Inorganic zinc silicate anti-corrosive paint E06-1 is an inorganic zinc silicate paint used as a primer. Suitable for offshore platforms, dock steel piles, mine steel supports, bridges and large steel structures as a high-performance anti-corrosive paint. Two-component inorganic zinc silicate anti-corrosive paint composed of alkyl silicate polymer, zinc dust, pigments, additives and alcohol solvents. High heat resistance; the film withstands temperatures up to 400°C. High impact resistance, good abrasion resistance and moderate flexibility. Parameters on this page: volume solids 44 ± 3% (after mixing), dry film thickness 70 µm, theoretical spreading rate 312 g/m².
Parameter source: KAILIN manufacturer's Technical Data Sheet (TDS) "Inorganic Zinc Silicate Anti-corrosive Paint E06-1"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 44 ± 3% (after mixing) |
|---|---|
| Dry Film Thickness | 70µm |
| Theoretical Spreading Rate | 312 g/m² |
| VOC | — |
| Density / Specific Gravity | — |
| Number of Components | Two-component |
| Flash Point | 13°C |
| Thinner | Thinner 107 |
| Mixing Ratio | Component A : Component B = 3:1 (by weight) |
Two-component, composed of alkyl silicate polymer, zinc dust, pigments, additives and alcohol solvents
Inorganic zinc silicate anti-corrosive paint.
High heat resistance; the film withstands temperatures up to 400°C.
High impact resistance, good abrasion resistance and moderate flexibility.
| Use | Suitable for offshore platforms, dock steel piles, mine steel supports, bridges and large steel structures as a high-performance anti-corrosive paint. |
|---|---|
| Appearance | Grey matt |
| Volume Solids | 44 ± 3% (determined according to GB/T9272 eqv ISO3233:1998) (after mixing) |
|---|---|
| Mixing ratio | Component A : Component B = 3:1 (by weight) |
| Dry Film Thickness | 70µm |
| Wet Film Thickness | 159µm |
| Theoretical quantity | 312g/m² |
| Flash Point | Component A | 13°C |
| Component B | 13°C |
| Drying time (25 °C) | Touch dry ≤1 h; hard dry ≤24 h; recoating interval |
|---|
Minimum recoating interval: more than 24 h; before painting, wipe the surface of the E06-1 film with a cloth dipped in Thinner 107,
to determine whether the film is fully cured. If zinc dust dissolves on the cloth, the film is not fully cured,
and it must continue drying; when relative humidity is below 70%, water may be sprinkled on the film to promote film
curing; dry until the cloth is colourless (no dissolution), indicating that the film is fully cured, before proceeding
to apply the next coat. The maximum recoating interval is unlimited, but zinc salts must be removed before recoating.
| Pot life (after mixing components A and B) | |||
| Temperature | 5°C | 20°C | 30°C |
| Pot life | 24h | 12h | 6h |
| Recommended number of coats | Spray one coat; a dry film thickness within 70 µm is recommended. |
|---|
Can be used in combination with chlorinated rubber, epoxy, epoxy bitumen, bituminous, polyurethane, vinyl and other coatings
but cannot be used in combination with oil-based, alkyd or polyester paints.
| Surface Preparation | Steel abrasive blast cleaning to Sa2.5; surface roughness 35–75 µm |
|---|
When the substrate temperature is too high (≥ 40 °C), spray application is required, but the substrate temperature shall not
exceed 60 °C. To avoid dry spray, add Thinner 107 until dry spray is eliminated
| Airless Spray | |
| Thinner | Thinner 107 |
| Thinning quantity | 0–10% (by paint weight) * guard against dry spray |
| Nozzle tip size | 0.4-0.5mm |
| Spray output pressure | 15 MPa (approx. 150 kg/cm²) |
| Air Spray | |
| Thinner | Thinner 107 |
| Thinning quantity | 0–10% (by paint weight) * guard against dry spray |
| Nozzle tip size | 2.0-2.5mm |
| Air pressure | 0.3–0.6 MPa (approx. 3–6 kg) |
| Roller/brush | |
| Not suitable for large-area application; limited to small-area repair coating. | |
| Thinner | Thinner 107 |
| Thinning quantity | 0–5% (by paint weight) |
| Cleaning solvent | Thinner 107 |
|---|---|
| Safety measures | See the Safety Data Sheet (MSDS) of Shanghai Kailin Paint Factory. |
| Packaging | Component A (zinc dust slurry): 20 L drum, 22.5 kg; Component B (base): 10 L drum, 7.5 kg |
| Shelf Life | 6 months |
Stir continuously with a mixer during application to prevent zinc dust from settling.
During application at temperatures above 30°C, to prevent dry spray, Thinner 107 may be added
until dry spray no longer occurs; the amount of Thinner 107 added is 0–10% of the paint weight.
When the dry film thickness is below the requirement and one additional coat of E06-1 inorganic zinc silicate anti-corrosive paint is required,
E06-1 inorganic zinc silicate anti-corrosive paint should be diluted with 50% Thinner 107 before recoating to improve intercoat adhesion between films.
The film thickness of E06-1 inorganic zinc silicate anti-corrosive paint must not exceed 120 µm; if the dry film thickness is greater
than 120 µm, mud cracking and failure will occur due to internal stress in the film.
To seal the pores on the surface of the inorganic zinc silicate anti-corrosive paint film and prevent pinhole corrosion, use
H53-42 epoxy sealer or other sealer to seal E06-1 inorganic zinc silicate anti-corrosive paint.
Before applying the next coat of paint, the film of E06-1 inorganic zinc silicate anti-corrosive paint must be fully cured,
otherwise intercoat adhesion and anti-corrosion performance will be affected. Before painting, use a cloth dipped in Thinner 107
to wipe the film; if no colour appears on the cloth (that is, no dissolution), the film is fully cured, and the subsequent coat may then be applied.
Relative humidity below 70% is unfavourable to the hydrolytic curing reaction of inorganic zinc silicate anti-corrosive paint; to promote
film curing, sprinkle water appropriately on the film every 2 h starting 3 h after application.
The maximum recoating interval for E06-1 inorganic zinc silicate anti-corrosive paint is unlimited, but before applying the next
coat of paint, zinc salts formed on the film surface must be thoroughly removed; otherwise the intercoat adhesion and protective effect of the film will be affected.
| Notes | To use this product correctly, read the Application Guide in this data sheet carefully. |
|---|
The above information and data for this product are accumulated from our tests and practical experience
accumulated, and may serve as an application guide. For application carried out under conditions unknown to us, we
We guarantee only the quality of the paint itself and accept no responsibility for other matters. We
and reserve the right to make modifications as the product is improved.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.