Water-borne Inorganic Zinc-rich Primer XH4071-7003 belongs to zinc-rich primers, water-borne coating system. This product is a two-component environmentally friendly high-performance long-life anti-corrosion coating for steel structures, capable of ambient-temperature self-curing, composed of nano inorganic binder, ultrafine zinc powder and various additives. Parameters on this page: volume solids 67 ± 2%, dry film thickness 50/70/80 µm, theoretical spreading rate 8.4 m²/L.
Parameter source: T&H original technical data sheet (TDS) for Water-borne Inorganic Zinc-rich Primer XH4071-7003 (70%); spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 67 ± 2% |
|---|---|
| Dry Film Thickness | 50/70/80 µm |
| Theoretical Spreading Rate | 8.4 m2/L |
| VOC | ≤50g/L |
| Density / Specific Gravity | 2.60kg/L |
| Number of Components | Two-component |
| Thinner | 5% |
| Mixing Ratio | Base : curing agent = 26:10 (by weight) |
| Colour / Appearance | Zinc grey |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Thinner: water
The product is a two-component, green, environmentally friendly, high-performance, long-term anticorrosive coating for steel structures, composed of nano-inorganic binder, ultra-fine zinc dust and various additives, and self-curing at ambient temperature. It may be used as a heavy-duty anticorrosive primer for steel structures. Suitable for the corrosion protection of steel structures such as bridges, offshore platforms, hydraulic structures, chemical plants, machinery, building steelwork, thermal and nuclear power facilities and wind turbine towers.
| Colour | Zinc grey |
|---|---|
| Gloss | N/A |
| density | 2.60kg/L |
| Volume Solids | 67±2% |
| Volatile Organic Compounds | ≤50g/L |
| Flash Point | Non-flammable |
| Mixing ratio | Base : curing agent = 26:10 (by weight) |
| Typical dry film thickness | 50µm |
|---|---|
| Recommended dry film thickness | 50–100 µm, depending on system requirements |
| Thinner quantity (by volume) | Airless spray 5% | Air spray 5% | Roller or brush 5% |
| Recommended nozzle size | 0.43~0.64mm | 2.0~3.0mm | / |
| Recommended spray pressure | 15~20MPa | 0.3~0.6MPa | / |
| Application suitability | Recommended | Applicable | Suitable for small-area repair |
| Dry film thickness (µm) | 50 | 70 | 80 |
| Wet film thickness (µm) | 75 | 105 | 120 |
| Theoretical spreading rate (m²/L) | 13.4 | 9.6 | 8.4 |
Coating data (typical DFT 50 µm, relative humidity 65%):
| Temperature | Surface Dry | Hard Dry | Pot Life | Recoat interval | |
| Minimum | Maximum* | ||||
| 10°C | 60min | 4h | 7h | 48h | / |
| 20°C | 30min | 3h | 6h | 48h | / |
| 30°C | 20min | 2h | 5h | 24h | / |
| 40°C | 5min | 1h | 3h | 24h | / |
*The maximum recoat interval depends on the exposure environment and the end use of the coating.
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000
assessed and prepared in accordance with. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair with this primer. If the old film shows chalking or zinc salts, remove the zinc salts and contaminants before applying another primer, intermediate coat or topcoat.
| 1. | During application, ensure good ventilation and exhaust, keep away from ignition sources, and wear a mask, gloves and other protective equipment; during curing, adequate ventilation shall also be |
|---|
maintained.
| 2. | With the liquid component stirring, slowly add the zinc dust component, and mix thoroughly with a power tool; adjust the thinning according to application |
|---|
requirements and temperature, mix thoroughly, and strain through a 120-mesh sieve before use, stirring continuously during use. If the zinc dust is poured directly into the liquid component, or if thinner is added before mixing, the paint will be difficult to mix uniformly and defects such as gun blockage and uneven film are likely. Stir continuously during application to prevent zinc dust settling.
| 3. | The maximum permitted film thickness of this product is 120 µm; over-thick application may cause cracking. During application, attention shall be paid to |
|---|
the treatment of edges and corners of the workpiece and avoid over-thick application to prevent cracking.
| 4. | The product is suitable only for application over blast-cleaned steel surfaces and shall not be applied over other types of coatings. |
|---|
On substrates with an excessively low profile or on smooth surfaces, the coating cannot achieve good adhesion and may even detach.
| 5. | During application and curing, the substrate temperature shall be above 5 °C and at least 3 °C above the dew point, and the relative humidity shall not exceed 85%. |
|---|
Temperature and relative humidity shall be measured on the substrate close to the work area.
| 6. | Cutting structures coated with this coating produces fumes; appropriate protection shall be taken. |
|---|---|
| 7. | When applying other coatings over this product, sealing shall be carried out in advance; a dedicated sealer |
primer is recommended, or the subsequent epoxy coating may be thinned and mist-coated to seal the surface and avoid blistering. Alkyd, alkyd-modified and polyurethane coatings shall not be applied directly over this product.
| 8. | When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. |
|---|
If work is interrupted for too long, remix a fresh batch of paint before resuming.
| 9. | All equipment shall be cleaned with thinner immediately after use. Periodically flushing spray |
|---|
equipment during the daily work is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, spraying time and interruptions. 10. Remaining paint and empty cans shall be disposed of in accordance with relevant local regulations.
| 36 kg per unit | Base 26 kg | Curing Agent 10 kg |
The shelf life of this product is 12 months (at 23 °C ± 2 °C). Store in a dry, ventilated environment. Containers shall be kept sealed.
| 1. | Avoid inhaling spray mist and solvent, and avoid exposing skin and eyes or contact with wet paint. |
|---|---|
| 2. | All work related to the application and use of this product shall be carried out in accordance with the relevant national health, safety and |
environmental standards and regulations.
| 3. | If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; therefore |
|---|
suitable personal protective equipment and adequate local exhaust ventilation shall be used.
| 4. | If in doubt about the suitability of this product, consult the company. |
|---|
The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.