; mix according to the mixing ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of Intergard 5555?
The mixing ratio of Intergard 5555 is Component A:Component B = 3:1 (by volume).
What dry film thickness is typically applied for Intergard 5555?
The conventional dry film thickness of Intergard 5555 is 100 µm; the specific value is determined by the coating scheme and design requirements.
What is the theoretical spreading rate of Intergard 5555?
The theoretical spreading rate of Intergard 5555 is 6.2 m²/L; the actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Intergard 5555?
The volume solids of Intergard 5555 is 62% ± 2%.
What is the VOC of Intergard 5555?
The VOC of Intergard 5555 is 338 g/L (as supplied) (EPA Method 24) 381 g/L (as sup….
What is the gloss of Intergard 5555?
The gloss of Intergard 5555 is semi-gloss.
What is the flash point of Intergard 5555?
The flash point of Intergard 5555 is Component A 25 °C; Component B 27 °C; after mixing 25 °C. Storage, transport and application shall be carried out in accordance with the product safety data sheet.
How is Intergard 5555 applied?
Application method for Intergard 5555: airless spray, brush, conventional spray and roller; surface preparation and the coating system are as described on this page.
Which standards are involved for Intergard 5555?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intergard 5555 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A two-component epoxy primer/topcoat with excellent colour retention. It is also used as a primer on galvanized steel and stainless steel.

Intended use

Used as a primer/topcoat for interior areas such as engine rooms and accommodation spaces.

For new shipbuilding, Intergard 5555 provides better yellowing resistance.

Product information

ColourEOB000-White, EOK724-Storm Grey, EOL274-Red, EOL549-Signal Green, EOY999-Black; and a wide range of colours.
Topcoat/glossSemi-gloss
Component B (curing agent)EOA046
Volume Solids62% ±2% (ISO 3233:1998)
Mixing ratioComponent A : Component B = 3:1 (by volume)
Standard film thickness100 µm dry film thickness (161 µm wet film thickness)
Theoretical Spreading RateAt 100 µm dry film thickness, the theoretical spreading rate is 6.2 m²/L, allowing for an appropriate loss factor
Application MethodsAirless spray, brush, conventional spray, roller
Flash PointComponent A 25 °C; Component B 27 °C; after mixing 25 °C
Induction TimeNot required
Drying data-5°C5°C25°C35°C
Touch dry [ISO 9117/3:2010]7 h6 h4 h2 h
Hard dry [ISO 9117-1:2009]28 h24 h12 h8 h
Pot life after mixing14 h12 h6 h3 h
Recoat data — see the “Limitations” sectionSubstrate Temperature
When recoating the following products-5 °C minimum-5 °C maximum5 °C minimum5 °C maximum25 °C minimum25 °C maximum35 °C minimum35 °C maximum
Intergard 555520 hUnlimited16 hUnlimited8 hUnlimited6 hUnlimited

Regulatory data

Volatile Organic Compounds338 g/L (as supplied) (EPA Method 24)381 g/L (as supplied) (Korea Clean Air Conservation Act)345 g/L Chinese National Standard GB23985VOC values are typical and are provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances.

Coating hazard GB 30981.2-S-Pb≤90-C complies with GB 30981.2-2025

Certificates

When used as part of an approved scheme, this coating has the following certificates:• Fire resistance — in accordance with the provisions of the "Marine Equipment Directive"• Fire resistance — in accordance with low flame spread requirements (Exova Warringtonfire)For details, consult your local representative.

System and compatibility

Intergard 5555 may only be applied over epoxy anti-corrosive primers and may be overcoated with epoxy or alkyd primers and alkyd or polyurethane topcoats. The primer or topcoat used depends on the vessel area and application location. Typical primers or topcoats include:Intergard 400Intergard 7500Interprime 198Interprime 538Interlac 665Interthane 989For the ideal primer system for the application, consult your local representative.

Surface Preparation

Applied in accordance with the standard Worldwide Marine Specifications.

All surfaces to be coated must be clean, dry and free of contaminants.

Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.

On newbuildings, remove weld spatter and grind welds and sharp edges smooth where required.

Weld seams and damaged shop-primed areas shall be prepared at least to St2 (ISO 8501-1:2007) by hand or power tool.

Intact, approved shop primer must be clean, dry and free of soluble salts and any other surface contaminants.

Non-approved shop primer shall be thoroughly cleaned to St3 (ISO 8501-1:2007) by power tool. In some cases, sweep blasting to the specified International Paint standard (e.g. AS2 or AS3) is also acceptable. For specific recommendations, consult your local representative.

For specific advice, consult your local representative.

Application

Mixing

The coating is supplied in two containers as one unit. Always mix the entire unit in the supplied ratio.

(1) Stir the base (Component A) with a power mixer.

(2) Mix all of the curing agent (Component B) with the base (Component A) and stir thoroughly with a power mixer.

Thinner

Use International GTA220 only in special cases. Do not thin beyond the range permitted by local environmental regulations.

Airless Spray

Recommended nozzle size 0.38–0.53 mm (15–21 thou); total output fluid pressure at the nozzle not less than 176 kg/cm² (2500 psi)

Conventional spray

Use suitable dedicated equipment. Thinning may be required.

Brush

Brush application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Roller application

Roller application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Cleaner

Interruption of work and cleaning

Do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International thinner. Once mixed, paint should not be resealed; if work is interrupted for too long, mix a fresh batch before resuming application.

All equipment shall be cleaned with International thinner immediately after use. Periodically flushing spray equipment during the working day is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, relative humidity and elapsed time (including delays). Do not exceed the pot life of the mixed paint.

All surplus paint and empty containers must be disposed of in accordance with appropriate local regulations/laws.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.

Limitation

The product does not cure adequately below -5 °C.

Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.

Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.

In the Recoat Data section, unlimited = 'ext'. See the Marine Painting Guide — Definitions and Abbreviations available on our website.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
15 L11.25 L18 L3.75 L5 L
20 L15 L20 L5 L

For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
15 L22.82 kg
20 L30.45 kg

Storage

Shelf life12 months at 25 °C. Thereafter, re-inspection is required. Store in a cool, dry place away from heat and sources of ignition.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, epoxy coating

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

Factory item number list (1 in total)

The factory item numbers for Intergard 5555 Epoxy Primer are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.

Item No.Colour / colour codePackaging Specifications
EOB000—20 KG

This model has a total of1item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.

China production baseIndustrial & marine coatingsWorldwide delivery