Zincene Graphene Zinc-rich Primer GrapheneZn HS is a zinc-rich primer. A graphene-reinforced epoxy zinc dust coating used as a high-performance anti-corrosive primer for corrosion protection of facilities and equipment in severe environments such as petrochemical plants, chemical plants, power plants, bridges and offshore structures; complies with the requirements of ISO12944 for zinc dust primers. Parameters on this page: volume solids 66 ± 2%, dry film thickness 60/80/100 µm, theoretical spreading rate 6.6 m²/L.
Parameter source: T&H original technical data sheet (TDS) "Xinxiwang Graphene Zinc-rich Primer GrapheneZn HS"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 66 ± 2% |
|---|---|
| Dry Film Thickness | 60/80/100 µm |
| Theoretical Spreading Rate | 6.6 m2/L |
| VOC | 330g/L |
| Density / Specific Gravity | 2.73kg/L |
| Number of Components | Two-component |
| Flash Point | 25°C |
| Thinner | 0-10% |
| Mixing Ratio | Base : curing agent = 16:1 (by weight), 82:18 (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
A graphene-reinforced epoxy zinc dust coating, used as a high-performance anti-corrosive primer for protection of facilities and equipment in harsh environments such as petrochemical plants, chemical plants, power plants, bridges and offshore structures; complies with the ISO 12944 requirements for zinc dust primers.
| Colour | Zinc grey |
|---|---|
| Gloss | N/A |
| density | 2.73kg/L |
| Volume Solids | 66±2% |
| Volatile Organic Compounds | 330g/L |
| Flash Point | 25°C |
| Mixing ratio | Base : curing agent = 16:1 (by weight), 82:18 (by volume) |
| Typical dry film thickness | 60µm |
|---|---|
| Recommended dry film thickness | 60–100 µm, depending on system requirements |
| Induction time (20 °C) | 10~15min |
| Thinner quantity (by volume) | Airless spray 0–10% | Air spray 10–20% | Roller or brush 0–10% |
| Recommended nozzle size | 0.43~0.64mm | 2.0~3.0mm | None |
| Recommended spray pressure | 15~20MPa | 0.3~0.6MPa | None |
| Application suitability | Recommended | Applicable | Suitable for small-area repair |
*Use a slow thinner in hot weather
| Dry film thickness (µm) | 60 | 80 | 100 |
| Wet film thickness (µm) | 91 | 121 | 152 |
| Theoretical spreading rate (m²/L) | 11 | 8.2 | 6.6 |
| Temperature | Surface Dry | Hard Dry | Pot Life | Recoat interval | |
| Minimum | Maximum* | ||||
| 5°C | 2h | 24h | No data | 24h | / |
| 15°C | 1.5h | 8h | 6h | 12h | / |
| 25°C | 1h | 6h | 4h | 8h | / |
| 40°C | 50min | 4h | 2h | 6h | / |
*The maximum recoat interval depends on the exposure environment and the end use of the coating.
All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair with this primer. If the old film shows chalking or zinc salts, remove the zinc salts and contaminants before applying the intermediate coat or topcoat.
1. Ensure ventilation and exhaust during application; keep away from ignition sources; wear protective equipment such as masks and gloves; maintain adequate ventilation during curing. 2. When mixing paint, stir the base uniformly first, then add the hardener according to the mixing ratio and mix uniformly; adjust thinner consumption according to application requirements and temperature changes; stir thoroughly and allow induction; filtration through a mesh filter is recommended before use; maintain continuous stirring during use. 3. Excessive thinner addition reduces sag resistance; thinner consumption shall not exceed limits in environmental regulations. 4. This product is suitable only for application to blast-cleaned steel surfaces and approved epoxy zinc dust coating and inorganic zinc silicate coating surfaces; it shall not be applied over other types of coatings. Alkyd and alkyd-modified coatings shall not be applied directly over this product's coating. 5. During application and curing, substrate temperature must be above 5°C and at least 3°C above dew point; relative humidity shall not exceed 85%. 6. Cutting structures coated with this paint generates fumes and dust; appropriate protection shall be provided. 7. This product is not suitable for underwater use. 8. Avoid dry spray or excessive film thickness during application. Application of the next coat over a "dry spray" coating may cause pinholes; excessive thickness will extend curing time, handling time and recoating time. Coating thickness must match surface roughness; low film thickness shall not be applied to surfaces with high roughness, and excessive thickness shall be avoided. The paint contains special fillers to improve intercoat adhesion; therefore, the film may appear relatively rough at low thickness, but this does not affect anti-corrosive performance. 9. When work is suspended, do not leave paint in paint lines, spray guns or spraying equipment. Flush all equipment thoroughly with thinner. If the suspension period is too long, it is recommended to mix a new batch of paint for application. 10. All equipment shall be cleaned with thinner immediately after use. Periodic flushing of spraying equipment during daily work is good practice. Cleaning frequency depends on spray volume, temperature, spraying time, including interruption time, among other factors. 11. Residual paint and empty cans shall be disposed of in accordance with relevant local regulations.
| 12.5 L per unit | Base 10.3 L | Curing agent 2.2 L |
| 34 kg per unit | Base 32 kg | Curing agent 2 kg |
*In some special cases, other packaging sizes may be used.
Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.
1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations.
3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.
The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.