China-based coatings exporter — industrial & marine protective coatings from China's production bases

METALCARE AC Abrasion-resistant Epoxy AC

Quick Specs

METALCARE AC Abrasion-Resistant Epoxy AC is an epoxy coating used as a primer. Used on ship bottoms, freeboards, waterlines, decks, cargo holds and other areas; it can be used as a primer in underwater environments. A high build anti-abrasion and anti-corrosive primer. Parameters on this page: volume solids 66 ± 2%, dry film thickness 75-200 µm/coat, theoretical spreading rate 6.6 m²/L. Comparable models from the same brand: EPOMARINE GX epoxy GX, EPOTECT GX anticorrosive primer, AMEINCOAT ZINC PRIMER.

Parameter source: KANSAI original technical data sheet (TDS) for METALCARE AC Abrasion-Resistant Epoxy AC; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids66 ± 2%
Dry Film Thickness75–200 µm per coat
Theoretical Spreading Rate6.6 m²/L per 100 µm
VOC340 g/L, compliant with EU Solvent Emissions Directive 2004/42/EC, subcategory j
Density / Specific Gravity—
Number of ComponentsTwo-component
Flash PointAbove 20 °C
ThinnerEpoxy Thinner #20
Mixing RatioBase/Hardener=7/1(by weight)

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

Metalcare ACAbrasion-Resistant Epoxy AC

PRODUCT DESCRIPTION

A high build anti-abrasion and anti-corrosive primer.

RECOMMENDED USE

For hull bottoms, boottops and topsides decks, cargo holds, etc . As a primer for in-water service.

FEATURES

Super outstanding corrosion resistance

PHYSICAL PROPERTIES

ColorGrey and Oxide Red
ColourGrey and iron red
Volume Solids66±2%
VOC340g/L,accord with EU Dircrtive2004/42/EC,subcategory j
Volatile organic compound content340 g/L, compliant with EU Solvent Emissions Directive 2004/42/EC, subcategory j
Flash PointGreater than 20°C
Flash PointAbove 20 °C
Film thicknessDry 75-200 microns/coat Wet : 113-303microns/coat
Applied film thicknessDry film: 75-200 µm/coat; wet film: 113-303 µm/coat
Theoretical Coverage6.6 m2/Ltr/100 microns
Theoretical spreading rate6.6 m²/L per 100 µm

Practical coverage depending on surface conditions, environment, applications, etc.

APPLICATION

Application Temperature5°C-40°C
MixingCombine Base with Hardener, mix thoroughly with power agitator
MixingMix the base and curing agent and stir thoroughly with a power tool
Mixing RatioBase/Hardener=7/1(by weight)
Mixing ratioBase : curing agent = 7:1 (by mass)
Pot life10°C20°C30°C
Pot life12hrs8hrs6hrs
Application MethodsAirless spray, air spray , brush and roller
Application MethodsAirless spray, air spray, brush and roller
Nozzle tipNozzle size0.43mm-0.53mm
Nozzle pressureOutput pressure≥10Mpa
Thinning ratio0–5% by volume

Brush/Roller; Thinning ratio 5–10% by volume

ThinnerEpomarine Thinner #20
ThinnerEpoxy Thinner #20
Drying time & Overcoating intervalDrying time & Surface dryDrying time & touch dry10°C 3hrs20°C 1hr30°C 30mins
Drying time & recoat intervalTouch drySemi-hard dry24hrs16hrs12hrs
Before floodingDry to immersion7days
Min. intervalMinimum recoat interval24hrs16hrs12hrs
Max. intervalMaximum recoat interval7days
Typical undercoat; suitable undercoatBare steel, SD ZINC 500 etc.
Typical topcoatBare steel, epoxy zinc-rich coating 500, and similar
Suitable for overcoatingRETAN 6000, or according to the coating system of Cosco Kansai.

Polyurethane Topcoat 6000, or refer to the company's coating system

STORAGE

Store in dry, cool condition and away from sources of heat and ignition. Containers must be kept

tightly closed.

Shelf life12 months from date of production (25°C)
Shelf life12 months from date of production (25 °C)

DISCLAIMER

The information given on this sheet is to the best of our knowledge and accurate at the time of

issuing. Since conditions of use are beyond the manufacturer’s control, information contained herein is without warranty, implied or otherwise, and the suitability of the material for the use contemplated is the sole responsibility of the buyer. The information contained on this data sheet is subject to modification at any time due to our policy of modification and product development.Please check this date sheet is current prior to using the product.

The information provided in this data sheet is, to the best of our knowledge, the most complete and accurate information currently available. As the conditions of product use are beyond our control, this information carries no warranty, and we are responsible to the buyer only in the selection of the product. As our products and production processes are continuously developed, the content of this data sheet is subject to change at any time, and all information herein is subject to our confirmation. Confirm that the data sheet in hand is the latest version before using the product.

Issued Date2024/12

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

How many components is METALCARE AC?
METALCARE AC is a two-component product; mix in the ratio given in the Application Data table on this page before use.
What is the mixing ratio of METALCARE AC?
The mixing ratio of METALCARE AC is Base/Hardener = 7/1 (by weight).
What dry film thickness is typically applied for METALCARE AC?
The typical dry film thickness of METALCARE AC is 75-200 µm/coat; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of METALCARE AC?
The theoretical spreading rate of METALCARE AC is 6.6 m²/L / 100 µm; the practical quantity is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of METALCARE AC?
The volume solids of METALCARE AC is 66 ± 2%.
What is the VOC of METALCARE AC?
The VOC of METALCARE AC is 340 g/L, compliant with EU Solvent Emissions Directive 2004/42/EC, subcategory j.
What thinner is used for METALCARE AC?
Recommended thinner for METALCARE AC: Epoxy Thinner #20.
What is the flash point of METALCARE AC?
The flash point of METALCARE AC is above 20 °C. Storage, transport and application are subject to the product safety data sheet.
How is METALCARE AC applied?
Application method for METALCARE AC: airless spray, air spray, brush and roller; surface preparation and the coating system are as described on this page.
Where can METALCARE AC be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings; KANSAI KANSAI is one of our regularly stocked brands, with coating selection, system design and quantity calculation support. Address: 10F, Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai, China. Tel: +86 21 5056 8299 (9:00–21:00).