Enviroline 376F-30 Two-component Polycyclic Amine-cured Lining System belongs to Epoxy. Enviroline 376F-30 is also suitable for the external coating of buried pipelines. Enviroline 376F-30 is a solvent-free, two-component polycyclic amine-cured lining system utilizing advanced epoxy phenolic technology. For multi-component airless spray application, to achieve ideal results, the product may be heated before application: Component A (resin) to a maximum of 60 °C (140 °F), Component B (curing agent) to a maximum of 40 °C (105 °F). Parameters on this page: volume solids 100%, dry film thickness 500–1000 µm (20–40 mils), theoretical spreading rate 1.33 m²/L.
Parameter source: AKZONOBEL original technical data sheet (TDS) "Enviroline 376F-30 Two-component Polycyclic Amine-cured Lining System"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% |
|---|---|
| Dry Film Thickness | 500–1000 µm (20–40 mil) |
| Theoretical Spreading Rate | 1.33 m²/L |
| VOC | 0.20 lb/gal (25 g/L) US EPA Method 24 47 … |
| Density / Specific Gravity | 1.53 kg/L (12.8 lb/gal) |
| Number of Components | Two-component |
| Thinner | For specific advice, refer to the Enviroline Application Guide |
| Mixing Ratio | 2 parts : 1 part (by volume) |
| Colour / Appearance | Available in a limited range of colours, ENVIROLINE 376F- |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Enviroline 376F-30 is a solvent-free, two-component polycyclic amine-cured lining system utilizing advanced epoxy phenolic technology.
Provides internal corrosion protection for various steel storage tanks, industrial vessels, line shafts and pipelines against attack by the following products (but not limited to): crude oil, refined products (including unleaded gasoline blends and solvents) and biofuels below 93 °C (200 °F).
Enviroline 376F-30 is also suitable for the external coating of buried pipelines.
| Colour | Available in a limited range of colours, ENVIROLINE 376F- |
|---|---|
| Gloss | Not applicable 30 |
| Volume Solids | 100% |
| Typical thickness | Dry film thickness 500–1000 µm (20–40 mils) corresponds to wet film thickness 500–1000 µm (20–40 mils) |
| Theoretical Spreading Rate | At 750 µm DFT and the stated volume solids, 1.33 m²/L. At 30 mils DFT and the stated volume solids, 53 ft²/US gal |
| Practical Spreading Rate | Allowing for a suitable loss factor. For film thickness, see the Enviroline Application Guide |
| Application Methods | Plural-component airless spray, suitable for airless spray. Drying time; self-recoat interval |
| Temperature | Surface Dry | Hard Dry | Minimum | Maximum |
| 15°C (59°F) | 7 h | 12 h¹ | 12 h | 28 days² |
| 25°C (77°F) | 2 h | 4 h¹ | 2.5 h | 28 days² |
| 35°C (95°F) | 1 h | 2 h¹ | 2 h | 28 days² |
¹ Allow the film to reach sufficient strength before handling the coated steelwork. A Shore D hardness of 75–80 is recommended as a suitable value for return to service.
² If the maximum recoating interval is exceeded, thoroughly abrade the film surface with coarse abrasive paper, then perform solvent cleaning.
| Flash point (typical) | Component A 84 °C; Component B 54 °C |
|---|---|
| Product weight | 1.53 kg/L (12.8 lb/gal) |
| Volatile Organic Compounds | 0.20 lb/gal (25 g/L) US EPA Method 24. 47 g/kg EC Solvent Emissions Directive content (Council Directive 2010/75/EU). For further details, refer to the "Product Characteristics" section. |
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Where necessary, remove weld spatter and grind welds and sharp edges smooth.
Oil and grease must be removed in accordance with the SSPC-SP1 solvent cleaning standard.
Steel substrate: for optimum performance, Enviroline 376F-30 must be applied to a surface prepared by abrasive blasting to Sa3 (ISO 8501-1:2007) or SSPC-SP5. If not for use in high-temperature and/or severe environments, Enviroline 376F-30 may be applied to a surface with an abrasive blasting result of Sa2½ (ISO 8501-1:2007) or SSPC-SP10. For details, consult the International Protective Coatings department.
Recommended surface roughness 75–125 µm (3–5 mils).
Enviroline 376F-30 must be applied before oxidation of the steel surface occurs. If oxidation has occurred, all oxidized areas shall be re-blasted to the standards specified above.
Surface defects exposed by blasting must be ground, filled or treated by a suitable method.
Blast cleanliness can be maintained by dehumidification, or an approved temporary primer can be applied.
The concrete substrate must be well cured before flooring, lining or coating application. Refer to the concrete surface preparation guide for further information.
| Mixing | This product is supplied in two containers as one unit. The entire unit should be stored, mixed and applied in accordance with the Enviroline Application Guide. |
|---|---|
| Mixing ratio | 2 parts : 1 part (by volume) |
| Pot life | 40 °C (104 °F), 10 min |
| Plural-component airless spray | Recommended | For further information, refer to the Enviroline Application Guide. |
| Suitable for airless spray | Suitable | For further information, refer to the Enviroline Application Guide. |
| Air Spray | N/A |
(with pressure pot)
| Brush | Suitable | For small-area repair or touch-up of welds and edges. |
| Thinner | Generally not required | For specific advice, refer to the Enviroline Application Guide. |
| Cleaner | Enviroline 71C (or International GTA203) |
|---|---|
| Interruption of work | Do not leave material in hoses, guns or spray equipment. Thoroughly flush all equipment with... Enviroline 71C or International GTA203. Use immediately after mixing; it is recommended that material exceeding the pot life be discarded and freshly mixed. |
| Cleaning | Clean all equipment with Enviroline 71C or International GTA203 immediately after use. Periodically flushing spray equipment during the working day is good practice. The frequency of cleaning depends on the quantity sprayed, temperature and elapsed time, including delays. |
All surplus material and empty containers must be disposed of in accordance with local laws and regulations.
Read the Enviroline Application Guide carefully before use.
This datasheet provides a brief guide to the use of Enviroline 376F-30. The requirements of a specific project depend on the end use and service conditions of the tank or vessel. Always consult the International Protective Coatings department to confirm the suitability of Enviroline 376F-30 with the stored product.
Always follow the detailed coating specification recommended by the International Paint Protective Coatings division.
Touch-up is a fundamental requirement of good working practice; it should be part of any lining system.
For heavily pitted or porous steel, apply about 50% of the required film thickness by spray, then immediately roll with a short-nap roller or squeegee to work the coating into the bottom of pits.
For plural-component airless spray, the product may be heated before application for best results: Component A (resin) to a maximum of 60 °C (140 °F), Component B (curing agent) to a maximum of 40 °C (105 °F). For airless spray, heating each component to 35–37 °C (95–100 °F) before mixing gives optimum performance.
The temperature of the surface to be coated must be at least 3 °C (5 °F) above the dew point.
For the ideal temperature conditions, see the table below. Throughout curing, in addition to meeting these conditions, adequate ventilation must be maintained.
Substrate; environment
| Ideal 21–49 °C (70–120 °F) | 21-38 °C(70-100°F) |
|---|---|
| Minimum 13 °C (55 °F) | 13 °C (55 °F). After the coating system is fully cured, check the minimum thickness of the system using a non-destructive magnetic gauge. The entire system must be free of pinholes and bare spots. The cured film must be free of sags, runs, drips, inclusions or other defects. All defects and deficiencies must be repaired. Repaired areas must be retested and fully cured before the lining is put into service. |
Although baking is not required in most applications, it may be used to accelerate curing or improve chemical resistance in extremely corrosive environments. For maximum chemical resistance, bake at 121 °C (250 °F) for at least 2 hours, or at 66 °C for 6–8 hours.
The maximum continuous dry heat resistance temperature of Enviroline 376F-30 is 177 °C (350 °F).
Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.
Although the low-molecular-weight reactive additive becomes part of the film when cured under normal ambient conditions, analysis by EPA Method 24 shows that it also affects the VOC value.
Enviroline 376F-30 should always be applied to a properly prepared substrate. When a primer is required as part of the coating system, consult the International Protective Coatings department for professional advice.
Enviroline 376F-30 is a single-coat system. Where necessary, it must only be self-recoated or self-repaired.
| For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.com | In the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate • Enviroline Application Guide. These sections are also available as separate publications on request. |
|---|
This product is intended for professional applicators in industrial use only.
All work, including the application and use of this product, must comply with the relevant national standards, laws and regulations on safety, health and environmental protection.
During application and the subsequent drying period (for common drying times, see the product data sheet), provide adequate ventilation to keep solvent concentrations within safe limits and prevent fire and explosion. Forced ventilation is required in confined spaces. During application and drying, personal ventilation and respiratory protection (e.g. air-fed hood or suitable filter mask) must also be provided.
Take the necessary measures to prevent skin and eye contact with the coating (e.g. protective clothing, gloves, goggles, mask, barrier cream).
Before use, read and follow the Material Safety Data Sheet and the Health and Safety section of the application procedure for this product (for two-component coatings, those of the base and curing agent).
If welding or cutting is performed on metal substrate previously coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation.
The specific safety measures depend on the application method and working environment. If these warnings or instructions are not fully understood or cannot be strictly observed, do not use the product and consult International Paint.
Warning: this product contains liquid epoxy and modified polyamines and may cause skin sensitisation if handled improperly.
| Packaging Specifications | Component A | Component B | ||
| Volume | Packaging | Volume | Packaging | |
| 4 US gal | 2.67 US gal | 5 US gal | 1.33 US gal | 2 US gal |
| 18 L | 12 L | 20 L | 6 L | 10 L |
For other packaging sizes, contact AkzoNobel.
| Packaging Specifications | Component A | Component B |
| 4 US gal | 81.5 lb | 45.2 lb |
| 18 L | 18.48 kg | 10.02 kg |
| Shelf life | At 25 °C (77 °F), the paint can be stored for 12 months if sealed intact, after which inspection is required. Store in a dry, cool place away from heat sources and ignition sources. |
|---|
The information given in this product data sheet is not exhaustive. Anyone who uses, for any purpose, any product other than those specifically recommended in this data sheet without first obtaining our written confirmation does so at their own risk as regards the suitability of the product for the intended purpose. Although to the best of our knowledge all advice or statements given about the product (whether in this data sheet or otherwise) are correct, we cannot control the quality or condition of the substrate, nor the many factors affecting the use and application of the product. Accordingly, unless we specifically agree otherwise in writing, we accept no liability, to the maximum extent permitted by law, for any product performance problem arising, or for any loss or damage caused by use of the product. We hereby disclaim any warranty or representation, express or implied, arising by operation of law or otherwise, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. All products supplied and all technical guidance provided are subject to our standard terms and conditions of sale. You should obtain a copy of this document and read it carefully. The information contained in this product data sheet may be amended at any time in the light of experience and of our product development policy. Before using the product, it is the customer's responsibility to check with the local representative that the data sheet in their possession is the latest version.
This product data sheet is available on www.international-marine.com or www.international-pc.com and should be identical to this copy. If the version on the website differs from this one, the version on the website shall prevail.
©2023/3/30 AkzoNobel. All rights reserved.
www.envirolinegroup.comwww.international-pc.com
Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.