Quick Specs

Hempel High-performance Epoxy High-build 750 is an epoxy paint. Hempel High-performance Epoxy High-build 750 is recommended as a high-build, self-priming intermediate coat for offshore and other demanding environments requiring fast handling and short overcoating times. Hempel High-performance Epoxy High-build 750 is a self-priming high-solids epoxy coating combining high-performance amine and polyamide. Parameters on this page: volume solids 80 ± 2%, dry film thickness 150 µm, theoretical spreading rate 5.3 m²/L. Comparable products of the same brand: Hempel Fibre-reinforced Extra-strong Epoxy Paint 47510, Hempel Multi-purpose Epoxy High-build Paint 500 Winter Type, Hempel Multi-purpose Epoxy High-build Paint 500.

Data source: HEMPEL original Technical Data Sheet (TDS), "Hempel High-performance Epoxy High-build 750"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids80 ± 2%
Dry Film Thickness150 µm
Theoretical Spreading Rate5.3 m²/L
VOC192 g/L (China)
Density / Specific Gravity1.6 kg/L
Number of ComponentsTwo-component
Flash Point26°C
ThinnerHEMPEL's Thinner 08450
Colour / AppearanceMedium Grey 11480

Browse Similar Models by CategoryThis model belongs to: Epoxy

FAQ

What is the typical dry film thickness for Hempel High-performance Epoxy High-build 750?
The typical dry film thickness of Hempel High-performance Epoxy High-build 750 is 150 µm; the exact value depends on the coating system and design requirements.
What is the theoretical spreading rate of Hempel High-performance Epoxy High-build 750?
The theoretical spreading rate of Hempel High-performance Epoxy High-build 750 is 5.3 m²/L; actual consumption depends on substrate roughness, application losses and colour opacity.
What is the volume solids of Hempel High-performance Epoxy High-build 750?
The volume solids of Hempel High-performance Epoxy High-build 750 is 80 ± 2%.
What is the VOC of Hempel High-performance Epoxy High-build 750?
The VOC of Hempel High-performance Epoxy High-build 750 is 192 g/L (China).
What thinner is used with Hempel High-performance Epoxy High-build 750?
Recommended thinner for Hempel High-performance Epoxy High-build 750: Hempel Thinner 08450.
What is the flash point of Hempel High-performance Epoxy High-build 750?
The flash point of Hempel High-performance Epoxy High-build 750 is 26 °C; storage, transport and application shall follow the product Safety Data Sheet.
Which standards apply to Hempel High-performance Epoxy High-build 750?
As recorded in the technical data on this page: service temperature: under dry conditions: maximum service temperature 120°C [248°F]. Certificates / approvals: when used as part of a specified coating system, meets the requirements of ISO 12944; new construction: abrasive blast cleaning to a minimum of Sa 2½ (ISO 8501-1) / SP 10 (SSPC). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Hempel High-performance Epoxy High-build 750 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Paint 750

Product Characteristics

Description

Hempel High-performance Epoxy High-build 750 is a self-priming high-solids epoxy coating combining high-performance amine and polyamide. Specially designed for offshore and severely corrosive environments, with excellent anti-corrosion performance; forms a hard, tough film ensuring lasting durability.

Recommended use

Hempel High-performance Epoxy High-build 750 is recommended as a high-build, self-priming intermediate coat for offshore and other demanding environments requiring fast handling and short overcoating times. This product resists mechanical stress and is suitable for new construction and maintenance, such as platforms, jackets, subsea pipelines and refineries, chemical plants etc. in severely corrosive environments. This product can also be used for maintenance work.

Service temperature

Certificates / approvals

Product features

Product safetyFlash point 26 °C

VOC content (after mixing the multi-component paint)

RegulationsValue
European Union192 g/L
USA (coatings)192 g/L
USA (regulatory)192 g/L
Canada192 g/L
China192 g/L
Hong Kong192 g/L
South Korea192 g/L

VOC values may vary with colour number; refer to Section 9 of the Safety Data Sheet. Never thin beyond local environmental regulations. According to specific legislation, see the explanatory notes provided on hempel.com or the local Hempel website. This product complies with the VOC requirements of mandatory national or recommended national standards; consult the company representative for details.

Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.

For professional use only.

Product Data

Product code47690
Product componentsBase 47699

Hardener 95069_______________________________

Standard colour* / codeMedium Grey 11480

Grey 11480 Paint 750

Volume solids80 ± 2%
density1.6 kg/L
Recommended dry film thickness150 µm

_______________________________Mica iron oxide (MIO) colour number / code MIO light grey 1C952 light grey 1C952

Volume solids80 ± 2%
density1.6 kg/L
Recommended dry film thickness150 µm

Surface Preparation

Cleanliness

New construction

Maintenance and repair

- Sound areas of the existing coating should be treated by blasting or water jetting to give a dense, uniform roughness, ensuring adhesion.

Roughness

For further details, refer to the separate Hempel document Surface Preparation Guide.

Application

Mixing Ratio

Base 47699 : Hardener 95069 (4.5 : 1 by volume)

Do not thin the components separately — thinning may be done after mixing. Keep thinning to a minimum. Stir thoroughly before use.

ThinnerHEMPEL's Thinner 08450
Cleaning solventHEMPEL's Tool Cleaner 99610

HEMPEL's Thinner 08450

Pot Life

Product temperature10°C20°C30°C
Pot Life2 h1 h¾ h
Pot life (spray)2 h1 h¾ h

Recommended method

ToolsMaximum thinning volumeApplication parameters
Airless Spray5%Nozzle pressure: 22.5 MPa; tip size: 0.48–0.58 mm
Brush/roller5%Not applicable.

If brush or roller application is used, multiple coats are needed to achieve the specified dry film thickness. The product requires heavy-duty spray equipment; the hose should be as short as possible. To reduce dry spray at high temperatures, additional thinning may be needed. At low paint temperatures, additional thinning may be needed, which will result in lower film build and slower drying. For brush or roller application, a suitable thinner or brushing agent may be used as needed. Spray parameters are indicative and can be adjusted according to site conditions. Pressure values apply to material at 20 °C. (*Consult the company representative if other application methods are needed!)

Film thickness

Specification rangeLowHighRecommended
Wet Film Thickness125 µm313 µm188 µm
Theoretical Spreading Rate8 m²/L3.2 m²/L5.3 m²/L

To achieve optimum performance, avoid excessive film thickness. Depending on the end use and service area, the product may be specified at film thicknesses other than those indicated. This will alter the spreading rate, drying and curing times and recoat interval.

Application conditions

Relative humidity

Drying and recoat

Product compatibility

Drying Time

Surface temperature-10°C0°C10°C20°C
Touch Dry8 h421
Hard Dry32 h1683
Fully cured56 days28147

Measured at 150 µm dry film thickness under standard conditions; see Hempel's explanatory notes.

Recoat

Hempel's specifications supersede all guidance shown in the recoat table.

Product name-10°C0°C10°C20°C
Atmospheric, severe
HEMPEL High-Performance High-Build Epoxy 750Minimum23 h11 h5 h2½ h
Maximum60 days30 days
HEMPEL's Polyurethane Mastic Topcoat 55610Minimum23 h11 h5 h2½ h
Maximum14 days7 days
Atmospheric, moderate
HEMPEL High-Performance High-Build Epoxy 750Minimum23 h11 h5 h2½ h
Maximum60 days30 days
HEMPEL's Polyurethane Mastic Topcoat 55610Minimum23 h11 h5 h2½ h
Maximum14 days7 days

Drying conditions

- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.

Recoat notes

Others

- Epoxy coatings have an inherent tendency to chalk, fade and discolour; this does not affect coating performance.

Storage

Shelf Life

Ambient temperature25°C
Binder24 months
Curing agent12 months

When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. For advice, consult Hempel.

Storage conditions

- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Carbon footprint

GWP (Global Warming Potential)5.6 g CO₂e/m²

Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².

The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.

Calculated based on the standard colours defined in this PDS. Values may vary with colour.

Supplementary documents

For further information, refer to the Hempel website (https://www.hempel.com/service-and-support/technical-guidelines) or your local Hempel website:

NumberDocument descriptionLocation/Notes
3.PDSThis document

datasheet, which is also available for download at www.hempel.com.

This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):

1.Technical declarationProvides one-off specific advice for the requirements of a specific project
2.SpecificationsIssued for specific projects only
4.Explanatory notes to the PDSAvailable for download at www.hempel.com, containing information related to product test parameters
5.Application guideIf available, provided at www.hempel.com
6.General technical guidelines (e.g. application and surface preparation)

If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating

View all HEMPEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery