HEMPEL's Solvent-free Epoxy Tank Lining 400

Quick Specs

HEMPEL Solvent-free Epoxy Tank Lining 400 is an epoxy coating. It resists a wide range of chemicals, including but not limited to: crude oil, refined hydrocarbons, aviation fuel, gasoline (petroleum)/ethanol blends, biodiesel, aromatic and aliphatic solvents, produced water and aqueous solutions. Crude oil/water mixtures at temperatures up to 60 °C [140 °F] can be applied in a single pass with a single-leg airless pump, and the coating can be put into service in less than 72 h. Parameters on this page: volume solids 100 ± 2%, dry film thickness 500 µm, theoretical spreading rate 2 m²/L.

Parameter source: HEMPEL original technical data sheet (TDS) "HEMPEL Solvent-free Epoxy Tank Lining 400"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100 ± 2%
Dry Film Thickness500 µm
Theoretical Spreading Rate2 m²/L
VOC25 g/L (China)
Density / Specific Gravity1.4 kg/L
Number of ComponentsTwo-component
Flash Point70°C
Colour / AppearanceLight blue 36641 **
GlossSemi-gloss

Browse Similar Models by CategoryThis model belongs to: Epoxy

FAQ

What dry film thickness is typically applied for HEMPEL Solvent-free Epoxy Tank Lining 400?
The typical dry film thickness of HEMPEL Solvent-free Epoxy Tank Lining 400 is 500 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of HEMPEL Solvent-free Epoxy Tank Lining 400?
The theoretical spreading rate of HEMPEL Solvent-free Epoxy Tank Lining 400 is 2 m²/L; actual consumption is adjusted according to substrate roughness, application losses and colour hiding power.
What is the volume solids of HEMPEL Solvent-free Epoxy Tank Lining 400?
The volume solids of HEMPEL Solvent-free Epoxy Tank Lining 400 is 100 ± 2%.
What is the VOC of HEMPEL Solvent-free Epoxy Tank Lining 400?
The VOC of HEMPEL Solvent-free Epoxy Tank Lining 400 is 25 g/L (China).
What is the gloss of HEMPEL Solvent-free Epoxy Tank Lining 400?
The gloss of HEMPEL Solvent-free Epoxy Tank Lining 400 is semi-gloss.
What is the flash point of HEMPEL Solvent-free Epoxy Tank Lining 400?
The flash point of HEMPEL's Solvent-free Epoxy Lining 400 is 70 °C; storage, transport and application shall be carried out in accordance with the product Safety Data Sheet.
Which standards apply to HEMPEL's Solvent-free Epoxy Lining 400?
As recorded in the technical data on this page: new construction: abrasive blast cleaning to a minimum of Sa 2½ (ISO 8501-1) / SP 10 (SSPC) / NACE No.2; roughness: surface roughness Medium (G) (ISO 8503-2). For more details, please refer to the separate HEMPEL document “Surface Preparation Guide”. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can HEMPEL's Solvent-free Epoxy Lining 400 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Coating 400

Product Characteristics

Description

HEMPEL's Solvent-free Epoxy Lining 400 is a high-performance epoxy lining. With a solids content of 100%, it can be applied at high film thickness and provides chemical resistance under long-term immersion conditions.

Crude oil/water mixtures resistant to temperatures up to 60 °C [140 °F] can be applied in a single pass using a single-leg airless pump and can be put into service in less than 72 h. It can also be used to create glass fibre reinforced lining systems.

Recommended use

Used as a lining for new tanks and pipelines, or for maintenance.

Resistant to a wide range of chemicals, including but not limited to: crude oil, refined hydrocarbons, aviation fuel, gasoline (petroleum)/ethanol blends, biodiesel, aromatic and aliphatic solvents, produced water and aqueous solutions.

Recommended for use in various markets including, but not limited to, oil and gas, power generation, and water and wastewater treatment.

This product is available in clear colour 00002, suitable for glass fibre lining systems, with a volume solids of 96% ± 2.

Service temperature

Product safetyFlash point 70 °C

VOC content (after mixing the multi-component paint)

RegulationsValue
European Union25 g/L
USA (coatings)25 g/L
USA (regulatory)25 g/L
Canada25 g/L
China25 g/L
Hong Kong25 g/L
South Korea25 g/L

Subject to specific legislation; see the explanatory notes on the Hempel website hempel.com or your local Hempel website. VOC values may vary with colour; refer to Section 9 of the Safety Data Sheet. This product complies with the VOC requirements of national mandatory or recommended standards; consult the company representative for details.

Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.

For professional use only.

Product Data

Product code37810
Product componentsBase 37819

Curing Agent 9780S

Standard colour* / codeLight blue 36641 **
GlossSemi-gloss
Volume solids100 ± 2%
density1.4 kg/L
Recommended dry film thickness500 µm

Surface Preparation

Cleanliness

New construction

- Abrasive blast clean to Sa 2½ (ISO 8501-1) / SP 10 (SSPC) / NACE No.2 minimum.

Maintenance and repair

Roughness

For further details, refer to the separate Hempel document Surface Preparation Guide.

Application

Mixing Ratio

Base 37819 : Curing agent 9780S (3 : 1 by volume)

Stir thoroughly before use. Thinning is not permitted.

Thinner

No thinning required

Cleaning solventHEMPEL's Tool Cleaner 99610

Pot Life

Product temperature20°C10°C30°C
Pot Life50 min80 min20 min

Recommended method

ToolsMaximum thinning volumeApplication parameters
Airless SprayNo thinning requiredNozzle pressure: 20 MPa; nozzle size: 0.53–0.74 mm
Brush/rollerNo thinning required​-

If brush or roller application is used, several coats may be required to achieve the specified dry film thickness. For tank linings, brush and roller application must be limited to touch-up, repair areas or minor repairs. Spray parameters are indicative and may be adjusted to suit site conditions. Pressure figures apply to the material at 20 °C. (*For other application methods, consult the company representative.)

Film thickness

Specification rangeLowHighRecommended
Dry Film Thickness300 µm750 µm500 µm
Wet Film Thickness301 µm754 µm502 µm
Theoretical Spreading Rate3.3 m²/L1.3 m²/L2 m²/L

Depending on the end use and service area, the product may be specified at film thicknesses other than those indicated. This will alter the spreading rate, drying and curing times and recoat interval. To achieve optimum performance, avoid excessive film thickness.

Application conditions

Relative humidity

Drying and recoat

Product compatibility

Drying Time

Surface temperature10°C20°C30°C40°C
Touch Dry8 h421
Hard Dry24 h1252½
Fully cured7 days321

Measured at 500 µm dry film thickness under standard conditions; see Hempel's explanatory notes.

Recoat

Hempel's specifications supersede all guidance shown in the recoat table.

Product name10°C20°C30°C40°C
Immersion
HEMPEL's Solvent-free Epoxy Lining 400Minimum8 h4 h2 h60 min
Maximum30 days21 days14 days

Recoat times are for reference only for products of the same generic chemical composition at the recommended dry film thickness (DFT).

For further information, refer to Hempel's specifications.

Drying conditions

- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.

Recoat notes

- For tank linings, if the maximum recoat interval is exceeded, roughen the surface by blasting to ensure intercoat adhesion.

Others

- Epoxy coatings have an inherent tendency to chalk, fade and discolour; this does not affect coating performance.

Storage

Shelf Life

Ambient temperature25°C
Binder18 months
Curing agent18 months

When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. The shelf life stated on the product label is determined according to local climatic conditions. For advice, consult Hempel.

- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Carbon footprint

Dry Film Thickness1 µm
GWP (Global Warming Potential)6.6 g CO₂e/m²

Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².

The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.

Calculated based on the standard colours defined in this PDS. Values may vary with colour.

Supplementary documents

More information is available at the Knowledge Centre: https://www.hempel.com/knowledge-center. The following documents are in the “Technical Guidelines” section:

https://www.hempel.com/knowledge-center/technical-guidelines Hempel

NumberDocument descriptionLocation/Notes
3.PDSThis document

datasheet, which is also available for download at www.hempel.com.

This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):

1.Technical declarationProvides one-off specific advice for the requirements of a specific project
2.SpecificationsIssued for specific projects only
4.Explanatory notes to the PDSAvailable for download at www.hempel.com, containing information related to product test parameters
5.Application guideIf available, provided at www.hempel.com
6.General technical guidelines (e.g. application and surface preparation)

If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating

View all HEMPEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery