Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating is an epoxy coating. Industrial protective coatings segment: dedicated as a lining coating for offshore, onshore and underground tanks and pipelines, such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water lines and drilling mud tanks. Can be used as primer, intermediate coat or topcoat in atmospheric and immersion environments. Parameters on this page: volume solids 72 ± 2%, dry film thickness 100–200 µm, theoretical spreading rate 7.2–3.6 m²/L.
Parameter source: JOTUN manufacturer's Technical Data Sheet (TDS) "Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 72 ± 2% |
|---|---|
| Dry Film Thickness | 100–200 µm |
| Theoretical Spreading Rate | 7.2–3.6 m²/L |
| VOC | 243 g/L (China) |
| Density / Specific Gravity | 1.5 kg/L |
| Number of Components | Two-component |
| Flash Point | 34 °C |
| Thinner | Jotun Thinner No. 17 / JOTUN Thinner No. 23 |
| Mixing Ratio | 3 parts : 1 part (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Tankguard Storage HS
This is a two-component amine-cured phenolic epoxy coating. Specially designed cargo tank/storage tank lining coating with excellent chemical resistance. Can be used as primer, intermediate coat or topcoat in atmospheric and immersion environments. Suitable for properly prepared carbon steel, galvanized steel, stainless steel and concrete substrates.
Industrial protective coatings:
Designed as a lining for offshore, onshore and underground tanks and pipelines, such as chemical storage, waste water, grey water, industrial water pipelines, concrete bunds, fire-fighting water lines and drilling mud tanks. May be used for pressure vessels. The coating has good resistance to high-temperature products. Refer to the industrial protective coatings corrosion resistance table.
Others
Certified according to IMO Res.288(87) and suitable for the PSPC standard for crude oil tanks. Other certificates and approvals are available on request.
Light grey, light red, red
| Property | Test / Standard | Description |
| Volume Solids | ISO 3233 | 72± 2 % |
| Gloss (GU 60°) | ISO 2813 | Semi-gloss (35–70) |
| Flash Point | ISO 3679 Method 1 | 34 °C |
| Density | Theoretical Value | 1.5 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| China | Mandatory national standard of China | GB 30981.2-2025 | 243 g/L |
| Coating hazards GB | 30981.2-S-Pb≤1000-NC |
Contains reactive thinner
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
Typical recommended specification range
| Dry Film Thickness | 100–200 µm |
| Wet Film Thickness | 140–280 µm |
| Theoretical Spreading Rate | 7.2–3.6 m²/L |
Surface Preparation
| Substrate | Minimum | Recommended |
| Carbon Steel | Sa 2½ (ISO 8501-1) | |
| Coated surface | A clean, dry and sound compatible primer. | |
| Stainless steel | The surface should be blasted with a non-metallic abrasive, | “Blast clean using an approved non-metallic abrasive |
| hand- or machine-sanded using abrasive paper or fibre discs, | to produce a sharp angular surface profile.” | |
to produce scratch marks on the surface.
| Galvanised steel | The surface should be clean, dry and have a suitable profile | Sweep blast with a non-metallic abrasive to produce a clean, |
| ° | a rough and uniform surface. | |
| Concrete | Dry abrasive blast clean to SSPC-SP 13 / NACE No. 6. | |
The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.
This product may be applied by the following methods
| Spray: | Apply by airless spray. |
| Brush: | Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness. |
| Roller: | Roller application may be used only in areas such as drain holes, rat holes and small pipes. |
| Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A | 3 parts |
| Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B | 1 part |
| Thinner | Jotun Thinner No. 17 / JOTUN Thinner No. 23 |
|---|
| Nozzle tip size (inch/1000): | 17-21 |
| Nozzle pressure (minimum): | 150 bar/2100 psi |
| Substrate Temperature | -5 °C | 0 °C | 5 °C | 10 °C | 15 °C | 23 °C | 40 °C |
| Touch Dry | 12 h | 10 h | 5 h | 4 h | 3 h | 2 h | 1 h |
| Walk-on Dry | 48 h | 30 h | 16 h | 12 h | 10 h | 8 h | 4 h |
| Minimum recoat interval | 24 h | 20 h | 10 h | 8 h | 6 h | 4 h | 2 h |
| Dry/cured to service | 30 days | 21 days | 14 days | 10 days | 8 days | 6 days | 3 days |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.
At application temperatures of 23 °C and above, tanks for crude oil and clean petroleum products may be returned to service 48 hours after application of the final coat.
For the resistance list including clean petroleum products, refer to the JOTUN product resistance guide.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 10 °C | 23 °C |
| Induction Time | 5 min | |
| Pot Life | 2 h | 1.5 h |
Temperature
| Drying, atmospheric | Continuous 200 °C | Peak - |
| Immersed, sea water | 70 °C | - |
| Immersed, crude oil | 120 °C | - |
For more detailed resistance information, see the Industrial Protective Products Resistance List on the JOTUN website, or contact your local JOTUN office.
Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Phenolic epoxy |
| Subsequent coat: | Phenolic epoxy |
Tankguard Holding Primer can be used for short-term protection and is fully compatible with the tank coating system.
| Volume | Container Size | |
| (L) | ||
| Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A | 15 | 20 |
| Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B | 5 | |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A | 24 months |
| Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B | 24 months |
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.