← Back to AkzoNobel brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Ceilcote 652 Lining Heavy-duty Anti-corrosive Lining

Quick Specs

Ceilcote 652 Lining Heavy-duty Tank Lining belongs to Vinyl Ester. When specific chemical-resistant protective protection is required, Ceilcote 652 Lining provides durable and reliable protection for tanks and trenches. Ceilcote 652 Lining is a heavy-duty lining that can be applied by trowel, providing protective protection for steel structures and concrete structures under immersion in highly corrosive media. (The second coat requires the use of a thin-film curing agent.) If the overcoating interval is exceeded, wipe with styrene to confirm whether overcoating is possible. Parameters on this page: Volume Solids 100% reactive, Dry Film Thickness 1500 µm (60 mil), Theoretical Spreading Rate 0.60 m²/L.

Parameter source: AKZONOBEL original technical data sheet (TDS) “Ceilcote 652 Lining Heavy-duty Tank Lining”; values such as spreading rate are converted according to TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100% active
Dry Film Thickness1500 µm (60 mils)
Theoretical Spreading Rate0.60 m²/L
VOC1.76 lb/gal (212 g/L) US EPA Method 24…
Density / Specific Gravity1.04 kg/L (8.7 lb/gal)
Number of ComponentsTwo-component
ThinnerDo not thin
Mixing Ratio1 L Part A : 20 ml Part B (1 gal Part…
GlossN/A

Browse Similar Models by CategoryThis model belongs to: Vinyl Ester

FAQ

How many components does Ceilcote 652 Lining have?
Ceilcote 652 Lining is a two-component product; use after mixing according to the mixing ratio in the "Application Data" table on this page.
What is the mixing ratio of Ceilcote 652 Lining?
The mixing ratio of Ceilcote 652 Lining is 1 L Part A : 20 mL Part B (1 gal Part…
What dry film thickness is typically applied for Ceilcote 652 Lining?
The conventional dry film thickness of Ceilcote 652 Lining is 1500 µm (60 mil); the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Ceilcote 652 Lining?
The theoretical spreading rate of Ceilcote 652 Lining is 0.60 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Ceilcote 652 Lining?
The volume solids of Ceilcote 652 Lining is 100% reactive.
What is the VOC of Ceilcote 652 Lining?
The VOC of Ceilcote 652 Lining is 1.76 lb/gal (212 g/L) US EPA Method 24…
What is the gloss of Ceilcote 652 Lining?
The gloss of Ceilcote 652 Lining is Not applicable.
What thinner is used for Ceilcote 652 Lining?
Recommended thinner for Ceilcote 652 Lining: Do not thin.
How is Ceilcote 652 Lining applied?
Application method for Ceilcote 652 Lining: float application, brush and roller; drying time and recommended topcoat recoating interval; surface preparation and the coating system are as described on this page.
Which standards does Ceilcote 652 Lining involve?
As recorded in the technical data on this page: GB 30981.2 (see the application instructions on this page); before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Ceilcote 652 Lining be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product description

Ceilcote 652 Lining is a heavy-duty lining that can be applied by trowel, providing protective protection for steel structures and concrete structures under immersion in highly corrosive media. The lining mainly consists of vinyl resin, inert fillers and reinforcing glass fibre. The lining resists attack by some dilute inorganic acids and some concentrated acids, such as phosphoric acid.

Intended use

When specific chemical-resistant protective protection is required, Ceilcote 652 Lining provides durable and reliable protection for tanks and trenches.

Its high chemical resistance also makes it suitable for secondary containment.

Application data

CEILCOTE Colour Grey 652 LINING

GlossN/A
Volume Solids100% active
Typical thicknessBase coat: (resin + powder) single coat 1500 µm (60 mils) dry film thickness, equivalent to 1765 µm wet film, theoretical coverage 1.27 m²/L (55 ft²/US gal). Laminate (resin-wetted reinforcement mesh layer): two coats, each 800 µm (32 mils), theoretical spreading rate 1.34 m²/L (50 ft²/US gal); press the surface mat into the surplus resin layer.

Topcoat: (resin only) two coats at a dry film thickness of 150 µm (6 mil) corresponding to a wet film thickness of 176 µm (7 mil), theoretical spreading rate 5 m²/L (200 ft²/US gal)

Practical Spreading RateAt a dry film thickness of 1500 µm and 85% volume solids, the theoretical spreading rate is 0.60 m²/L. At 60 mil dry film thickness and 85% volume solids, the theoretical spreading rate is 23 ft²/US gal. (For more details, see the 'Product Characteristics' section.)
Application MethodsTrowel, Brush, Roller drying time recommended topcoat overcoating interval
TemperatureSurface DryHard DryMinimumMaximum
10°C (50°F)60 min7 h12 h7 days¹
15°C (59°F)45 min6 h8 h7 days¹
25°C (77°F)45 min3 h4 h7 days¹
35°C (95°F)30 min2 h3 h7 days¹

¹ When the surface temperature exceeds 35 °C (95 °F) or the surface is exposed to sunlight, recoat as soon as the coating is hard enough to walk on, to avoid intercoat adhesion problems.

Regulatory compliance data

Flash point (typical)Component A 34 °C (93 °F)
Product weight1.04 kg/L (8.7 lb/gal)
Volatile Organic Compounds1.76 lb/gal (212 g/L) US EPA Method 24 g/kg EC Solvent Emissions Directive content Commission Directive 2010/75/EU coating hazard GB 30981.2-S-Pb≤1000-NC complies with GB 30981.2-2025. For more detailed information, see the "Product Characteristics" section.

Surface Preparation

All surfaces to be coated must be clean, dry and free of contamination. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Remove any oil and grease by solvent cleaning in accordance with SSPC-SP1.

For steel substrates in immersion, humid or high-temperature service, apply this product over a suitably primed surface blast cleaned to Sa 3 (ISO 8501-1:2007), SSPC-SP5 or NACE No.1. For dry or fume environments, blast cleaning to Sa 2½ (ISO 8501-1:2007), SSPC-SP10 or NACE No.2 is appropriate. Surface roughness must be at least 75 µm (3 mils).

Before applying a suitable primer, the concrete substrate must be fully cured. The concrete surface must be dry and pass the plastic sheet test (ASTM D4263). All surfaces to be coated must be clean, dry and free of accelerators, release agents, levelling agents, surface hardeners, efflorescence, grease, oil, dust, old coating and loose or spalled concrete. All concrete surfaces to be coated must be blast cleaned to remove laitance and obtain a rough surface. The surface tensile strength (ASTM D4541) must be at least 2 MPa (300 psi). For further information, refer to the concrete surface preparation specification.

Application

MixingCeilcote 652 lining must be mixed and applied in accordance with the detailed application instructions of the subsequent system.

The resin component is supplied as two cans per unit. Normally the whole unit is mixed. Once mixed, it shall be used within the specified pot life. (1) Shake Component A, then pour the whole cans of Component A and Component B together and mix thoroughly with a power stirrer. (2) Component C, the powder component, shall be added slowly while Components A and B are being stirred. For specific quantity requirements, refer to the product data section.

Mixing ratio1 L Part A : 20 ml Part B (1 gal Part A : 2½ fl oz Part B)
Pot life10°C (50°F)15°C (59°F)25°C (77°F)35°C (95°F)
60 min50 min30 min15 min
Suitable for airless sprayN/A
BrushRecommendedSuitable for wetting with resin and smoothing liquid surfaces
Roller applicationRecommendedSuitable for wetting with resin and smoothing liquid surfaces
Trowel applicationRecommendedFor applying the base coat
ThinnerDo not thin
CleanerCeilcote T-410 Solvent or MEK
Interruption of workUse immediately after mixing; if the pot life is exceeded, discard and mix a fresh batch.
CleaningClean immediately after use with T-410 Solvent.

All surplus material and empty containers must be disposed of in accordance with local regulations.

Product Characteristics

Before using the relevant Ceilcote system, read the detailed Application Guide.

Before work begins, International Paint provides a precise system for dry film thickness and number of coats.

Although Ceilcote 652 lining has an activity of 100%, the actual volume solids may be lower depending on application conditions; International Protective Coatings recommends an estimated spreading rate value of 85%.

The surface temperature must be at least 3 °C (5 °F) above the dew point. Ensure adequate ventilation during application and curing. Dehumidification, air conditioning and/or heating equipment may be necessary to control the environment.

At all stages of application, the surface, air and paint temperatures must be between 10 °C (50 °F) and 43 °C (110 °F).

The required powder grade and the amount of powder to be stirred into the resin per litre (and gallon) are as follows: S-1 powder 2.6–3.1 kg/L (22–26 lb/gal). The powder is added to the base coat only.

Application: 1. Using a trowel, apply a base coat of 1000–2000 µm (40–80 mil) (target 1500 µm, 60 mil).

2. Press the reinforcement mesh into the base coat without wrinkling or entrapping air, and wet out the mesh with resin until it becomes transparent.

3. Apply the second reinforcement mesh in the same way as step 2.

4. After steps 2 and 3, press the surface mat into the remaining resin and allow it to cure.

5. Apply two topcoats, each 150 µm (6 mil). (The second coat requires a film curing agent.) If the overcoating interval is exceeded, wipe with styrene to check whether overcoating is possible. If the surface feels 'slightly tacky', adhesion is acceptable. If it is not softened by styrene, sweep-blast or mechanically abrade the surface to obtain a matte, rough surface. Primed surfaces shall be dry and free from foreign matter before lining, coating or flooring application.

Following correct application procedures, Ceilcote 652 lining may be returned to service after the following time intervals: 10 °C (50 °F): 48 h; 20 °C (70 °F): 24 h; 35 °C (90 °F): 16 h. Ceilcote 652 lining is not intended for use as a decorative topcoat; colour stability is difficult to achieve.

Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.

Although the low-molecular-weight reactive additive becomes part of the film when cured under normal ambient conditions, analysis by EPA Method 24 shows that it also affects the VOC value.

System compatibility

Ceilcote 652 lining should always be applied over a correctly prepared primed surface. Suitable primers are as follows: Ceilcote 380 Primer

Supplementary information

For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.comIn the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate. These sections are also available as separate publications on request.

Safety precautions

This product is intended for professional applicators in industrial use only.

All work, including the application and use of this product, must comply with the relevant national standards, laws and regulations on safety, health and environmental protection.

During application and the subsequent drying period, provide adequate ventilation to keep solvent concentrations within safe limits and prevent fire and explosion (for general drying times, see the product data sheet). Forced ventilation is required in confined spaces. During application and drying, personal ventilation and/or respiratory protection (e.g. air-fed hood or suitable filter mask) must also be provided. Take the necessary measures to prevent skin and eye contact with the coating (e.g. protective clothing, gloves, goggles, mask, barrier cream).

Before use, read and follow the Health and Safety section of the Material Safety Data Sheet and the application procedure for the product (for two-component coatings, those of the base and curing agent).

If welding or flame cutting is performed on metal substrate coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation.

The specific safety measures depend on the application method and working environment. If these warnings or instructions are not fully understood or cannot be strictly observed, do not use the product and consult the International Paint Protective Coatings division.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
15 L14.71 L20 L0.29 L0.7 L
5 US gal5 US gal12.5 fl oz1 US pint

For other packaging sizes, contact AkzoNobel.

Shipping weight

Packaging SpecificationsComponent AComponent B
15 L17.06 kg0.39 kg
5 US gal47.8 lb1 lb

Powder packaging is generally 20 kg or 50 lb depending on place of production. For further information, consult International Paint.

Storage

Shelf lifeStore for 6 months at 20 °C (68 °F). Inspection is required thereafter. Store in a dry, cool environment, away from heat and ignition sources. During storage and transport, the temperature of the Ceilcote 652 lining initiator must not exceed 30 °C (90 °F). Refrigeration is recommended. Part A and Part B should be stored separately.

© 2026/5/26 AkzoNobel. All rights reserved.

All registered trademarks mentioned in this publication are licensed to or owned by AkzoNobel.

www.international-pc.com

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — Vinyl Ester

View all AKZONOBEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery