Modified Phenolic Epoxy Static-dissipative Coating XH4226 is an epoxy coating. A two-component, high-build phenolic epoxy tank coating with static dissipation function; performance complies with the requirements of HG/T 4569 Static-dissipative Coatings for Petroleum and Petroleum Product Storage and Transport Equipment, for anti-corrosion protection of steel storage tanks, pipelines and other facilities and equipment. Parameters on this page: volume solids 55 ± 2%, DFT 50/100/125 µm, theoretical spreading rate 4.4 m²/L.
Parameter source: T&H original technical data sheet (TDS) "Modified Phenolic Epoxy Static-conductive Coating XH4226"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 55 ± 2% |
|---|---|
| Dry Film Thickness | 50/100/125 µm |
| Theoretical Spreading Rate | 4.4 m2/L |
| VOC | 420g/L |
| Density / Specific Gravity | 1.35 kg/L |
| Number of Components | Two-component |
| Flash Point | 25°C |
| Thinner | 0-15% |
| Mixing Ratio | Base : curing agent = 10:1 (by weight), 88:12 (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Two-component, high-build phenolic epoxy tank coating with static dissipation function; performance complies with the requirements of HG/T 4569 Static-dissipative Coatings for Petroleum and Petroleum Product Storage and Transport Equipment, for anti-corrosion protection of steel storage tanks, pipelines and other facilities and equipment.
| Colour | Light grey |
|---|---|
| Gloss | N/A |
| density | 1.35 kg/L |
| Volume Solids | 55±2% |
| Volatile Organic Compounds | 420g/L |
| Flash Point | 25°C |
| Mixing ratio | Base : curing agent = 10:1 (by weight), 88:12 (by volume) |
| Typical dry film thickness | 125µm×2 |
|---|---|
| Recommended dry film thickness | 200 µm (100 µm × 2)–300 µm (100 µm × 3), depending on system requirements |
| Induction time (20 °C) | 10~15min |
| Thinner quantity (by volume) | Airless spray 0–5% | Air spray 5–15% | Roller or brush 0–15% |
| Recommended nozzle size | 0.38~0.53mm | 2.0~3.0mm | / |
| Recommended spray pressure | 15~20MPa | 0.3~0.6MPa | / |
| Application suitability | Recommended | Applicable | |
| Dry film thickness (µm) | 50 | 100 | 125 |
| Wet film thickness (µm) | 91 | 174 | 139 |
| Theoretical spreading rate (m²/L) | 11 | 5.5 | 4.4 |
| Temperature | Surface Dry | Hard Dry | Pot Life | Recoat interval | |
| Minimum | Maximum* | ||||
| 5°C | 4h | 48h | 3 | 24h | / |
| 15°C | 2h | 24h | 3 | 24h | / |
| 25°C | 1h | 16h | 2 | 24h | / |
| 40°C | 40min | 4h | 1 | 12h | / |
*The maximum recoat interval depends on the exposure environment and the end use of the coating.
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair. If this coating is to be applied over an approved zinc dust primer old film, thoroughly remove any chalking or zinc salts before applying this product.
1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as a mask and gloves; maintain adequate ventilation also during curing. 2. Before mixing, stir Component A with a power tool, then add the curing agent and mix well; adjust the thinner quantity according to application needs and temperature, stir thoroughly and allow induction for 10–15 minutes before application. 3. Do not use paint beyond its pot life, otherwise the chemical resistance of the coating is severely affected. 4. This product is a primer/topcoat combined product, suitable only for blast-cleaned steel surfaces and approved zinc dust coatings; it must not be applied over other coating types, nor other coatings applied over it, otherwise static dissipation is affected. 5. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, with relative humidity not more than 85%. Temperature and relative humidity must be measured on the substrate near the work area. The paint temperature must not be below 10 °C. 6. The recommended dry film thickness per coat should not exceed 150 µm, otherwise retained solvent affects chemical resistance; multiple coats reduce coating defects and improve anti-corrosion performance. At ambient temperature, cure for 7–10 days before service; at low temperatures, extend curing (14–21 days) or use heating. Do not use this product below 5 °C. 7. If applying over a zinc dust primer old film, thoroughly remove any chalking or zinc salts, and confirm the surface resistance of the old coating meets requirements before applying this product. 8. Cutting of structures coated with this product produces fume; take appropriate protection. 9. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is long, mix a fresh batch of paint for application. 10. Clean all equipment immediately after use with thinner. Flushing spray equipment periodically during daily work is good practice. Cleaning frequency depends on the volume sprayed, temperature, spraying time, including interruptions, and other factors. 11. Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.
| 22 kg per unit | Component A (base) 20 kg | Component B (hardener) 2 kg |
| 16 L per unit | Component A (base) 14 L | Component B (Curing Agent) 2L |
Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.
1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.
The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.