← Back to T&H brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Water-borne Epoxy Zinc-rich Primer XH4724

Quick Specs

Water-borne Epoxy Zinc-rich Primer XH4724 is a zinc-rich primer in the water-borne system. A water-borne two-component epoxy zinc-rich coating used as a primer in atmospheric environments; used with other coatings, it provides good anticorrosive performance. Parameters on this page: volume solids 54 ± 2%; dry film thickness 40/60/80 µm; theoretical spreading rate 6.8 m²/L.

Parameter source: T&H original technical data sheet (TDS) for Water-borne Epoxy Zinc-rich Primer XH4724; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids54 ± 2%
Dry Film Thickness40/60/80 µm
Theoretical Spreading Rate6.8 m2/L
VOC<130g/L
Density / Specific Gravity2.1 ± 0.2kg/L
Number of ComponentsTwo-component
Thinner0-5%
Mixing RatioBase : curing agent = 2.9:1 (by weight)
Colour / AppearanceZinc grey

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer, Water-borne, Epoxy

FAQ

How many components is water-borne epoxy zinc-rich primer?
Water-borne epoxy zinc-rich primer is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What is the mixing ratio of water-borne epoxy zinc-rich primer?
Mixing ratio of Water-borne Epoxy Zinc-rich Primer: base : hardener = 2.9:1 (by weight).
What dry film thickness is typically applied for water-borne epoxy zinc-rich primer?
Water-borne epoxy zinc-rich primer: typical dry film thickness 40/60/80 µm, subject to the coating system and design requirements.
What is the theoretical spreading rate of water-borne epoxy zinc-rich primer?
Theoretical spreading rate of Water-borne Epoxy Zinc-rich Primer: 6.8 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of water-borne epoxy zinc-rich primer?
Volume solids of Water-borne Epoxy Zinc-rich Primer: 54 ± 2%.
What is the VOC of water-borne epoxy zinc-rich primer?
The VOC of the water-borne epoxy zinc-rich primer is <130 g/L.
What is the gloss of water-borne epoxy zinc-rich primer?
The gloss of water-borne epoxy zinc-rich primer is matt.
Which thinner is used for water-borne epoxy zinc-rich primer?
Recommended thinner for water-borne epoxy zinc-rich primer: 0–5%.
Which standards apply to water-borne epoxy zinc-rich primer?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can water-borne epoxy zinc-rich primer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Thinner: deionised water

Product Description

A water-borne two-component epoxy zinc-rich coating, used as a primer in atmospheric environments; provides good anti-corrosion performance when used with other coatings.

Product Characteristics

Basic physical and chemical data

ColourZinc grey
GlossMatt
density2.1±0.2kg/L
Volume Solids54±2%
Volatile Organic Compounds<130g/L
Mixing ratioBase : curing agent = 2.9:1 (by weight)

Application parameters

Typical dry film thickness60µm
Recommended dry film thickness40–80 µm, depending on system requirements
Induction time (20 °C)No induction required

Application Methods

Thinner quantity (by volume)Airless spray 3–8%Air spray 8–15%Roller or brush 0–5%
Recommended nozzle size0.38~0.53mm1.2~3.0mmNone
Recommended spray pressure15~20MP0.3~0.4MPaNone
Application suitabilityRecommendedApplicableSuitable for small-area repair

Theoretical Spreading Rate

Dry film thickness (µm)406080
Wet film thickness (µm)74111148
Theoretical spreading rate (m²/L)13.596.8

Application data (typical dry film thickness 60 µm, RH = 55%):

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
20°C1h8h2h8h/
25°C1h6h2h6h/
30°C50min5h2h6h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

1. All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. 2. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair with this primer.

Precautions

1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as a mask and gloves; maintain adequate ventilation also during curing. 2. When mixing, first stir the base thoroughly, then add the hardener in the specified ratio and mix well; adjust the water quantity according to application needs and temperature, stir thoroughly, and do not add too much water at once, otherwise precipitation and lumping occur. Filter through a 120-mesh screen before use, and keep stirring during use. Note: never add water directly to the zinc dust component; water may be added only after the hardener has been thoroughly mixed in, otherwise the zinc dust separates out and the paint is wasted. 3. Excessive water thinning causes flocculation and separation, or reduced sag resistance. 4. This product is suitable only for blast-cleaned steel surfaces and approved epoxy zinc dust or inorganic zinc silicate coatings; it must not be applied over other coating types. Alkyd or alkyd-modified coatings must not be applied directly over this product. 5. During application and curing, the substrate temperature must be at least 3 °C above the dew point, moisture content <8%, ambient temperature 10–35 °C, and relative humidity not more than 80%. Indoor application is preferred to ensure application quality. 6. Cutting of structures coated with this product produces fume; take appropriate protection. 7. This product is not suitable for underwater use. 8. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with clean water. If the interruption is long, mix a fresh batch of paint for application. 9. Clean all equipment immediately after use with clean water. Note: the base, if not thoroughly emulsified with the hardener, forms flocs when water is added for cleaning, and may even block the gun. Flushing spray equipment periodically during daily work is good practice. Cleaning frequency depends on the volume sprayed, temperature, spraying time, including interruptions, and other factors. 10. Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.

Packaging*

19.5 kg per setBase 14.5 kgCuring agent 5 kg

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Ideal storage temperature 5–35 °C; protect from freezing at 0 °C and from high temperatures. Minimum 6 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. Avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery