← Back to T&H brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Epoxy Anti-corrosive Primer XH4010S

Quick Specs

Epoxy Anti-corrosive Primer XH4010S is an epoxy coating used as a primer. It is a general-purpose two-component high-build epoxy coating that can be used with a variety of coatings, suitable as an anti-corrosive primer for water-immersion coating systems, and has good adhesion to substrates such as aluminium alloy and aluminium-magnesium alloy. Parameters on this page: volume solids 60 ± 2%, dry film thickness 50/80/100 µm, theoretical spreading rate 5.9 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Epoxy Anti-corrosive Primer XH4010S"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids60 ± 2%
Dry Film Thickness50/80/100 µm
Theoretical Spreading Rate5.9 m2/L
VOC410g/L
Density / Specific Gravity1.45kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner5-15%
Mixing RatioBase : curing agent = 8:1 (by weight), 82:18 (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

FAQ

How many components does Epoxy Anti-corrosive Primer have?
Epoxy Anti-corrosive Primer is a two-component product; mix according to the mixing ratio in the 'Application Data' table on this page before use.
What is the mixing ratio of Epoxy Anti-corrosive Primer?
The mixing ratio of Epoxy Anti-corrosive Primer is base:curing agent = 8:1 (by weight) 82:18 (by volume).
What is the typical dry film thickness of Epoxy Anti-corrosive Primer?
The conventional dry film thickness of Epoxy Anti-corrosive Primer is 50/80/100 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Epoxy Anti-corrosive Primer?
The theoretical spreading rate of Epoxy Anti-corrosive Primer is 5.9 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Epoxy Anti-corrosive Primer?
The volume solids of Epoxy Anti-corrosive Primer is 60 ± 2%.
What is the VOC of Epoxy Anti-corrosive Primer?
The VOC of Epoxy Anti-corrosive Primer is 410 g/L.
What is the gloss of Epoxy Anti-corrosive Primer?
The gloss of Epoxy Anti-corrosive Primer is not applicable.
What thinner is used for Epoxy Anti-corrosive Primer?
Recommended thinner for Epoxy Anti-corrosive Primer: 5–15%.
What is the flash point of Epoxy Anti-corrosive Primer?
The flash point of Epoxy Anti-corrosive Primer is 25 °C; storage, transport and application shall be carried out in accordance with the product Safety Data Sheet.
Which standards apply to Epoxy Anti-corrosive Primer?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Epoxy Anti-corrosive Primer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

It is a general-purpose two-component high-build epoxy coating that can be used with a variety of coatings, suitable as an anti-corrosive primer for water-immersion coating systems, and has good adhesion to substrates such as aluminium alloy and aluminium-magnesium alloy.

Product Characteristics

Basic physical and chemical data

ColourGrey
GlossN/A
density1.45kg/L
Volume Solids60±2%
Volatile Organic Compounds410g/L
Flash Point25°C
Mixing ratioBase : curing agent = 8:1 (by weight), 82:18 (by volume)

Application parameters

Typical dry film thickness80µm
Recommended dry film thickness50–100 µm, depending on system requirements
Induction time (20 °C)10~15min

Application Methods

Thinner quantity (by volume)Airless spray 0–15%Air spray 5–20%Roller or brush 5–15%
Recommended nozzle size0.43~0.64mm1.5~2.5mm/
Recommended spray pressure15~20MPa0.3~0.6MPa/
Application suitabilityRecommendedApplicableFor small-area repair only

*Use a slow thinner in hot weather

Theoretical Spreading Rate

Dry film thickness (µm)5080100
Wet film thickness (µm)85136170
Theoretical spreading rate (m²/L)11.87.45.9

Application data (typical dry film thickness 80 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C90min24h6h48h/
15°C50min16h5h24h/
25°C30min8h4h12h/
40°C20min6h2h8h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair. If this coating is to be applied over an approved zinc dust primer old film, thoroughly remove any chalking or zinc salts from the zinc dust coating before applying this product. For concrete protection, the concrete must be cured, with moisture content and surface condition meeting the relevant requirements.

Precautions

1. During application, ensure good ventilation and exhaust, keep away from ignition sources, and wear a mask, gloves and other protective equipment; adequate ventilation shall also be maintained during curing. 2. Before mixing the two components, stir the base thoroughly with a power tool, then add the curing agent and mix uniformly; adjust the thinner amount according to application requirements and temperature changes, mix thoroughly, and allow an induction time of 10–15 min before application. 3. The product may be used as a primer for galvanized steel or stainless steel; abrading or light blasting of these substrates gives better adhesion. 4. When used as a protective primer on concrete, it is normally used with a dedicated concrete sealer. If applied to concrete without a sealer, thin the product to a sufficiently low viscosity (20–30% thinner) and seal the concrete; ensure the sealer is hard dry before overcoating. 5. When used as a tie-coat over inorganic zinc silicate primers, add 20–30% thinner to reduce the viscosity, and ensure the tie-coat is hard dry before applying the next coat, otherwise the effectiveness of sealing pinholes will be reduced. If the product is applied over an old zinc dust primer film, chalk or zinc salts on the zinc dust coating shall be removed thoroughly. 6. The recommended film thickness per coat shall not exceed 120 µm, otherwise the surface smoothness rises and affects overcoating. If the coating chalks after long-term exposure, wash with high-pressure water or abrade the surface before applying the next coat. 7. During application and curing, the substrate temperature shall be above 5 °C and at least 3 °C above the dew point, and the relative humidity shall not exceed 85%. Temperature and relative humidity shall be measured on the substrate close to the work area. 8. Cutting structures coated with this coating produces fumes; appropriate protection shall be taken. 9. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If work is interrupted for too long, remix a fresh batch of paint before resuming. 10. All equipment shall be cleaned with thinner immediately after use. Periodically flushing spray equipment during the daily work is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, spraying time and interruptions. 11. Remaining paint and empty cans shall be disposed of in accordance with relevant local regulations.

Packaging

22.5 kg per unitBase 20 kgCuring agent 2.5 kg
15 L per unitBase 12.3 LCuring agent 2.7 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery