HEMPEL Polyurethane High-Build Topcoat 55610 is a polyurethane coating used as a topcoat. HEMPEL Polyurethane High-Build Topcoat 55610 is recommended as a VOC-compliant high-build topcoat for the protection of structural steel in severely corrosive environments. HEMPEL Polyurethane High-Build Topcoat 55610 is a glossy polyurethane topcoat cured with aliphatic isocyanate. Parameters on this page: volume solids 67 ± 2%, dry film thickness 80 µm, theoretical spreading rate 8.3 m²/L. Comparable models from the same brand: HEMPEL Polyurethane High-Build Topcoat 55613, HEMPEL Polyurethane High-Build Topcoat 5561B, HEMPEL Polyurethane Matt Topcoat 552C0.
Parameter source: HEMPEL original technical data sheet (TDS) for HEMPEL Polyurethane High-Build Topcoat 55610; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 67 ± 2% |
|---|---|
| Dry Film Thickness | 80 µm |
| Theoretical Spreading Rate | 8.3 m²/L |
| VOC | 320 g/L (China) |
| Density / Specific Gravity | 1.4 kg/L |
| Number of Components | Two-component |
| Flash Point | 31°C |
| Thinner | HEMPEL's Thinner 08080 |
| Colour / Appearance | White 10000 * |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
55610
HEMPEL Polyurethane High-Build Topcoat 55610 is a glossy polyurethane topcoat cured with aliphatic isocyanate. The product has excellent gloss and colour retention and contains zinc phosphate.
Complies with EU Directive 2004/42/EC, the Paints Directive on limiting volatile organic compounds: subcategory j.
HEMPEL Polyurethane High-Build Topcoat 55610 is recommended as a VOC-compliant high-build topcoat for the protection of structural steel in severely corrosive environments. In C2 and C3 environments, the product can be specified as a single-coat system applied directly to metal. It can also be applied directly to galvanised steel.
- When used as part of the specified coating system, it is approved as a low flame-spread material. For further details, see the Declaration of Conformity at hempel.com.
- Third-party verified, product-specific Environmental Product Declaration (Type III EPD, ISO 14025, EN 15804)
- For ATEX environments: contact Hempel A/S for further information before specifying and using. The product is formulated with special conductive pigments in only the following shades, enabling coating systems meeting the requirements of ISO 80079-36:2016 for explosive atmospheres (ATEX): 95000, 95010, 95020, 95030, 95040, 95050.
Edition 6, System 1. Edition 7, System 1A, 1B.
| Product safety | Flash point 31 °C |
|---|
| Regulations | Value |
| European Union | 320 g/L |
| USA (coatings) | 320 g/L |
| USA (regulatory) | 320 g/L |
| Canada | 320 g/L |
| China | 320 g/L |
| Hong Kong | 320 g/L |
| South Korea | 320 g/L |
Depending on specific legislation, see the explanatory notes provided on the Hempel website hempel.com or the local Hempel website. Volatile organic compound (VOC) values may vary by shade; refer to Section 9 of the safety data sheet. ª EU Directive 2004/42/CE. In accordance with EPA Method 24. This product complies with the VOC requirements of national mandatory or national recommended standards; consult the company representative for details.
Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.
For professional use only.
| Product code | 55610 |
|---|---|
| Product components | Base 55619 |
Curing agent 97050
| Standard colour / code | White 10000 * |
|---|
55610 is available in other colours through the company's tinting system
| Gloss | |
|---|---|
| Volume solids | 67 ± 2% |
| density | 1.4 kg/L |
| Recommended dry film thickness | 80 µm |
_______________________________
| Aluminium colour / code | Aluminium Grey 19002 |
|---|
Refer to the Hempel Guide for Aluminium-containing Coatings.
| Volume solids | 58 ± 2% |
|---|---|
| density | 1.1 kg/L |
| Recommended dry film thickness | 80 µm |
- Abrasive blast clean to Sa 2½ (ISO 8501-1) / SP 10 (SSPC) / NACE No.2 minimum.
For further details, refer to the separate Hempel document Surface Preparation Guide.
Base 55619 : Curing agent 97050 (7 : 1 by volume)
Stir thoroughly before use.
| Thinner | HEMPEL's Thinner 08080 |
|---|---|
| Cleaning solvent | HEMPEL's Thinner 08080 |
| Product temperature | 20°C | 10°C | 30°C |
| Pot Life | 2 h | 3½ h | 1 h |
55610
| Tools | Maximum thinning volume | Application parameters |
| Airless Spray | 5% | Nozzle pressure: 17.5 MPa; nozzle size: 0.43–0.53 mm |
If brush or roller application is used, multiple coats are required to achieve the specified dry film thickness. Never thin beyond the range permitted by local environmental regulations. For brush or roller application, a suitable thinner or brushing agent may be used as required. HEMPEL brush/roller additive 99140 may be used to improve flow and levelling. Consult Hempel for advice. Spray parameters are indicative and may be adjusted to site conditions. Pressure figures apply to material at 20 °C. (*For other application methods, consult the company representative.)
| Specification range | Low | High | Recommended |
| Wet Film Thickness | 75 µm | 187 µm | 120 µm |
| Theoretical Spreading Rate | 13 m²/L | 5.3 m²/L | 8.3 m²/L |
To achieve optimum performance, avoid excessive film thickness.
During and for a period after application, film formation may be adversely affected by light rain, high humidity and/or condensation: '8 h, 20 °C/68 °F'.
- Ideal spray performance is obtained at paint temperatures of 15–30 °C [59–86 °F]; outside this range, additional thinning may be required.
| Surface temperature | 10°C | 20°C | 30°C |
| Touch Dry | 120 min | 90 | 60 |
| Surface Dry | 11 h | 3½ | 2 |
| Hard Dry | 12 h | 5 | 3 |
| Fully cured | - days | 7 | 5 |
Measured at 80 µm dry film thickness under standard conditions; see Hempel's explanatory notes.
Recoat times are for reference only for products of the same generic chemical composition at the recommended dry film thickness (DFT).
For further information, refer to Hempel's specifications.
- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.
55610
| Ambient temperature | 25°C |
| Binder | 36 months |
| Curing agent | 24 months |
When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. The shelf life stated on the product label is determined according to local climatic conditions. For advice, consult Hempel.
- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| GWP (Global Warming Potential) | 8 g CO₂e/m² |
|---|
Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².
The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.
| Number | Document description | Location/Notes |
| 3. | PDS | This document |
datasheet, which is also available for download at www.hempel.com.
Calculated based on the standard colours defined in this PDS. Values may vary with colour.
More information is available at the Knowledge Centre: https://www.hempel.com/knowledge-center. The following documents are in the “Technical Guidelines” section:
https://www.hempel.com/knowledge-center/technical-guidelines Hempel
This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):
| 1. | Technical declaration | Provides one-off specific advice for the requirements of a specific project |
| 2. | Specifications | Issued for specific projects only |
| 4. | Explanatory notes to the PDS | Available for download at www.hempel.com, containing information related to product test parameters |
| 5. | Application guide | If available, provided at www.hempel.com |
| 6. | General technical guidelines (e.g. application and surface preparation) |
If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.
The factory item codes of HEMPEL Polyurethane High-Build Topcoat 55610 are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.
| Item No. | Colour / colour code | Packaging Specifications |
|---|---|---|
| 55610-17210 RAL7021 | — | 20 L |
| 55610-57030 RAL2003 | — | 20 L |
| 55610-17750 RAL7045 | — | 20 L |
| 55610-11480 | — | 20 L |
| 55610-17630 RAL9003 | — | 17.5 L + 2.5 L |
| 55610-10170 RAL9010 | — | 20 L |
This model has a total of6item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.