← Back to T&H brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

NavalGuard 4227 Pure Epoxy Coating (potable water)

Quick Specs

Water Shield Pure Epoxy Coating NavalGuard4227 belongs to potable water tank coatings, epoxy coating system. A high-solids, high-build epoxy coating for corrosion protection of the internal walls of tanks and pipes for industrial wastewater, fire water, circulating water. Parameters on this page: volume solids 81 ± 2%, DFT 80/150/200 µm, theoretical spreading rate 4 m²/L.

Parameter source: T&H original technical data sheet (TDS) "NavalGuard 4227 Pure Epoxy Coating (potable water)"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids81 ± 2%
Dry Film Thickness80/150/200 µm
Theoretical Spreading Rate4 m2/L
VOC190g/L
Density / Specific Gravity1.5kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner0-15%
Mixing RatioBase : curing agent = 6:1 (by weight), 79:21 (by volume)

Browse Similar Models by CategoryThis model belongs to: Potable Water Tank, Epoxy

FAQ

What is the mixing ratio of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The mixing ratio of Water Shield Pure Epoxy Coating (Potable Water Coating) is Base : Curing agent = 6:1 (by weight), 79:21 (by volume).
What DFT is normally applied for Water Shield Pure Epoxy Coating (Potable Water Coating)?
Typical DFT of Water Shield Pure Epoxy Coating (Potable Water Coating) is 80/150/200 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The theoretical spreading rate of Water Shield Pure Epoxy Coating (Potable Water Coating) is 4 m²/L; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The volume solids of Water Shield Pure Epoxy Coating (Potable Water Coating) is 81 ± 2%.
What is the VOC of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The VOC of Water Shield Pure Epoxy Coating (Potable Water Coating) is 190g/L.
What is the gloss of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The gloss of Water Shield Pure Epoxy Coating (Potable Water Coating) is not applicable.
Which thinner is used for Water Shield Pure Epoxy Coating (Potable Water Coating)?
Recommended thinner for Water Shield Pure Epoxy Coating (Potable Water Coating): 0–15%.
What is the flash point of Water Shield Pure Epoxy Coating (Potable Water Coating)?
The flash point of Water Shield Pure Epoxy Coating (Potable Water Coating) is 25°C; storage, transport and application shall follow the product safety data sheet.
Which standards apply to Water Shield Pure Epoxy Coating (Potable Water Coating)?
As recorded in the technical data on this page: meets the GB/T 5749-2006 hygiene standard; before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Water Shield Pure Epoxy Coating (Potable Water Coating) be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

A high-solids, high-build epoxy coating for corrosion protection of the internal walls of tanks and pipes for industrial wastewater, fire water, circulating water. Complies with the GB/T 5749-2006 hygiene standard.

Product Characteristics

Basic physical and chemical data

ColourWhite, light grey, light pink
GlossN/A
density1.5kg/L
Volume Solids81±2%
Volatile Organic Compounds190g/L
Flash Point25°C
Mixing ratioBase : curing agent = 6:1 (by weight), 79:21 (by volume)

Application parameters

Typical dry film thickness100µm
Recommended dry film thickness100–450 µm, depending on system requirements
Induction time (20 °C)10~15min

Application Methods

Thinner quantity (by volume)Airless spray 0–10%Air spray 5–20%Roller or brush 0–15%
Recommended nozzle size0.43~0.64mm2.0~3.0mmNone
Recommended spray pressure15~20MPa0.3~0.6MPaNone
Application suitabilityRecommendedApplicableSuitable for small-area repair

Theoretical Spreading Rate

Dry film thickness (µm)80150200
Wet film thickness (µm)100188250
Theoretical spreading rate (m²/L)9.95.34

Application data (typical dry film thickness 100 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C4h24h4h24h/
15°C3h20h3h24h/
25°C1.5h12h1.5h12h/
40°C1h6h40min8h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair. When applied over other existing coatings, remove chalk, zinc salts, grease and other contaminants by suitable methods. When applied over inorganic zinc silicate primers or metal spray surfaces, use an approved tie coat or transitional coat.

Precautions

1. During application, ensure good ventilation and exhaust, keep away from ignition sources, and wear a mask, gloves and other protective equipment; adequate ventilation shall also be maintained during curing. 2. When mixing, first stir the base thoroughly, then add the curing agent in the specified ratio and mix uniformly; adjust the thinner amount according to application requirements and temperature changes, and mix and induce thoroughly. 3. When applied over inorganic zinc silicate coatings, a tie-coat shall be used for sealing; the product shall be applied only after the tie-coat is hard dry, otherwise the effectiveness of sealing pinholes will be reduced. 4. Excessive thinning will reduce sag resistance and slow curing. 5. Over-thick application will seriously affect drying, curing, overcoating performance and handling time. For better coating performance, when the film thickness exceeds 200 µm, apply in multiple coats to improve film density. Avoid over-thick application in a single pass on edges, corners, welds and similar areas; where these areas have been over-applied, the overcoating interval of subsequent coats shall be extended to allow solvent release, otherwise the coating may crack in service. 6. If the coating chalks after long-term exposure, wash with high-pressure water or abrade the surface before applying the next coat. 7. With roller application, high film thickness and a good continuous film cannot be obtained in a single pass; multiple coats are required. 8. During application and curing, the substrate temperature shall be above 5 °C and at least 3 °C above the dew point, and the relative humidity shall not exceed 85%. Good resistance to liquid media is achieved only after full cure of the film; the degree of cure depends on temperature, humidity and film thickness. At 25 °C and 50% humidity, a 200–300 µm coating requires at least 7–10 days of conditioning before contact with liquid media; as the temperature drops or the film thickness increases, the conditioning time shall be extended. At 10–15 °C, the coating requires at least 21 days of conditioning before service. Do not apply the product below 5 °C. 9. Cutting structures coated with this coating produces fumes; appropriate protection shall be taken. 10. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If work is interrupted for too long, remix a fresh batch of paint before resuming. 11. All equipment shall be cleaned with thinner immediately after use. Periodically flushing spray equipment during the daily work is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, spraying time and interruptions. 12. Remaining paint and empty cans shall be disposed of in accordance with relevant local regulations.

Packaging

24.5 kg per unitBase 21 kgCuring agent 3.5 kg
16 L per unitBase 12.7 LCuring agent 3.3 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery