NavalGuard 5910 Acrylic Boottop Coating

Quick Specs

Water Shield Acrylic Waterline Coating NavalGuard 5910 is an acrylic coating. An acrylic topcoat composed of acrylic resin, colouring pigments, additives, plasticiser and organic solvents, used in systems for moderate to severe corrosion environments. Parameters on this page: volume solids 46 ± 2%, dry film thickness 50/60/80 µm, theoretical spreading rate 5.7 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "NavalGuard 5910 Acrylic Boottop Coating"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids46 ± 2%
Dry Film Thickness50/60/80 µm
Theoretical Spreading Rate5.7 m2/L
VOC490g/L
Density / Specific Gravity1.35kg/L
Number of ComponentsOne-component
Flash Point25°C
Thinner5-15%
Colour / AppearanceVarious colours

Browse Similar Models by CategoryThis model belongs to: Acrylic

FAQ

What dry film thickness is normally applied for Water Shield Acrylic Waterline Coating?
Water Shield Acrylic Waterline Coating is normally applied at 50/60/80 µm dry film thickness; the exact value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Water Shield Acrylic Waterline Coating?
The theoretical spreading rate of Water Shield Acrylic Waterline Coating is 5.7 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Water Shield Acrylic Waterline Coating?
The volume solids of Water Shield Acrylic Waterline Coating is 46 ± 2%.
What is the VOC of Water Shield Acrylic Waterline Coating?
The VOC of Water Shield Acrylic Waterline Coating is 490 g/L.
What is the gloss of Water Shield Acrylic Waterline Coating?
The gloss of Water Shield Acrylic Waterline Coating is semi-gloss.
Which thinner is used for Water Shield Acrylic Waterline Coating?
The recommended thinner for Water Shield Acrylic Waterline Coating: 5–15%.
What is the flash point of Water Shield Acrylic Waterline Coating?
The flash point of Water Shield Acrylic Waterline Coating is 25 °C. Handle, store and apply in accordance with the product safety data sheet.
Which standards apply to Water Shield Acrylic Waterline Coating?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Water Shield Acrylic Waterline Coating be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Curing agent: none

Product Description

An acrylic topcoat composed of acrylic resin, colouring pigments, additives, plasticiser and organic solvents, used in systems for moderate to severe corrosion environments.

Product Characteristics

Basic physical and chemical data

ColourVarious colours
GlossSemi-gloss
density1.35kg/L
Volume Solids46±2%
Volatile Organic Compounds490g/L
Flash Point25°C

Application parameters

Typical dry film thickness60µm
Recommended dry film thickness50–100 µm, depending on system requirements

Application Methods

Thinner quantity (by volume)Airless spray 5–15%Air spray 10–30%Roller or brush 5–15%
Recommended nozzle size0.43~0.64mm1.5~2.5mm/
Recommended spray pressure15~20MPa0.3~0.6MPa/
Application suitabilityRecommended

Theoretical Spreading Rate

Dry film thickness (µm)506080
Wet film thickness (µm)109130174
Theoretical spreading rate (m²/L)9.27.75.7

Application data (typical dry film thickness 40 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C4h48h/48h/
15°C2h36h/36h/
25°C1h24h/24h/
40°C0.5h16h/16h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated shall be clean, dry and free from contaminants. Before coating, all surfaces shall be assessed and treated in accordance with ISO 8504:2000. Film surfaces coated with this coating, where mechanically damaged and locally rusted, shall be ground, filled or otherwise suitably treated. Surface quality may be reduced to Sa 2, but no loose powdery deposits shall be produced.

Precautions

1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; adequate ventilation shall also be maintained during curing. 2. Adjust the thinner quantity according to temperature changes, mix thoroughly, and filter through a 120-mesh copper sieve before use. Unused paint shall be sealed if not used for a long time, otherwise skinning may occur. If skinning occurs, filter out the skin before use. 3. The recommended thickness of one coat of this product shall not exceed 50 µm. Over-thick single coats affect curing and recoating performance and tend to cause defects such as lifting and wrinkling on recoating. This coating must not be applied over coatings containing zinc dust, nor over hot-dip galvanized, thermally sprayed zinc or aluminium surfaces, otherwise adhesion will be lost. 4. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, and relative humidity shall not exceed 85%. Temperature and relative humidity must be measured on the substrate near the working area. 5. Cutting structures coated with this coating produces fumes; take appropriate protection. 6. When work is interrupted, do not leave coating in the paint line, spray gun or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, it is recommended to mix a fresh batch of paint for application. 7. Clean all equipment with thinner immediately after use. Periodically flushing spray equipment during the working day is good practice. The flushing frequency depends on the spray quantity, temperature and spray duration, including interruptions. 8. Dispose of leftover paint and empty cans in accordance with the relevant local regulations.

Packaging

20kg/14.8L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery