Effectively protects concrete and the embedded reinforcing steel from corrosion, loosening, spalling and mould growth caused by water penetration, sunlight, acid rain and seawater, thereby extending the service life of the building. Comparable products from the same brand: ZB95-11 solvent-free direct-to-metal coating, ZD18-12 coating for galvanized surfaces, ZD2190 heavy-duty marine anti-corrosion coating.
Parameter source: ZINDN original Technical Data Sheet (TDS) 'ZD100 Silane Impregnating Agent'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | — |
|---|---|
| Dry Film Thickness | — |
| Theoretical Spreading Rate | — |
| VOC | — |
| Density / Specific Gravity | g/ml 0.88 |
| Number of Components | — |
| Colour / Appearance | Colourless, transparent |
The manufacturer's datasheet for this model does not state the coating position or resin type, so it has not been assigned to the above categories. Browse similar products by category, orContact Usconfirm the coating system.
ZD100 Silane Impregnating Agent
This product is high-purity undiluted isobutyltriethoxysilane. The small-molecule structure penetrates cemented surfaces and permeates into the concrete, reacting chemically with moisture in the air and substrate exposed to acidic or alkaline environments to form a water-repellent treatment layer, restricting water ingress into the substrate. It provides water resistance, chloride resistance and UV resistance together with breathability. It effectively prevents substrate deterioration caused by water penetration, sunlight, acid rain and seawater attack, including corrosion, loosening, spalling and mould of concrete and internal steel reinforcement, and extends the service life of the building. Treated substrates have good water repellency and retain their original appearance. Alkaline environments, such as freshly poured concrete, promote the reaction and accelerate formation of the water-repellent layer.
Widely used in various reinforced concrete structures, such as commercial buildings (interior and exterior walls, roofs and floors of high-grade buildings), car parks, garages, warehouses and cold stores, swimming pools, expressways, bridge structures, expressways, ports and wharves, and offshore engineering. Particularly suitable for high-grade concrete structures in severe environments, roads, overpasses, utility poles, sewage treatment tanks of sewage treatment plants, landfill sites and plateau regions with large temperature differences subject to salt spray and de-icing salt attack. A product recommended by national anti-corrosion codes for the concrete industry.
3. Physical Parameters
The following data are for guidance only and shall not be used to prepare technical specifications.
| Test | Unit / Result |
|---|---|
| CAS No. | 17980-47-1 |
| Purity | % ≥98.9 |
| Colour | Colourless, transparent |
| Density (25°C) | g/ml 0.88 |
| Refractive index (n20 d,,25°C,) | 1.4 |
1. Clean the substrate surface before use. All surfaces to be treated shall be free from standing water, dirt, dust, oil and other contaminants.
2. Apply with a sealed spray gun, roller or brush. For brush or roller application, apply repeatedly to keep the surface wet for several minutes; for sealed spray gun application, continue spraying until the substrate is thoroughly saturated; for vertical surfaces, spray from the bottom upwards to a run-down length of 15~20 cm.
3. Before use, carry out an application test on each surface to be treated to confirm compatibility and achieve the desired water-repellent effect.
4. Keep the surface as dry as possible to achieve the desired penetration effect.
1. This product is flammable and releases ethanol on curing. Observe safety precautions; do not expose to air. Store and use with adequate ventilation, away from sparks, heat sources and open flames.
2. Exposure to water before use may cause the product to cure in the container.
3. Do not use on structures under hydrostatic pressure. Do not use at temperatures of 4°C or below, or above 40°C.
4. During application, personnel shall wear goggles and protective gloves as required. In case of accidental inhalation, move the person to fresh air immediately. In case of skin or eye contact, wash immediately with water for 15 min, remove contaminated clothing and shoes, and seek medical attention promptly.
This product is packed in 20 kg containers; shelf life is 2 years in an environment of 0 7. Safety Information The information provided herein is true and accurate. As the conditions and methods of use of the Company's products are beyond the control of the Company, this information Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails. For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.FAQ
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.