NavalGuard 5406 Water-borne Alkyd Topcoat is an alkyd coating for use as a topcoat. For applications requiring an enhanced appearance, such as dry interior areas or low-corrosivity exterior environments. Parameters on this page: volume solids 48 ± 2%, dry film thickness 30/40/50 µm, theoretical spreading rate 9.5 m²/L.
Parameter source: T&H original technical data sheet (TDS) for Water Shield Alkyd Topcoat NavalGuard5406; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 48 ± 2% |
|---|---|
| Dry Film Thickness | 30/40/50 µm |
| Theoretical Spreading Rate | 9.5 m2/L |
| VOC | 470g/L |
| Density / Specific Gravity | 1.5 kg/L |
| Number of Components | One-component |
| Flash Point | 25°C |
| Thinner | 5-15% |
| Colour / Appearance | Various colours |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Curing agent: none
A single-component, fast-drying alkyd topcoat designed as a one-coat finish providing both corrosion protection and decorative appearance. For applications where appearance is important, such as dry interior areas or low-corrosivity exterior environments.
| Colour | Various colours |
|---|---|
| Gloss | Semi-gloss |
| density | 1.5 kg/L |
| Volume Solids | 48±2% |
| Volatile Organic Compounds | 470g/L |
| Flash Point | 25°C |
| Typical dry film thickness | 40µm |
|---|---|
| Recommended dry film thickness | 30–50 µm, depending on system requirements |
| Thinner quantity (by volume) | Airless spray 5–15% | Air spray 10–30% | Roller or brush 5–15% |
| Recommended nozzle size | 0.43~0.64mm | 1.5~2.5mm | / |
| Recommended spray pressure | 15~20MPa | 0.3~0.6MPa | / |
| Application suitability | Recommended | ||
| Dry film thickness (µm) | 30 | 40 | 50 |
| Wet film thickness (µm) | 63 | 83 | 104 |
| Theoretical spreading rate (m²/L) | 15.9 | 11.9 | 9.5 |
| Temperature | Surface Dry | Hard Dry | Pot Life | Recoat interval | |
| Minimum | Maximum* | ||||
| 5°C | 4h | 48h | / | 48h | / |
| 15°C | 3h | 36h | / | 36h | / |
| 25°C | 2h | 24h | / | 24h | / |
| 40°C | 1h | 16h | / | 16h | / |
*The maximum recoat interval depends on the exposure environment and the end use of the coating.
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Areas of the coating damaged mechanically and showing localised rust must be ground, filled or treated by a suitable method. The surface quality may drop to Sa 2, but no loose powdery deposits must be present.
1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as a mask and gloves; maintain adequate ventilation also during curing. 2. Adjust the thinner quantity according to temperature, mix thoroughly, and filter through a 120-mesh copper screen before use. Seal unused paint if not used for a long time, otherwise skinning occurs; if skinning occurs, remove the skin before use. 3. The recommended dry film thickness per coat should not exceed 50 µm. Over-application in one coat affects curing and recoatability, and may cause lifting and wrinkling on recoating. This coating must not be applied over zinc-containing coatings, nor over hot-dip galvanised, hot-sprayed zinc or aluminium surfaces, otherwise adhesion is lost. 4. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, with relative humidity not more than 85%. Temperature and relative humidity must be measured on the substrate near the work area. 5. Cutting of structures coated with this product produces fume; take appropriate protection. 6. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. 7. Clean all equipment immediately after use with thinner. Flushing spray equipment periodically during daily work is good practice. Cleaning frequency depends on the volume sprayed, temperature, spraying time, including interruptions, and other factors. 8. Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.
22.5kg/15L
Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.
1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.
The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.