Quick Specs

Inorganic Zinc-rich Primer XH4006 is a zinc-rich primer. Used for protection of steel facilities and equipment, high-temperature pipelines, bridges and storage tanks in severely corrosive atmospheric environments. Parameters on this page: volume solids 65 ± 2%; dry film thickness 60/80/100 µm; theoretical spreading rate 6.5 m²/L.

Parameter source: T&H original technical data sheet (TDS) for Inorganic Zinc-rich Primer XH4006; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids65 ± 2%
Dry Film Thickness60/80/100 µm
Theoretical Spreading Rate6.5 m2/L
VOC410g/L
Density / Specific Gravity2.8 kg/L
Number of ComponentsTwo-component
Flash Point17°C
Thinner5-15%
Mixing RatioBase : curing agent = 4.3:1 (by weight), 45:55 (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer

FAQ

How many components is inorganic zinc-rich primer?
Inorganic zinc-rich primer is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What is the mixing ratio of inorganic zinc-rich primer?
Mixing ratio of Inorganic Zinc-rich Primer: base : hardener = 4.3:1 (by weight), 45:55 (by volume).
What dry film thickness is typically applied for inorganic zinc-rich primer?
Inorganic zinc-rich primer: typical dry film thickness 60/80/100 µm, subject to the coating system and design requirements.
What is the theoretical spreading rate of inorganic zinc-rich primer?
The theoretical spreading rate of the inorganic zinc-rich primer is 6.5 m²/L; actual consumption depends on substrate roughness, application loss and colour hiding power.
What is the volume solids of inorganic zinc-rich primer?
The volume solids of the inorganic zinc-rich primer is 65 ± 2%.
What is the VOC of inorganic zinc-rich primer?
The VOC of the inorganic zinc-rich primer is 410 g/L.
What is the gloss of inorganic zinc-rich primer?
The gloss of inorganic zinc-rich primer is not applicable.
Which thinner is used for inorganic zinc-rich primer?
Recommended thinner for inorganic zinc-rich primer: 5–15%.
What is the flash point of inorganic zinc-rich primer?
The flash point of inorganic zinc-rich primer is 17 °C; storage, transport and application follow the product safety data sheet.
Which standards apply to inorganic zinc-rich primer?
As recorded in the technical data on this page: HG/T3668 (see the application instructions on this page); before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can inorganic zinc-rich primer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

A two-component solvent-borne inorganic zinc silicate coating whose performance and composition comply with HG/T 3668. Used for protection of steel facilities and equipment, high-temperature pipelines, bridges and storage tanks in severely corrosive atmospheric environments.

Product Characteristics

Basic physical and chemical data

ColourZinc grey
GlossN/A
density2.8 kg/L
Volume Solids65±2%
Volatile Organic Compounds410g/L
Flash Point17°C
Mixing ratioBase : curing agent = 4.3:1 (by weight), 45:55 (by volume)

Application parameters

Typical dry film thickness60µm
Recommended dry film thickness50–100 µm, depending on system requirements
Induction time (20 °C)No induction required

Application Methods

Thinner quantity (by volume)Airless spray 5–20%Air spray 5–20%Roller or brush 5–15%
Recommended nozzle size0.43~0.64mm2.0~3.0mm/
Recommended spray pressure15~20MPa0.3~0.6MPa/
Application suitabilityRecommendedApplicableSuitable for small-area repair

*For low-temperature application and where fast hard drying is required, use a fast thinner.

Theoretical Spreading Rate

Dry film thickness (µm)6080100
Wet film thickness (µm)100130160
Theoretical spreading rate (m²/L)10.88.26.5

Application data (typical dry film thickness 60 µm, 65% relative humidity):

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C60min12h8h48h/
15°C60min6h48h/
25°C30min4h5h24h/
40°C30min2h3h24h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free from contamination. Before application, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Blast clean to Sa2½ with a surface profile of 40–75 µm. Before derusting, remove all oil, grease and weld spatter, and grind welds and sharp edges. Where the coating film has suffered mechanical damage with localised rusting, spot blast to Sa2½ or power-tool clean to St3 before local repair of the primer. If the old film shows chalking or zinc salts, remove the zinc salts and contamination before applying other primers, intermediate coats or topcoats.

Precautions

1. During application, ensure ventilation and exhaust, keep away from ignition sources, and wear protective equipment such as masks and gloves; maintain adequate ventilation during curing. 2. Add the zinc powder component slowly while stirring the liquid component, and mix thoroughly with a power tool; adjust the thinner quantity according to application needs and temperature. Strain through a 120-mesh screen before use and keep stirring during use. If the zinc powder is poured directly into the liquid, or the thinner is added before mixing, the paint will be hard to mix evenly and defects such as gun blockage and uneven film may result. 3. The maximum dry film thickness allowed is 120 µm; over-thick application may crack. Pay attention to edges/corners and over-thickness to avoid cracking. 4. This product is suitable only for blast-cleaned steel surfaces and inorganic zinc silicate coatings, and must not be applied over other coating types. On substrates with too-low roughness or smooth surfaces, the coating cannot achieve good adhesion and may even detach. 5. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, and relative humidity must not exceed 85%. Temperature and relative humidity must be measured on the substrate near the working point. Keep the working environment well ventilated with relative humidity not below 60%. If the humidity is below 60% during application, wet the surface by spraying water, and assess cure per ASTM D4752 to at least rating 4 before recoating. 6. When the product is used alone in oil-, solvent- or chemical-resistant systems, the film thickness should not exceed 90 µm. The permissible pH range of the medium is 6–9. Assess cure per ASTM D4752 to rating 5. 7. Cutting structures coated with this product produces fumes and dust; take appropriate protection. 8. When overcoating this product, seal first, preferably with a dedicated sealer primer, or thin the subsequent epoxy coating and mist-coat it to seal, to avoid bubbling. Alkyd, alkyd-modified and polyurethane coatings must not be applied directly over this product. 9. During work breaks, do not leave paint in the hose, spray gun or spray equipment. Flush all equipment thoroughly with thinner. If the break is too long, mix a fresh batch of paint for application. 10. Clean all equipment with thinner immediately after use. Flushing spray equipment regularly during work is good practice. Cleaning frequency depends on spray volume, temperature and spraying time including interruptions. 11. Dispose of leftover paint and empty cans in accordance with local regulations.

Packaging

25.4 kg per unitBase 20.6 kgCuring agent 4.8 kg
9.1 L per setBase 4.1 LCuring agent 5 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 9 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery