China-based coatings exporter — industrial & marine protective coatings from China's production bases

Epoxy Topcoat XH4015

Quick Specs

Epoxy Topcoat XH4015 is an epoxy coating used as a topcoat. It can be used as a topcoat in non-sun-exposed environments, suitable for corrosion protection of facilities and equipment in harsh environments such as offshore installations, chemical plants, paper mills, smelters and bridges. Parameters on this page: volume solids 62 ± 2%, dry film thickness 50/80/100 µm, theoretical spreading rate 5.8 m²/L.

Parameter source: T&H original technical data sheet (TDS) for Epoxy Topcoat XH4015; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids62 ± 2%
Dry Film Thickness50/80/100 µm
Theoretical Spreading Rate5.8 m2/L
VOC370g/L
Density / Specific Gravity1.3 kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner0-15%
Mixing RatioBase : curing agent = 10:1 (by weight), 88:12 (by volume)

Browse Similar Models by CategoryThis model belongs to: Topcoat, Epoxy

FAQ

How many components is Epoxy Topcoat?
Epoxy Topcoat is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What is the mixing ratio of Epoxy Topcoat?
The mixing ratio of Epoxy Topcoat is base : curing agent = 10:1 (by weight), 88:12 (by volume).
What dry film thickness is typically applied for Epoxy Topcoat?
The typical dry film thickness of Epoxy Topcoat is 50/80/100 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Epoxy Topcoat?
The theoretical spreading rate of Epoxy Topcoat is 5.8 m²/L; the practical quantity is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Epoxy Topcoat?
The volume solids of Epoxy Topcoat is 62 ± 2%.
What is the VOC of Epoxy Topcoat?
The VOC of Epoxy Topcoat is 370 g/L.
What is the gloss of Epoxy Topcoat?
The gloss of Epoxy Topcoat is high gloss.
What thinner is used for Epoxy Topcoat?
Recommended thinner for Epoxy Topcoat: 0-15%.
What is the flash point of Epoxy Topcoat?
The flash point of Epoxy Topcoat is 25 °C. Storage, transport and application are subject to the product safety data sheet.
Which standards apply to Epoxy Topcoat?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Epoxy Topcoat be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

A two-component polyamide epoxy topcoat. It can be used as a topcoat in non-sun-exposed environments, suitable for corrosion protection of facilities and equipment in harsh environments such as offshore installations, chemical plants, paper mills, smelters and bridges.

Product Characteristics

Basic physical and chemical data

ColourAvailable in a wide range of colours
GlossHigh gloss
density1.3 kg/L
Volume Solids62±2%
Volatile Organic Compounds370g/L
Flash Point25°C
Mixing ratioBase : curing agent = 10:1 (by weight), 88:12 (by volume)

Application parameters

Typical dry film thickness60µm
Recommended dry film thickness50–100 µm, depending on system requirements
Induction time (20 °C)10-15min

Application Methods

Thinner quantity (by volume)Airless spray 0–10%Air spray 5–20%Roller or brush 0–15%
Recommended nozzle size0.38~0.53mm1.5~2.5mmNone
Recommended spray pressure15~20MPa0.3~0.6MPaNone
Application suitabilityRecommendedApplicableSuitable for small-area repair

*Use a slow thinner in hot weather

Theoretical Spreading Rate

Dry film thickness (µm)5080100
Wet film thickness (µm)86138173
Theoretical spreading rate (m²/L)11.67.35.8

Application data (typical dry film thickness 60 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C6h24h4h24h
15°C3h18h3h24h/
25°C1.5h12h2h12h
40°C1h6h1h8h

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated must be clean, dry and free from contamination. Before coating, all surfaces must be assessed and treated in accordance with ISO 8504:2000. On areas of the coated film that have suffered mechanical damage with local rusting, blast clean locally to Sa 2½ or prepare to St 3 by power tool, touch up with primer, and then apply the product. When applying over other old coatings, remove chalked film, zinc salts, grease and other contaminants by a suitable method. When applying over inorganic zinc silicate primer or thermally sprayed metal, an approved tie coat or intermediate coat must be used.

Precautions

1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; adequate ventilation should also be maintained during curing. 2. When mixing, stir the base thoroughly first, then add the curing agent in the specified ratio and mix thoroughly; adjust the amount of thinner according to application needs and temperature changes, and stir thoroughly and induce. 3. When applying over inorganic zinc silicate coating, seal it with an intermediate coat; the intermediate tie coat must be hard dry before applying this product, otherwise the effectiveness of sealing pinholes will be reduced. The product may also be thinned to a sufficiently low viscosity and used as a sealer. 4. Over-thinning reduces sag resistance and slows curing. 5. Over-application seriously affects drying, curing, recoating performance and handling time. Avoid applying excessively thick single coats on structural edges, corners, welds and other areas. 6. If the coating chalks after long-term exposure, wash with high-pressure water or abrade the surface before applying the subsequent coat. 7. Roller application cannot achieve high film thickness and a good continuous film in a single pass; multiple coats are required. 8. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, and the relative humidity must not exceed 85%. 9. Cutting structures coated with this product produces smoke and dust; take appropriate protection. 10. When work is interrupted, do not leave the coating in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, mix a fresh batch of paint for application. 11. All equipment should be cleaned with thinner immediately after use. Periodic flushing of spray equipment during the working day is good practice. The cleaning frequency depends on spray volume, temperature, spray time and factors including interruptions. 12. Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.

Packaging

19.8 kg per unitBase 18 kgCuring agent 1.8 kg
15 L per unitBase 13.2 LCuring agent 1.8 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery