Hempel Epoxy Paint 35490 is an epoxy paint. It is used as a heavy-duty coating for steel and concrete structures exposed to severely corrosive environments and/or impact, such as splash zones and decks. Hempadur Spray-Guard 35490 is a solvent-free two-component epoxy resin coating containing heavy-duty anti-slip aggregate. Parameters on this page: volume solids 100%, dry film thickness 2500 µm, theoretical spreading rate 0.4 m²/L. Comparable products from the same brand: Hempel Fiber-reinforced Epoxy Paint 47510, Hempel Multi-purpose Epoxy High-build Paint 500 Winter Grade, Hempel Multi-purpose Epoxy High-build Paint 500.
Parameter source: HEMPEL original technical data sheet (TDS) "Hempel Epoxy Paint 35490"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% |
|---|---|
| Dry Film Thickness | 2500 µm |
| Theoretical Spreading Rate | 0.4 m²/L |
| VOC | 0 g/L (China) |
| Density / Specific Gravity | 1.8 kg/L |
| Number of Components | Two-component |
| Flash Point | 60°C |
| Colour / Appearance | Green 41690 ** |
| Gloss | Semi-gloss |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Hempadur Spray-Guard 35490 is a solvent-free two-component epoxy resin coating containing heavy-duty anti-slip aggregate. After curing, it forms a hard, firm and well-adhering protective coating.
It is used as a heavy-duty coating for steel and concrete structures exposed to severely corrosive environments and/or impact, such as splash zones and decks.
Edition 6, System 4. Edition 7, System 4A.
| Product safety | Flash point 60 °C |
|---|
| Regulations | Value |
| European Union | 0 g/L |
| USA (coatings) | 0 g/L |
| USA (regulatory) | 0 g/L |
| Canada | 0 g/L |
| China | 0 g/L |
| Hong Kong | 0 g/L |
| South Korea | 0 g/L |
Subject to specific legislation; see the explanatory notes on the Hempel website hempel.com or your local Hempel website. VOC values may vary with colour; refer to Section 9 of the Safety Data Sheet. This product complies with the VOC requirements of national mandatory or recommended standards; consult the company representative for details.
Handle with care. Before and during use, observe the safety labels on the packaging and paint containers and comply with all local and national safety regulations. Consult the Hempel Safety Data Sheet and Product Data Sheet for the product at all times.
For professional use only.
| Product code | 35490 |
|---|---|
| Product components | Base 35499 |
Hardener 95690
| Standard colour* / code | Green 41690 ** |
|---|---|
| Gloss | Semi-gloss |
| Volume solids | 100% |
| density | 1.8 kg/L |
| Recommended dry film thickness | 2500 µm |
For further details, refer to the separate Hempel document Surface Preparation Guide.
Base 35499 : Hardener 95690 (5.6 : 1 by volume)
Stir thoroughly before use. Thinning is not permitted.
| Cleaning solvent | HEMPEL's Tool Cleaner 99610 |
|---|
| Product temperature | 20°C | 25°C | 30°C |
| Pot Life | 60 min | 45 min | 30 min |
(*For other application methods, consult the company representative.)
| Specification range | Low | High | Recommended |
| Dry Film Thickness | 1000 µm | 5000 µm | 2500 µm |
| Wet Film Thickness | 1000 µm | 5000 µm | 2500 µm |
| Theoretical Spreading Rate | 1 m²/L | 0.2 m²/L | 0.4 m²/L |
To obtain optimal performance, avoid excessive film thickness. On a suitable anti-corrosive primer, the product thickness may only be specified below 2500 µm (98 mils). For further details, contact Hempel.
- Previous coat: according to Hempel's specification. Recommended products: Hempadur Sealer 05990, Hempadur 15570, Hempaprime Multi 500 45950/3 - Subsequent coat: according to Hempel's specification. Recommended products: Hempathane
| Surface temperature | 20°C |
| Touch Dry | 5 h |
| Hard Dry | 8 h |
Dry film thickness 2500 µm determined under standard conditions; see Hempel's explanatory notes for details.
For further information, refer to Hempel's specifications.
- To achieve the stated drying times, adequate ventilation during application, drying and curing is essential.
| Ambient temperature | 25°C |
| Binder | 24 months |
| Curing agent | 36 months |
When stored in unopened original containers, shelf life is counted from the date of production. Thereafter, the product quality must be re-inspected. Storage at high temperatures may shorten the shelf life. For advice, consult Hempel.
- Store the product in accordance with the Safety Data Sheet, label and local regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Dry Film Thickness | 1 µm | |
| GWP (Global Warming Potential) | 3.7 g CO₂e/m² |
Carbon footprint is based on a 1 µm dry film thickness formed over a surface area of 1 m².
The scope includes raw materials, transport to the Hempel factory, the Hempel production process, and any volatile organic compounds (VOC) emitted during and after use of the product.
Calculated based on the standard colours defined in this PDS. Values may vary with colour.
| Number | Document description | Location/Notes |
| 3. | PDS | This document |
datasheet, which is also available for download at www.hempel.com.
For further information, refer to the Hempel website (https://www.hempel.com/service-and-support/technical-guidelines) or your local Hempel website:
- Application methods - General application guide. This Product Data Sheet (“PDS”) relates to the product supplied (the “Product”), and its content is updated from time to time. Accordingly, the buyer/applicator should refer to the PDS supplied with the relevant batch of product (rather than an earlier version). In addition to the PDS, the buyer/applicator may receive some or all of the specifications, declarations and/or guides shown below, which are also available for download from the “Products” page of the Hempel website (www.hempel.com) (hereinafter the “Supplementary Documents”):
| 1. | Technical declaration | Provides one-off specific advice for the requirements of a specific project |
| 2. | Specifications | Issued for specific projects only |
| 4. | Explanatory notes to the PDS | Available for download at www.hempel.com, containing information related to product test parameters |
| 5. | Application guide | If available, provided at www.hempel.com |
| 6. | General technical guidelines (e.g. application and surface preparation) |
If the information in the PDS and the supplementary documents is inconsistent, the information shall take precedence in the order listed above. In this case, contact the Hempel representative for clarification. In addition, the buyer/applicator must give full consideration to the relevant safety information accompanying each product. Hempel accepts no liability for any defects arising from application not carried out fully in accordance with the recommendations and requirements of the relevant PDS and supplementary documents. The information and terms in this disclaimer apply to this PDS, the supplementary documents and any other relevant documents provided by Hempel for this product. In addition, unless otherwise expressly agreed in writing, supply of the product and all technical support are subject to Hempel's General Conditions of Sale, Delivery and Service.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.