← Back to PPG brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

PPG SIGMALINE 403 HS Two-component Low-drag High-solids Polyamine-cured Epoxy Pipe Internal Lining

Quick Specs

PPG SIGMALINE 403 HS Two-component Low-drag High-solids Polyamine-cured Epoxy Pipe Internal Lining is an epoxy coating. Two-component low-drag high-solids polyamine-cured epoxy pipe internal lining. It reduces frictional drag on the internal walls of steel pipelines carrying clean natural gas. Specifications on this page: volume solids 78 ± 2%, DFT 50-100 µm (2.0-4.0 mil) depending on surface preparation, theoretical spreading rate 15.6 m²/L. Comparable products of the same brand and type: AMERCOAT 114 A Epoxy Filler 114 A, AMERCOAT 240 SIGMACOVER 240 High-solids Multi-purpose Epoxy 240, AMERCOAT 370 Rapid-dry Multi-purpose Epoxy Coating 370.

Parameter source: PPG manufacturer's Technical Data Sheet (TDS) "PPG SIGMALINE 403 HS Two-component Low-flow-resistance High-solids Polyamine-cured Epoxy Pipeline Internal Lining"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids78 ± 2%
Dry Film Thickness50–100 µm (2.0–4.0 mil) depending on surface preparation condition
Theoretical Spreading Rate15.6 m²/L
VOCmaximum 165.0 g/kg (EU Directive 2010/…
Density / Specific Gravity1.5 kg/L (12.1 lb/US gal)
Number of ComponentsTwo-component
Thinner0–3%, depending on the required film thickness and application conditions
Recoat IntervalMinimum time: 8 h

Browse Similar Models by CategoryThis model belongs to: Epoxy

IntroductionTwo-component low-flow-resistance high-solids polyamine-cured epoxy internal pipe coating

Key properties

Colour and gloss

Basic data 20 °C (68 °F)

Parameters after mixing

Number of ComponentsTwo-component
Density1.5 kg/L (12.1 lb/US gal).
Volume solids78 ± 2% .
VOC (as supplied)Maximum 165.0 g/kg (EU Directive 2010/75/EC, SED).

Maximum 239.0 g/L (approx. 2.0 lb/gal) (theoretical calculated value).

Recommended dry film thickness50–100 µm (2.0–4.0 mil), depending on surface preparation condition.
Theoretical Spreading Rate15.6 m²/L at 50 µm (626 ft²/US gal at 2.0 mil).
Touch Dry3.5 h
Recoat IntervalMinimum time: 8 h.

Maximum time: 2 months.

Full cure time7 days
Storage shelf lifeBase: at least 12 months; store in a dry and cool environment.

Curing agent: at least 12 months; store in a dry and cool environment.

Notes

Recommended substrate condition and temperature

Substrate condition

Notes

Substrate temperature and application conditions

Instructions for use

Mixing ratio by volume: base : curing agent = 4:1

Application

Induction Time

0 min

Notes

Pot life3 h at 20 °C (68 °F).

Notes

Airless spray (single-feed pump)

Recommended thinner

THINNER 21-06

Thinner quantity0–3%, depending on the required film thickness and application conditions.
Nozzle tip sizeApprox. 0.48–0.64 mm (0.019–0.025 in).
Nozzle pressure16.0–22.0 MPa (approx. 160–220 bar; 2321–3191 psi)
Thinner quantity0 - 3% .

Supplementary parameters

Film thickness and theoretical spreading rate

Dry Film ThicknessTheoretical Spreading Rate
50 µm (2.0 mils)15.6 m²/L (626 ft²/US gal)
75 µm (3.0 mils)10.4 m²/L (417 ft²/US gal)
100 µm (4.0 mils)7.8 m²/L (313 ft²/US gal)

Curing time for a coating at 75 µm (3.0 mils) dry film thickness

Substrate TemperatureTouch dry (surface dry)Hard dryFully cured
5°C (41°F)9 h16 h21 days
10°C (50°F)7 h14 h14 days
20°C (68°F)3.5 h8 h7 days
25°C (77°F)2.5 h6 h6 days
30°C (86°F)2 h5 h5 days

Notes

Pot life (at normal application viscosity)

Mixed paint temperaturePot life
5°C (41°F)6 h
10°C (50°F)4 h
20°C (68°F)3 h
30°C (86°F)2 h
40°C (104°F)1 h

Product certifications

Safety Precautions

Worldwide applicability

Although PPG Protective & Marine Coatings is committed to providing completely consistent products to users worldwide, from time to time it may be necessary to make minor adjustments to specific products to comply with local/national regulations or environmental requirements. In the following cases, use the corresponding alternative version of the product data sheet instead.

Reference information

Quality guarantee

PPG warrants (1) that it has good title to the product, (2) that the product quality conforms to the relevant technical quality specifications in force at the date of manufacture of the product, and (3) that the supplied product is free of lawful claims by third parties for infringement of US patent rights. The above warranties are limited to those given by PPG and other express or implied warranties required by applicable laws and regulations for transactions and commercial practice; any abuse contrary to the stated conditions, and any other warranty for special purposes or uses, are excluded, and PPG shall be free from liability. To claim under this warranty, the buyer must notify PPG in writing within five (5) days of discovering the quality defect, and the date must be within the product's valid storage period or within one (1) year from delivery of the product to the buyer. If the buyer fails to notify PPG of the defect as required above, this will prejudice the buyer's right to obtain compensation under this warranty from PPG!

Limitation of liability

In all cases, PPG shall not be liable for any indirect, special, incidental or consequential loss of any kind arising from or in connection with the use of this product (whether based on negligence, strict liability or tort). The information in this product data sheet is based on laboratory tests we believe to be reliable, and is provided for guidance only. PPG may revise this information at any time as experience accumulates and product development progresses. All recommendations and advice concerning the use of this product, whether in technical documents, in response to an enquiry or otherwise, are given to the best of our knowledge and are believed to be reliable. Our products and related information are provided for industrial users possessing the necessary knowledge and practical skills, and it is the end user's responsibility to determine whether the product is suitable for the specific use. The buyer, having performed such evaluation, proceeds entirely at its own risk. The quality and condition of the substrate on site, and the many other factors affecting product use and application, are beyond PPG's control. Therefore, PPG accepts no liability for any loss, injury or damage arising from the use of the information in this product data sheet (unless otherwise provided in a written agreement). Different application environments, changes to the application process or extrapolation of the reference data may result in failure to achieve the expected coating quality. This product data sheet supersedes all previous versions. The buyer is responsible for confirming that the data sheet in hand is the latest version before using the product. The latest version is published on the official website of PPG Protective & Marine Coatings: www.ppgpmc.com. In case of discrepancy between the Chinese version and the original English version of the product data sheet, the English original shall prevail.

The PPG logo, and all other PPG marks are property of the PPG group of companies. All other third-party marks are property of their respective owners.

FAQ

How many components does PPG SIGMALINE 403 HS have?
PPG SIGMALINE 403 HS is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What dry film thickness is typically applied for PPG SIGMALINE 403 HS?
The typical dry film thickness of PPG SIGMALINE 403 HS is 50–100 µm (2.0–4.0 mil), depending on surface preparation condition; the specific value follows the coating system and design requirements.
What is the theoretical spreading rate of PPG SIGMALINE 403 HS?
The theoretical spreading rate of PPG SIGMALINE 403 HS is 15.6 m²/L; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of PPG SIGMALINE 403 HS?
The volume solids of PPG SIGMALINE 403 HS is 78 ± 2%.
What is the VOC of PPG SIGMALINE 403 HS?
The VOC of PPG SIGMALINE 403 HS is maximum 165.0 g/kg (EU Directive 2010/….
Which thinner is used for PPG SIGMALINE 403 HS?
Recommended thinner for PPG SIGMALINE 403 HS: 0–3%, depending on the required film thickness and application conditions.
Which standards apply to PPG SIGMALINE 403 HS?
As recorded in the technical data on this page: meets the requirements of edition 4 of RP512 of the American Petroleum Institute (API); meets the requirements of the European standard EN10301 for drag-reducing internal coatings for gas transmission; ISO 8501 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can PPG SIGMALINE 403 HS be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings; PPG PPG is one of our regularly stocked brands, with coating selection, system design and quantity calculation support. Address: 10F, Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai, China. Tel: +86 21 5056 8299 (9:00–21:00).

Similar models from the same brand — epoxy coating

View all PPG models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery