Tankguard Type II Solvent-free Phenolic Epoxy Coating Type II belongs to epoxy coatings. Industrial protective coatings segment: specifically designed to meet the critical requirements of the oil industry and others. This is a ceramic filler-reinforced two-component solvent-free amine-cured phenolic epoxy coating. Parameters on this page: volume solids 100%, dry film thickness 150–500 µm, theoretical spreading rate 6.7–2 m²/L. Comparable products of the same brand and type: Jotapipe IL 425 Phenolic Epoxy 425 for aviation fuel pipelines, Jotapipe IL 426 Phenolic Epoxy 426 for sour crude oil pipelines, Tankguard NCV N Phenolic Epoxy Static Conductive Coating.
Parameter source: JOTUN original Technical Data Sheet (TDS) 'Tankguard Type II Solvent-free Phenolic Epoxy Coating Type II'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 100% |
|---|---|
| Dry Film Thickness | 150–500 µm |
| Theoretical Spreading Rate | 6.7–2 m²/L |
| VOC | 48 g/L (US) |
| Density / Specific Gravity | 1.4 kg/L |
| Number of Components | Two-component |
| Flash Point | 100 °C |
| Mixing Ratio | 3 parts : 1 part (by volume) |
| Gloss | Gloss (70–85) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Tankguard Type II
This is a two-component, solvent-free, amine-cured phenolic epoxy coating reinforced with ceramic fillers. It is highly resistant to most sour crude oils, many chemicals and solvents. It can be used as a primer, intermediate coat or topcoat in atmospheric and immersion environments. Suitable for properly prepared carbon steel substrates.
Industrial protective coatings:
Designed to meet the critical requirements of the oil industry. Other
Petrobras N-2912 specification for Type II phenolic epoxy coatings. Other certificates and approvals are available upon request.
Munsell 5G8/4, Munsell N6.5, Munsell N9.5
| Property | Test / Standard | Description |
| Volume Solids | ISO 3233 | 100% |
| Gloss (GU 60°) | ISO 2813 | Gloss (70–85) |
| Flash Point | ISO 3679 Method 1 | 100 °C |
| Density | Theoretical Value | 1.4 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 48 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
Typical recommended specification range
| Dry Film Thickness | 150–500 µm |
| Wet Film Thickness | |
| Theoretical Spreading Rate | 6.7–2 m²/L |
| Note | Water jetting is for maintenance only. For new construction, water jetting is permitted only in combination with abrasive blasting. |
|---|
Surface Preparation
| Substrate | Minimum | Recommended |
| Carbon Steel | Sa 2½ (ISO 8501-1) | |
| Coated surface | A clean, dry and sound compatible primer. | |
The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.
This product may be applied by the following methods
| Spray: | Apply by airless spray. |
| Brush: | Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. |
The temperature of both components is recommended to be between 23–28 °C before commencing application.
| Solvent-Free Phenolic Epoxy Coating Type II, Component A | 3 parts |
| Solvent-Free Phenolic Epoxy Coating Type II, Component B | 1 part |
| Cleaner | JOTUN Thinner No. 17 |
|---|
When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements
In China, the cleaning solvent must comply with GB 38508-2020
| Nozzle tip size (inch/1000): | 19-25 |
| Nozzle pressure (minimum): | 175 bar/2500 psi |
Due to the short pot life after mixing, it is particularly important to thoroughly clean the nozzle and other parts of the spray equipment promptly after completion.
| Substrate Temperature | 10 °C | 23 °C | 40 °C |
| Touch Dry | 15 h | 6 h | 1.5 h |
| Walk-on Dry | 30 h | 12 h | 4 h |
| Minimum recoat interval | 30 h | 12 h | 4 h |
| Dry/cured to service | 15 days | 7 days | 4 days |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 23 °C |
| Induction Time | 10 min |
| Pot Life | 45 min |
| Induction time and pot life are reduced at higher temperatures |
Temperature
| Drying, atmospheric | Continuous 140 °C | Peak - |
| Immersed, sea water | 70 °C | - |
| Immersed, crude oil | 80 °C | 90 °C |
Withstands peak temperatures for a maximum of one hour.
At the above temperatures, protective performance is unaffected, but appearance may be affected.
Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | itself |
| Subsequent coat: | itself |
| Volume | Container Size | |
| (L) | ||
| Solvent-Free Phenolic Epoxy Coating Type II, Component A | 15 | 20 |
| Solvent-Free Phenolic Epoxy Coating Type II, Component B | 5 | |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Solvent-Free Phenolic Epoxy Coating Type II, Component A | 12 months |
| Solvent-Free Phenolic Epoxy Coating Type II, Component B | 12 months |
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.