China-based coatings exporter — industrial & marine protective coatings from China's production bases

AL054 Alkyd Anti-corrosive Primer

Quick Specs

AL054 Alkyd Anti-corrosive Primer is an alkyd coating used as a primer. Suitable for corrosion protection of steel structures in C2–C4 atmospheric corrosion environments, with convenient application. One-component, with iron red, zinc oxide, phosphate or molybdate added as anti-corrosive pigments, environmentally friendly and free of lead and chromium heavy metals; the film shows strong adhesion to steel substrates and good anti-corrosive performance, with strong intercoat adhesion to nitrocellulose and alkyd topcoats. Parameters on this page: dry film thickness 50 µm equivalent to 86.2 µm wet film, theoretical spreading rate 8.59 m²/kg, number of components one-component.

Parameter source: OSAKA manufacturer's Technical Data Sheet (TDS) "AL054 Alkyd Anti-corrosive Primer"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids58%
Dry Film Thickness50 µm corresponds to 86.2 µm WFT
Theoretical Spreading Rate8.59 m²/kg
VOC361 g/L
Density / Specific GravityApprox. 1.35 kg/L
Number of ComponentsOne-component
Flash Point38°C
ThinnerOUP 100, recommended addition 3%–5%
Mixing RatioSingle pack

Browse Similar Models by CategoryThis model belongs to: Primer, Alkyd

Product Description

One-component, with iron red, zinc oxide, phosphate or molybdate added as anti-corrosive pigments, environmentally friendly and free of lead and chromium heavy metals; the film shows strong adhesion to steel substrates and good anti-corrosive performance, with strong intercoat adhesion to nitrocellulose and alkyd topcoats.

Use

Suitable for corrosion protection of steel structures in C2–C4 atmospheric corrosion environments, easy to apply.

Product Data

Volume Solids58%
Dry Film Thickness50 µm corresponds to 86.2 µm WFT
Theoretical Spreading Rate8.59 m²/kg
Practical Spreading RateAllowing a suitable loss
Volatile organic compound content361 g/L

Application details

Mixing RatioSingle pack
Airless sprayRecommended: nozzle tip size 0.43–0.53 mm; fluid pressure ≥17.6 MPa
Brush or rollerRecommended
Conventional spraySuitable but not recommended.
ThinnerOUP 100, recommended addition 3%–5%.
Paint equipment cleanerOUP 100
Pot lifeUnlimited
Drying Time
Substrate TemperatureTouch dry (h)Hard dry (h)Recoat Interval
MinimumMaximum
5°C23030 hUnlimited
23°C11818 hUnlimited
35°C0.51212 hUnlimited

Storage and packaging

StorageStore in a cool, dry environment
Shelf life1 year
Packaging Specifications20 kg in a 20 L container
Flash Point38°C
densityApprox. 1.35 kg/L

Technical requirements and surface preparation

Steel surfaces: abrasive blast clean to Sa 2.5 (ISO 8501:2007) or clean by hand or power tools to St 3. Keep clean and dry.

Limitation

Shall not be overcoated with epoxy or polyurethane coatings.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

FAQ

How many components does AL054 have?
AL054 is a one-component product; stir thoroughly after opening the can and it is ready for application, with no on-site mixing required.
What is the mixing ratio of AL054?
The mixing ratio of AL054 is single-can.
What dry film thickness is typically applied for AL054?
The typical dry film thickness of AL054 is 50 µm, equivalent to 86.2 µm wet film; the specific value depends on the coating system and design requirements.
What is the theoretical spreading rate of AL054?
The theoretical spreading rate of AL054 is 8.59 m²/kg; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of AL054?
The volume solids of AL054 is 58%.
What is the VOC of AL054?
The VOC of AL054 is 361 g/L.
Which thinner is used for AL054?
Recommended thinner for AL054: OUP 100, at a suggested addition of 3%–5%.
What is the flash point of AL054?
The flash point of AL054 is 38°C; storage, transport and application shall follow the product Safety Data Sheet.
Which standards apply to AL054?
As recorded in the technical data on this page: ISO 8501:2007 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can AL054 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery