China-based coatings exporter — industrial & marine protective coatings from China's production bases

Cold-spray Zinc Coating XH4009

Quick Specs

Cold Spray Zinc Coating XH4009 is a cold spray zinc coating. Used for cathodic protection of offshore and onshore steel structures; can be used alone or with various other anti-corrosion coatings, suitable for long-term anti-corrosion of new or old large steel structures in marine and industrial atmospheres. Parameters on this page: volume solids 48 ± 2%, dry film thickness 40/70/100 µm, theoretical spreading rate 4.8 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Cold-spray Zinc Coating XH4009"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids48 ± 2%
Dry Film Thickness40/70/100 µm
Theoretical Spreading Rate4.8 m2/L
VOC460g/L
Density / Specific Gravity3.15 ± 0.2 kg/L
Number of ComponentsOne-component
Thinner0-5%
Colour / AppearanceGrey-white
GlossN/A

Browse Similar Models by CategoryThis model belongs to: Cold Galvanizing

FAQ

How many components does Cold Spray Zinc Coating have?
Cold Spray Zinc Coating is a single-component product; stir thoroughly after opening the can and apply. No on-site mixing is required.
What is the typical dry film thickness for Cold Spray Zinc Coating?
The typical dry film thickness of Cold Spray Zinc Coating is 40/70/100 µm; the exact value depends on the coating system and design requirements.
What is the theoretical spreading rate of Cold Spray Zinc Coating?
The theoretical spreading rate of Cold Spray Zinc Coating is 4.8 m²/L; actual consumption depends on substrate roughness, application losses and colour opacity.
What is the volume solids of Cold Spray Zinc Coating?
The volume solids of Cold Spray Zinc Coating is 48 ± 2%.
What is the VOC of Cold Spray Zinc Coating?
The VOC of Cold Spray Zinc Coating is 460 g/L.
What is the gloss of Cold Spray Zinc Coating?
The gloss of Cold Spray Zinc Coating is not applicable.
What thinner is used with Cold Spray Zinc Coating?
Recommended thinner for Cold Spray Zinc Coating: 0–5%.
Which standards apply to Cold Spray Zinc Coating?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Cold Spray Zinc Coating be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Curing agent: none

Product Description

A single-component galvanizing system composed of high-purity metallic zinc powder, volatile solvents and organic resin. The zinc content in the dry film is as high as 95%. Used for cathodic protection of offshore and onshore steel structures; can be used alone or with various other anti-corrosion coatings, suitable for long-term anti-corrosion of new or old large steel structures in marine and industrial atmospheres.

Product Characteristics

Basic physical and chemical data

ColourGrey-white
GlossN/A
density3.15±0.2 kg/L
Volume Solids48±2%
Volatile Organic Compounds460g/L

Application parameters

Typical dry film thickness40µm
Recommended dry film thickness40–100 µm, depending on system requirements

Application Methods

Thinner quantity (by volume)Airless spray 0–10%Air spray 10–20%Roller or brush 0–5%
Recommended nozzle size0.4~0.8mm2.0~3.0mm/
Recommended spray pressure10~30MPa0.3~0.6MPa/
Application suitabilityApplicable

* XH4009 requires special thinner XH9501 and must not be mixed with others

Theoretical Spreading Rate

Dry film thickness (µm)4070100
Wet film thickness (µm)83146208
Theoretical spreading rate (m²/L)126.94.8

Application data (typical dry film thickness 40 µm)

TemperatureSurface DrySemi-hard dryPot LifeRecoat interval
MinimumMaximum*
5°C1h4h/4h1mo.
20°C20min2h/2h1mo.
25°C20min1h/1.5h1mo.
30°C20min1h/1h1mo.

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free of contaminants. Before coating, all surfaces shall be assessed and treated in accordance with ISO 8504:2000. Blast clean to Sa 2½, surface roughness 50–75 µm. For areas with less severe corrosion, hand or power tool grinding to St 3 is acceptable, with light rust allowed to remain. Before rust removal, oil and weld spatter shall be removed and welds and sharp corners ground. If the film coated with this paint is mechanically damaged and localized rusting occurs, the area shall be spot blast cleaned to Sa 2½ or power tool cleaned to St 3 before localized repair. If this coating is to be applied over approved old hot-dip galvanized, electro-galvanized and old zinc-plus-coating surfaces, the chalking or zinc salts on the surface must be thoroughly removed before applying this product.

Precautions

1. During application, ensure adequate ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; maintain adequate ventilation also during curing. 2. Adjust the thinner amount according to application needs and temperature changes, stir thoroughly, then filter through a 120-mesh copper wire screen before application. 4. During application and curing, the substrate temperature must be above the dew point by 3 °C, and the surface temperature must not exceed 60 °C. The ambient temperature should be controlled at -5–35 °C, with relative humidity not exceeding 90%; indoor application is preferred when possible to better ensure appearance quality. 5. Subsequent compatible coat: a two-component epoxy MIO paint is recommended. When applying, dilute the epoxy MIO paint by half and mist spray one coat of 20–40 µm as a tie coat before normal application of the epoxy MIO paint. It must not be used directly with oil-based alkyd or polyester paints. 6. Cutting of structures coated with this paint will generate smoke and dust; take appropriate protection. 7. When work is interrupted, do not leave paint in the hose, spray gun or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, it is recommended to remix a new batch of paint for application. 8. All equipment shall be cleaned with thinner immediately after use. Flushing the spray equipment periodically during daily work is good practice. The cleaning frequency depends on spray volume, temperature, spraying time and interruptions. 9. Leftover paint and empty cans shall be disposed of according to local regulations.

Packaging

9.5L

Storage

Store sealed in a ventilated, cool and dry place, away from sources of ignition, for at least 18 months

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery