Chartek 1620CSP Epoxy Intumescent Cryogenic Spill and Fire Protection Coating is a fire protection paint. Suitable for protecting steel structures from prolonged cryogenic liquid spillage, hydrocarbon pool fires and jet fires. Tested to ANSI UL1709, BS 476-20/21 (Part 20 Appendix D), ISO TR 834-3 (1994), ISO 22899-1, ISO 20088-1/3, NORSOK-M501 - Revision 6 System 5A. Minimum maximum 6 hours 4 days mesh installation: if reinforcement mesh is needed, International Paint's HK-1 or HK-2 carbon fibre mesh should be installed according to the fire protection design with reference to the Chartek application manual. Parameters on this page: volume solids 100%, number of components: two.
Data source: AKZONOBEL original Technical Data Sheet (TDS), "Chartek 1620CSP Epoxy Intumescent Cryogenic Spill and Fire Protection Coating"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% |
|---|---|
| Dry Film Thickness | — |
| Theoretical Spreading Rate | — |
| VOC | 0.00 lb/gal (0 g/L) US EPA Method 24, 1 g/… |
| Density / Specific Gravity | 900 kg/m³ (56.185 lb/ft³) dual-pump spray application (IS… |
| Number of Components | Two-component |
| Thinner | For premixed application and trowel application only — refer to the Chartek 1620CSP application specification manual |
| Mixing Ratio | Always mix the whole unit of coating (for manual application methods, see the Chartek application specification manual) |
| Gloss | N/A |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Chartek 1620CSP is a high-performance, epoxy intumescent cryogenic spill and fire protection coating; it is a two-component, high-build coating providing excellent durability, corrosion resistance, fire protection and cryogenic protection.
Certified for fire protection of carbon steel and galvanized steel. Tested to ANSI UL1709, BS 476-20/21 (Part 20 Appendix D), ISO TR 834-3 (1994), ISO 22899-1, ISO 20088-1/3, NORSOK-M501 - Revision 6 System 5A.
Suitable for protecting steel structures from prolonged cryogenic liquid spillage, hydrocarbon pool fires and jet fires. Maintains the functional integrity of structures and process equipment for a specified period.
Mainly for high-risk environments such as the oil, gas, LNG, petrochemical and power generation industries.
CHARTEK1620CSP
| Gloss | N/A |
|---|---|
| Volume Solids | 100% |
| Typical thickness | Depending on the protection required. |
| Theoretical Spreading Rate | 1 kg of Chartek 1620CSP applied at a thickness of 1 mm covers an area of 1.1 m² (based on two-component spray application) |
| Practical Spreading Rate | Allowing for a suitable loss factor |
| Density | 900 kg/m³ (56.185 lb/ft³) dual-pump spray application (ISO 1183-1 (2019)) |
| Application Methods | Heated two-component airless spray. Drying time; self-recoat interval |
| Temperature | Surface Dry | Hard Dry | Minimum | Maximum |
| 15°C (59°F) | 8 h | 18 h | 4 h¹ | 1 week |
| 25°C (77°F) | 5 h | 16 h | 3 h¹ | 1 week |
| 40°C (104°F) | 2 h | 6 h | 2 h¹ | 4 days |
¹ The time during which the underlying coat can withstand wet film measurement. *Consult AkzoNobel for more information
| Flash point (typical) | Component A >106 °C (223 °F); Component B >106 °C (223 °F); mixed >106 °C (223 °F) |
|---|---|
| Volatile Organic Compounds | 0.00 lb/gal (0 g/L) US EPA Method 24, 1 g/kg, EU Solvent Emissions Directive (Council Directive 2010/75/EU). Coating hazard class GB 30981.2-S-Pb≤1000-NC, complying with GB 30981.2-2025. For more details, see the 'Product Characteristics' section. |
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000.
Blast cleaning: the surface preparation requirement for Chartek 1620CSP application is: blast clean to Sa 2½ (ISO 8501-1:2007) or SSPC-SP10. A sharp angular surface roughness of 50–75 µm (2–3 mils) is recommended.
Primer: for protection against cryogenic liquid spillage, it is important that the whole coating system has good thermal insulation and fire protection performance. The preferred primer should be epoxy or epoxy zinc powder type (e.g. Intergard 269, Intershield 300 or Interzinc 52/Intergard 269). International Paint publishes a list of qualified primers; primer thickness information should be checked against that list.
Damaged/repair areas: all areas to be repaired are preferably blasted to Sa 2.5 (ISO 8501-1:2007) or SSPC-SP10. However, areas smaller than 1 m² may be power tool cleaned to SSPC-SP11, with a clean surface having roughness. A roughness of 50–75 µm must be achieved. The recommended primer can then be applied before Chartek 1620CSP.
| Mixing | If using approved modified single-component airless spray equipment or trowel application for Chartek 1620CSP, first thoroughly mix one kit of Chartek 1620CSP. Each component must be stored at 20–30 °C (68–86 °F) for 24 hours, and thoroughly stirred with a power tool before mixing. |
|---|---|
| Mixing ratio | Always mix the whole unit of coating (for manual application methods, see the Chartek application specification manual) |
| Pot life | 15°C (59°F) | 25°C (77°F) |
| 90 min | 50 min |
The above data applies to trowel application. The pot life does not apply to dual-pump airless spray application, because the product is only mixed in a static mixer near the spray gun. For approved modified single-component airless spray equipment, the pot life will be correspondingly shortened according to the above data. Refer to the Chartek application guide.
| Plural-component airless spray | Recommended and preferred equipment: AkzoNobel-approved heated dual pump equipment |
|---|---|
| Suitable for airless spray | Recommended - for small areas only: use International Paint-approved modified single-component airless spray equipment, compression ratio at least 68:1, (see the Chartek application guide for more details), normally thinned up to 5%. |
| Trowel application | Applicable — for small-area repair only | Thinning ratio maximum 5% by weight |
| Thinner | International GTA123 | For premixed application and trowel application only — refer to the Chartek 1620CSP application specification manual |
| Cleaner | International GTA007 |
|---|---|
| Interruption of work | Do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International thinner. Once mixed, paint should not be resealed; if work is interrupted for too long, mix a fresh batch for application. |
| Cleaning | All equipment should be cleaned immediately after use with International thinner. Flushing spray equipment periodically during daily work is good practice. Cleaning frequency depends on the volume sprayed, temperature, spraying time, including delays, and other factors. |
All surplus paint and empty containers must be disposed of in accordance with the relevant local laws/regulations.
Throughout application, the following conditions must be present (or created): minimum air temperature: 10 °C (50 °F); maximum humidity: 85%; surface temperature: more than 3 °C (5 °F) above the dew point of the surrounding air. General: the surface must be clean, dry and free of contaminants, and can then be coated. Chartek 1620CSP should be applied by spray to ensure complete wetting of the substrate. If more than spray is used, the first coat should be thoroughly trowelled and rolled to achieve this. The better self-overcoating time for Chartek 1620CSP is after the minimum self-overcoating interval is reached, or before the coating has any chance of being contaminated.
When applying the recommended Chartek topcoat, the following overcoating intervals must be observed:
Minimum maximum
| 10°C (50°F) | 24 h; 7 days |
|---|---|
| 25°C (77°F) | 18 hours 7 days |
| 40°C (104°F) | 6 hours 4 days mesh installation: if reinforcement mesh is needed, International Paint's HK-1 or HK-2 carbon fibre mesh should be installed according to the fire protection design with reference to the Chartek application manual. Special fire scenarios, e.g. fires containing an expected jet fire period, may require specific mesh and film thickness. Detailed requirements must be elaborated according to the specific project, and approved by certification bodies such as LR or DNV. |
After mesh application, continue spraying Chartek 1620CSP to the required film thickness. Equipment must be equipment approved by International Paint Protective Coatings, used according to the detailed provisions in the Chartek application manual or the guidance of International Paint Protective Coatings field technical service engineers.
Applicator certification: only companies certified by AkzoNobel as qualified applicators may apply Chartek 1620CSP. These companies must be documented before application. Chartek 1620CSP application shall be carried out by the application company using qualified personnel trained in the correct application procedures. At minimum, site supervisors and QA/QC personnel shall hold individual qualifications and have attended the AkzoNobel Chartek applicator training course. This is the minimum requirement and must be documented in writing before application.
Inspection and quality assurance. This is the applicator's responsibility and must at least follow the procedures specified in the AkzoNobel Chartek QC manual. Technical service. Available from AkzoNobel and should be coordinated to be present at start of work. The applicator is responsible for ensuring AkzoNobel is notified of the start date.
Maximum surface operating temperature: when the temperature is between 80–120 °C (176–248 °F), a suitable thermal insulation layer, e.g. Intertherm 7050, should be used between the substrate and Chartek 1620CSP.
Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.
Chartek 1620CSP is normally applied over substrates with a suitable primer. Contact International Paint to confirm the correctness of the primer selection.
Chartek 1620CSP should be topcoated to meet the owner's colour scheme and appearance requirements.
Suitable topcoats are: Interfine 629HS; Interthane 990; Interzone 954
| For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.com | In the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate. These sections are also available as separate publications on request. |
|---|
This product must be applied at the production site by professional applicators in accordance with the recommendations in this manual, the Material Safety Data Sheet and the instructions on the container label. Do not use this product without first reviewing the Material Safety Data Sheet (MSDS) that International Paint provides for its customers.
All work related to the application and use of this product must be carried out in accordance with the relevant national health, safety and environmental standards and regulations.
If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation.
If in doubt about the suitability of this product for the intended use, consult AkzoNobel for further advice.
| Unit | Component A | Component B |
| Weight | ||
| 20 kg (44.1 lb) per unit | 14.2 kg (31.3 lb) | 5.8 kg (12.8 lb) |
| 50 kg (110.2 lb) per unit | 35.48 kg (78.2 lb) | 14.52 kg (32.0 lb) |
Supplied as a 20 kg (44.1 lb) unit, comprising one drum of Component A and one plastic drum of Component B. The Component A drum normally has spare volume to hold Component B, allowing thorough power-tool mixing before application.
Supplied as a 50 kg (110.2 lb) unit, comprising two full drums of Component A and one full drum of Component B, suitable for airless spray application.
For other packaging sizes, contact AkzoNobel.
| Unit | Component A | Component B |
| Weight | ||
| 20 kg (44.1 lb) per unit | 16.0 kg (35.2 lb) | 6.4 kg (14.1 lb) |
| 50 kg (110.2 lb) per unit | 39.1 kg (86.0 lb) | 16.3 kg (36.0 lb) |
| Shelf life | 1 year at room temperature. Store indoors, away from direct sunlight. The temperature range must be maintained between 1–30 °C (34–86 °F). |
|---|
The information given in this product data sheet is not exhaustive. Anyone who uses, for any purpose, any product other than those specifically recommended in this data sheet without first obtaining our written confirmation does so at their own risk as regards the suitability of the product for the intended purpose. Although to the best of our knowledge all advice or statements given about the product (whether in this data sheet or otherwise) are correct, we cannot control the quality or condition of the substrate, nor the many factors affecting the use and application of the product. Accordingly, unless we specifically agree otherwise in writing, we accept no liability, to the maximum extent permitted by law, for any product performance problem arising, or for any loss or damage caused by use of the product. We hereby disclaim any warranty or representation, express or implied, arising by operation of law or otherwise, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. All products supplied and all technical guidance provided are subject to our standard terms and conditions of sale. You should obtain a copy of this document and read it carefully. The information contained in this product data sheet may be amended at any time in the light of experience and of our product development policy. Before using the product, it is the customer's responsibility to check with the local representative that the data sheet in their possession is the latest version.
This product data sheet is available on www.international-marine.com or www.international-pc.com and should be identical to this copy. If the version on the website differs from this one, the version on the website shall prevail.
© 2026/5/27 AkzoNobel. All rights reserved.
www.international-pc.com
Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.