China-based coatings exporter — industrial & marine protective coatings from China's production bases

Iron Oxide Epoxy Anti-corrosive H53-31

Quick Specs

Iron oxide epoxy anti-corrosive paint H53-31 belongs to epoxy paints and is used as a primer. Suitable for use as an anti-corrosive primer on wharf steel structures, shipbuilding, heavy machinery, power machinery, chemical enterprises, mining machinery, hydraulic steel structures and other applications. A two-component epoxy anti-corrosive paint composed of epoxy resin, polyamide curing agent, iron oxide red, zinc yellow, additives, solvents and other components. Has good compatibility with epoxy and polyurethane topcoats and good intercoat adhesion. Parameters on this page: volume solids 51 ± 3% (after mixing), dry film thickness 50 µm, theoretical spreading rate 133 g/m².

Parameter source: KAILIN original technical data sheet (TDS) \"Iron Oxide Red Epoxy Anti-Corrosive Paint H53-31\"; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids51 ± 3% (after mixing)
Dry Film Thickness50µm
Theoretical Spreading Rate133 g/m²
VOC—
Density / Specific Gravity—
Number of ComponentsTwo-component
Flash Point27°C
ThinnerThinner 103
Mixing RatioComponent A : Component B = 26:3 (by weight)

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

FAQ

What is the mixing ratio of Iron Oxide Red Epoxy Anti-Corrosive Paint?
The mixing ratio of Iron Oxide Red Epoxy Anti-Corrosive Paint is Component A:Component B = 26:3 (by weight).
What dry film thickness is typically applied for Iron Oxide Red Epoxy Anti-Corrosive Paint?
The conventional dry film thickness of Iron Oxide Red Epoxy Anti-Corrosive Paint is 50 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Iron Oxide Red Epoxy Anti-Corrosive Paint?
The theoretical spreading rate of Iron Oxide Red Epoxy Anti-Corrosive Paint is 133 g/m²; actual consumption is adjusted for substrate roughness, application loss and colour opacity.
What is the volume solids of Iron Oxide Red Epoxy Anti-Corrosive Paint?
The volume solids of Iron Oxide Red Epoxy Anti-Corrosive Paint is 51 ± 3% (after mixing).
What thinner is used for Iron Oxide Red Epoxy Anti-Corrosive Paint?
Thinner for Iron Oxide Red Epoxy Anti-Corrosive Paint: 103 Thinner.
What is the flash point of Iron Oxide Red Epoxy Anti-Corrosive Paint?
The flash point of Iron Oxide Red Epoxy Anti-Corrosive Paint is 27 °C. Storage, transport and application shall follow the product safety data sheet.
Which standards apply to Iron Oxide Red Epoxy Anti-Corrosive Paint?
The technical data on this page states: GB/T9272 (see application instructions on this page); ISO3233:1998 (see application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the recommended coating system.
Where can Iron Oxide Red Epoxy Anti-Corrosive Paint be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Composition

Two-component epoxy resin, polyamide curing agent, iron oxide red, zinc yellow, additives, solvents and other components

component epoxy anti-corrosive paint.

Key characteristics

Good compatibility with epoxy and polyurethane topcoats and good intercoat adhesion

Use

Suitable for use as an anti-corrosive primer on dock steel structures, shipbuilding, heavy machinery, power machinery, chemical enterprises, mining machinery,

Used as an anti-corrosive primer for hydraulic steel structures and other applications.

AppearanceIron red, matt

Application parameters

Volume Solids51 ± 3% (determined in accordance with GB/T9272 eqv ISO3233:1998) (after mixing)
Mixing ratioComponent A : Component B = 26:3 (by weight)
Dry Film Thickness50µm
Wet Film Thickness98µm
Theoretical quantity133g/m²
Flash PointComponent A27°C
Component B27°C
Drying time (25 °C)Touch dry ≤ 2 h, hard dry ≤ 24 h, fully cured 7 days
Induction time (after mixing) (20 °C)30min
Pot life (after mixing)
Temperature5°C20°C30°C40°C
Pot life12h8h6h4h
Recoat interval
Temperature5°C20°C30°C40°C
Minimum48h24h16h8h
Maximum14d7d5d
Recommended number of coatsAirless spray 1–2 coats, or brush/roller 2–3 coats, at a dry film thickness above 100 µm.
Subsequent coat842 Epoxy Micaceous Iron Oxide Anticorrosive Paint, or epoxy topcoat, polyurethane topcoat and other finishes.

Surface Preparation

Mill-scale-free steel: abrasive blast clean to Sa 2.5 or grind with abrasive discs to St 3

Shop-primed steel: sweep-blast, or abrade with a flexible disc to St3

Welded, flame-cut or heat-straightened areas: remove weld slag and spatter, grind flat, then grind to St3 with a flexible grinding disc

Application conditions

Below 5 °C, the curing reaction between epoxy and curing agent stops; outdoor application is not advisable

Application method

Airless Spray
ThinnerThinner 103
Thinning quantity0–5% (by paint weight)
Nozzle tip size0.4-0.5mm
Spray output pressure20–25 MPa (approx. 200–250 kg/cm²)
Air Spray
Not recommended for large areas; suitable only for small-area touch-up or small workpieces
ThinnerThinner 103
Thinning quantity0–10% (by paint weight)
Nozzle tip size2.0-3.0mm
Air pressure0.3–0.4 MPa (approx. 3–4 kg/cm²)
Roller/brushThinner 103, thinning 0–3% (by weight of paint)
Cleaning solventThinner 103
Safety measuresSee the Safety Data Sheet (MSDS) of Shanghai Kailin Paint Factory.
PackagingComponent A: 26 kg in a 20 L drum; Component B: 3 kg in a 4 L drum
Shelf Life12 months
NotesTo use this product correctly, read the Application Guide in this data sheet carefully.

Disclaimer

The above information and data for this product are accumulated from our tests and practical experience

accumulated, and may serve as an application guide. For application carried out under conditions unknown to us, we

We guarantee only the quality of the paint itself and accept no responsibility for other matters. We

and reserve the right to make modifications as the product is improved.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery