China-based coatings exporter — industrial & marine protective coatings from China's production bases

Epoxy Zinc-rich Primer XH4043B

Quick Specs

Epoxy Zinc-rich Primer XH4043B is a zinc-rich primer in the epoxy system. An epoxy zinc-rich coating, used as a high-performance anticorrosive primer for the corrosion protection of steel structures. Parameters on this page: volume solids 66 ± 2%, dry film thickness 60/80/90 µm, theoretical spreading rate 7.3 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Epoxy Zinc-rich Primer XH4043B"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids66 ± 2%
Dry Film Thickness60/80/90 µm
Theoretical Spreading Rate7.3 m2/L
VOC330g/L
Density / Specific Gravity1.9 kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner0-10%
Mixing RatioBase : curing agent = 10:1 (by weight), 81:19 (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer, Epoxy

FAQ

What is the mixing ratio of epoxy zinc-rich primer?
The mixing ratio of Epoxy Zinc-rich Primer is base : curing agent = 10:1 (by weight), 81:19 (by volume).
What dry film thickness is typically applied for epoxy zinc-rich primer?
Typical dry film thickness of the epoxy zinc-rich primer is 60/80/90 µm; the exact value depends on the coating system and design requirements.
What is the theoretical spreading rate of epoxy zinc-rich primer?
The theoretical spreading rate of Epoxy Zinc-rich Primer is 7.3 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of epoxy zinc-rich primer?
The volume solids of the epoxy zinc-rich primer is 66 ± 2%.
What is the VOC of epoxy zinc-rich primer?
The VOC of epoxy zinc-rich primer is 330 g/L.
What is the gloss of epoxy zinc-rich primer?
The gloss of epoxy zinc-rich primer is not applicable.
Which thinner is used for epoxy zinc-rich primer?
Recommended thinner for epoxy zinc-rich primer: 0–10%.
What is the flash point of epoxy zinc-rich primer?
The flash point of epoxy zinc-rich primer is 25 °C; storage, transport and application follow the product safety data sheet.
Which standards apply to epoxy zinc-rich primer?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can epoxy zinc-rich primer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

An epoxy zinc-rich coating, used as a high-performance anticorrosive primer for the corrosion protection of steel structures.

Product Characteristics

Basic physical and chemical data

ColourGrey
GlossN/A
density1.9 kg/L
Volume Solids66±2%
Volatile Organic Compounds330g/L
Flash Point25°C
Mixing ratioBase : curing agent = 10:1 (by weight), 81:19 (by volume)

Application parameters

Typical dry film thickness80µm
Recommended dry film thickness60–90 µm, depending on system requirements
Induction time (20 °C)10~15min

Application Methods

Thinner quantity (by volume)Airless spray 0–10%Air spray 10–20%Roller or brush 0–10%
Recommended nozzle size0.43~0.64mm2.0~3.0mmNone
Recommended spray pressure15~20MPa0.3~0.6MPaNone
Application suitabilityRecommendedApplicableSuitable for small-area repair

*Use a slow thinner in hot weather

Theoretical Spreading Rate

Dry film thickness (µm)608090
Wet film thickness (µm)91121136
Theoretical spreading rate (m²/L)118.37.3

Application data (typical dry film thickness 80 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C2h24hNo data24h/
15°C1.5h12h6h12h/
25°C1h8h4h8h/
40°C50min6h2h8h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free from contaminants. Before coating, all surfaces shall be assessed and treated in accordance with ISO 8504:2000. Blast to Sa 2½ with surface roughness 40–75 µm. Before rust removal, remove oil, grease and welding spatter, and grind welds and sharp corners. Film surfaces coated with this coating, where mechanically damaged and locally rusted, shall be locally blast cleaned to Sa 2½ or power-tool cleaned to St3 before local repair of the primer. If the old film surface chalks or produces zinc salts, the zinc salts and contaminants may be removed before applying the intermediate coat or topcoat.

Precautions

1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; adequate ventilation shall also be maintained during curing. 2. When mixing, first stir the base thoroughly, then add the curing agent per the ratio and mix evenly; adjust the thinner quantity according to application needs and temperature changes, stir well and allow induction; strain through a 120-mesh sieve before use and keep stirring during use. 3. Excessive thinner reduces sag resistance; never exceed the environmental regulation limits on thinner quantity. 4. This product is suitable only for application over blast-cleaned steel surfaces and approved epoxy zinc dust coatings and inorganic zinc silicate coatings; it must not be applied over other types of coating. Alkyd or alkyd-modified coatings must not be applied directly over this product's coating. 5. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, and relative humidity shall not exceed 85%. 6. Cutting structures coated with this coating produces fumes; take appropriate protection. 7. This product is not suitable for underwater use. 8. Avoid dry spray and over-thick application during application; applying the next coat over a dry-sprayed coating may cause pinholes, and over-thick application extends curing, handling and recoat times. The film thickness must match the surface roughness; low film thickness should not be applied on high-roughness surfaces, and over-thick application should be avoided. 9. When work is interrupted, do not leave coating in the paint line, spray gun or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, it is recommended to mix a fresh batch of paint for application. 10. Clean all equipment with thinner immediately after use. Periodically flushing spray equipment during the working day is good practice. The flushing frequency depends on the spray quantity, temperature and spray duration, including interruptions. 11. Dispose of leftover paint and empty cans in accordance with the relevant local regulations.

Packaging*

27.5 kg per unitBase 25 kgCuring agent 2.5 kg
14.5 L per unitBase 11.8 LCuring agent 2.7 L

*In some special cases, other packaging sizes may be used.

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery