Fluorocarbon Topcoat XH1303

Quick Specs

Fluorocarbon Topcoat XH1303 is a fluorocarbon coating used as a topcoat. With superb weatherability, as a highly protective topcoat in severe atmospheric environments, it can greatly extend the protective life of the coating system. Parameters on this page: volume solids 49 ± 2%, dry film thickness 40/60/80 µm, theoretical spreading rate 6 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Fluorocarbon Topcoat XH1303"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids49 ± 2%
Dry Film Thickness40/60/80 µm
Theoretical Spreading Rate6 m2/L
VOC470g/L
Density / Specific Gravity1.35 kg/L
Number of ComponentsTwo-component
Flash Point27°C
Thinner0-20%
Mixing RatioBase : curing agent = 10:1 (by weight), 88:12 (by volume)

Browse Similar Models by CategoryThis model belongs to: Topcoat, Fluorocarbon

FAQ

How many components does the fluorocarbon topcoat have?
The fluorocarbon topcoat is a two-component product; mix according to the mixing ratio in the 'Coating Data' table on this page.
What is the mixing ratio of the fluorocarbon topcoat?
The mixing ratio of Fluorocarbon Topcoat is base : curing agent = 10:1 (by weight), 88:12 (by volume).
What is the typical dry film thickness of the fluorocarbon topcoat?
Typical dry film thickness of the fluorocarbon topcoat is 40/60/80 µm; the exact value depends on the coating system and design requirements.
What is the theoretical spreading rate of the fluorocarbon topcoat?
The theoretical spreading rate of Fluorocarbon Topcoat is 6 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of the fluorocarbon topcoat?
The volume solids of Fluorocarbon Topcoat is 49 ± 2%.
What is the VOC of the fluorocarbon topcoat?
The VOC of Fluorocarbon Topcoat is 470 g/L.
What is the gloss of the fluorocarbon topcoat?
The gloss of the fluorocarbon topcoat is semi-gloss.
What thinner is used for the fluorocarbon topcoat?
Recommended thinner for the fluorocarbon topcoat: 0–20%.
What is the flash point of the fluorocarbon topcoat?
The flash point of the fluorocarbon topcoat is 27 °C; storage, transport and application shall follow the product safety data sheet.
Which standards apply to the fluorocarbon topcoat?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can the fluorocarbon topcoat be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

A high-performance two-component fluorocarbon coating. With excellent weathering resistance, as a highly protective topcoat in severe atmospheric environments, it can significantly extend the service life of the coating system.

Product Characteristics

Basic physical and chemical data

ColourAvailable in various colours
GlossSemi-gloss
density1.35 kg/L
Matching curing agentXH7202A
Volume Solids49±2%
Volatile Organic Compounds470g/L
Flash Point27°C
Mixing ratioBase : curing agent = 10:1 (by weight), 88:12 (by volume)

Application parameters

Typical dry film thickness60µm
Recommended dry film thickness40–80 µm, depending on system requirements
Induction time (20 °C)10-15min

Application Methods

Thinner quantity (by volume)Airless spray 5–20%Air spray 15–30%Roller or brush 0–20%
Recommended nozzle size0.38~0.53mm1.5~2.5mmNone
Recommended spray pressure15~20MPa0.3~0.6MPaNone
Application suitabilityRecommendedApplicableSuitable for small-area repair

*Select a suitable thinner according to the season and temperature

Theoretical Spreading Rate

Dry film thickness (µm)406080
Wet film thickness (µm)82122163
Theoretical spreading rate (m²/L)1286

Application data (typical dry film thickness 60 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C2h24h4h24h
15°C90min12h2.5h12h/
25°C60min6h2h6h
40°C30min3h45min4h

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free from contamination. Before application, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. The product shall be applied over the recommended anticorrosive primer or intermediate coat within the specified overcoating interval; the primer or intermediate coat surface shall be dry and free from contamination. When applied over existing coatings, chalk, grease and other contaminants shall be removed by appropriate methods. In cracked or damaged areas, the substrate shall be prepared to Sa2½ or St3 and the primer repaired before applying this product.

Precautions

1. During application, ensure good ventilation and exhaust, keep away from ignition sources, and wear a mask, gloves and other protective equipment; adequate ventilation shall also be maintained during curing. 2. When mixing, first stir the base thoroughly, then add the curing agent in the specified ratio and mix uniformly; adjust the thinner amount according to application requirements and temperature changes, and mix and induce thoroughly. 3. Excessive thinning will reduce sag resistance and slow curing. 4. Over-thick application will seriously affect drying, curing, overcoating performance and handling time. 5. After long-term exposure, before overcoating, ensure the old film surface is free from contamination and abrade the surface before applying the next coat. 6. With brush or roller application, high film thickness and a good continuous film cannot be obtained in a single pass; multiple coats are required. 7. When the product is prepared with bright chrome-free red or yellow pigments and applied over dark primers, multiple coats are required for good hiding; therefore a light-coloured primer or intermediate coat is recommended with these colours. 8. During application and curing, the substrate temperature shall be above 5 °C and at least 3 °C above the dew point, and the relative humidity shall not exceed 85%. 9. Cutting structures coated with this coating produces fumes; appropriate protection shall be taken. 10. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If work is interrupted for too long, remix a fresh batch of paint before resuming. 11. All equipment shall be cleaned with thinner immediately after use. Periodically flushing spray equipment during the daily work is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, spraying time and interruptions. 12. Remaining paint and empty cans shall be disposed of in accordance with relevant local regulations.

Packaging

22 kg per unitBase 20 kgCuring agent 2 kg
16 L per unitBase 14 LCuring agent 2 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information in this data sheet is based on laboratory test results that we believe to be accurate, and is provided as application guidance only. All recommendations and advice on the use of T&H products, whether in technical documents, special consultations or otherwise, are based on information that we believe to be reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience; it is ultimately the end user who decides whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of the company's products or from reliance on this data sheet (unless otherwise agreed in writing). The data in this data sheet will be revised as necessary based on practical experience and continuous product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery