← Back to T&H brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Epoxy Silicone Heat-resistant Anti-corrosive Coating XH7617

Quick Specs

Epoxy Silicone Heat-resistant Anti-corrosion Coating XH7617 belongs to heat-resistant coatings, epoxy coating system. Suitable for high-temperature anti-corrosion protection of pipelines and equipment at medium temperatures in petrochemical plants, chemical plants, power plants, steel plants and other facilities, particularly suitable for heat-resistant anti-corrosion under insulation. Parameters on this page: volume solids 48 ± 2%, dry film thickness 40/60/80 µm, theoretical spreading rate 6 m²/L.

Parameter source: T&H original technical data sheet (TDS) for Epoxy Silicone Heat-resistant Anti-corrosive Coating XH7617; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids48 ± 2%
Dry Film Thickness40/60/80 µm
Theoretical Spreading Rate6 m2/L
VOC470g/L
Density / Specific Gravity1.3 kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner0-10%
Mixing RatioBase : curing agent = 20:1 (by weight), 93:7 (by volume)

Browse Similar Models by CategoryThis model belongs to: Heat-resistant, Epoxy, Silicone

FAQ

What is the mixing ratio of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The mixing ratio of Epoxy Silicone Heat-resistant Anti-corrosive Coating is Base:Hardener = 20:1 (by weight), 93:7 (by volume).
What dry film thickness is typically applied for Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The conventional dry film thickness of Epoxy Silicone Heat-resistant Anti-corrosive Coating is 40/60/80 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The theoretical spreading rate of Epoxy Silicone Heat-resistant Anti-corrosive Coating is 6 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The volume solids of Epoxy Silicone Heat-resistant Anti-corrosive Coating is 48 ± 2%.
What is the VOC of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The VOC of Epoxy Silicone Heat-resistant Anti-corrosive Coating is 470g/L.
What is the gloss of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The gloss of Epoxy Silicone Heat-resistant Anti-corrosive Coating is Not applicable.
What thinner is used for Epoxy Silicone Heat-resistant Anti-corrosive Coating?
Recommended thinner for Epoxy Silicone Heat-resistant Anti-corrosive Coating: 0-10%.
What is the flash point of Epoxy Silicone Heat-resistant Anti-corrosive Coating?
The flash point of Epoxy Silicone Heat-resistant Anti-corrosive Coating is 25°C; storage, transport and application shall follow the product safety data sheet.
Which standards are involved for Epoxy Silicone Heat-resistant Anti-corrosive Coating?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Epoxy Silicone Heat-resistant Anti-corrosive Coating be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

This product is composed of silicone-modified epoxy resin, heat-resistant pigments (fillers), additives, solvents and curing agent and other components. Long-term heat resistance temperature 250 °C, short-term maximum heat resistance temperature 300 °C. Suitable for high-temperature anti-corrosion protection of pipelines and equipment at medium temperatures in petrochemical plants, chemical plants, power plants, steel plants and other facilities, particularly suitable for heat-resistant anti-corrosion under insulation.

Product Characteristics

Basic physical and chemical data

ColourAluminium grey
GlossN/A
density1.3 kg/L
Volume Solids48±2%
Volatile Organic Compounds470g/L
Flash Point25°C
Mixing ratioBase : curing agent = 20:1 (by weight), 93:7 (by volume)

Application parameters

Typical dry film thickness40µm
Recommended dry film thickness40 (1 coat) to 200 (50×4 coats) µm, depending on system requirements.
Induction time (20 °C)10~15min

Application Methods

Thinner quantity (by volume)Airless spray 0–5%Air spray 10–20%Roller or brush 0–10%
Recommended nozzle size0.38~0.43mm1.5~2.5mmNone
Recommended spray pressure15~20MPa0.3~0.6MPaNone
Application suitabilityRecommendedApplicable

Theoretical Spreading Rate

Dry film thickness (µm)406080
Wet film thickness (µm)84125167
Theoretical spreading rate (m²/L)1286

Application data (typical dry film thickness 40 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C2h24h4h24h
15°C1h12h3h24h/
25°C30min8h2h12h
40°C15min4h1.5h12h

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free from contamination. Before application, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. The product may be applied directly to metal substrates prepared to Sa2½ or St3, or over the recommended heat-resistant anticorrosive primer. When used over a heat-resistant primer, it shall be applied within the specified overcoating interval, and the primer surface shall be dry and free from contamination. When applied over other heat-resistant old coatings, chalk, grease and other contaminants shall be removed by appropriate methods. In cracked or damaged areas, the substrate shall be prepared to Sa2½ or St3 and the primer repaired before applying the product.

Precautions

1. During application, ensure ventilation and exhaust, keep away from ignition sources, and wear masks, gloves and other protective equipment; adequate ventilation shall also be maintained during curing. 2. When mixing paint, first stir the paint uniformly, add the hardener in the specified ratio and stir uniformly, then adjust the thinner amount according to application requirements and temperature changes, and stir thoroughly. As the product ratio is large, weighing instruments shall be used when the mixing quantity is small; volumetric measuring devices cannot accurately prepare the paint by volume. 3. The film may show slight discolouration and yellowing when exposed to high temperature for a long time. The maximum heat resistance temperature depends on the dry film thickness of the coating; the lower the thickness, the higher the maximum heat resistance temperature. 4. Excessive coating thickness or too short a recoating interval will seriously affect the drying and curing, heat resistance, recoating performance and handling time of the coating. 5. After long-term exposure of the product coating, before recoating, ensure that the old film surface is free of contaminants and sand the surface before applying subsequent coatings. 6. When applied over inorganic zinc silicate primer, ensure the primer is fully cured (MEK test at least grade 4). 7. Thick films of this product must be thoroughly dried and cured for at least 14 days before being put into service; otherwise, the incompletely cured coating cannot achieve good temperature resistance, and the film may peel or detach during heating. 8. During application and curing, the substrate temperature must be above 5°C and at least 3°C above the dew point, and the relative humidity shall not exceed 85%. Avoid application on surfaces above 40°C; otherwise defects such as blistering and poor levelling are likely to occur. 9. Cutting structures coated with this paint generates fumes and dust; appropriate protection shall be provided. 10. When work is suspended, do not leave paint in the paint line, spray gun or spray equipment. Thoroughly flush all equipment with thinner. If the suspension is prolonged, it is recommended to mix a new batch of paint for application. 11. All equipment shall be cleaned with thinner immediately after use. Periodic flushing of spray equipment during daily work is a good practice. The flushing frequency depends on spray volume, temperature, spray time, including interruption time and other factors. 12. Residual paint and empty containers shall be disposed of in accordance with relevant local regulations.

Packaging

21 kg per unitBase 20 kgHardener 1 kg
16 L per unitBase 14.9LHardener 1.1L

Storage

Store sealed in a ventilated, cool and dry place, away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery