← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard SF Solvent-free Phenolic Epoxy Tank Coating

Quick Specs

Tankguard SF Solvent-free Phenolic Epoxy Tank Coating is an epoxy coating. In the industrial protective coatings sector: dedicated as a lining coating for offshore, onshore and underground tanks and pipelines, such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water lines and drilling mud tanks. Can be used as a primer, intermediate coat or topcoat in atmospheric and immersed environments. Parameters on this page: volume solids 100%; dry film thickness 150–500 µm; theoretical spreading rate 6.7–2 m²/L.

Source: JOTUN original technical data sheet (TDS) 'Tankguard SF Solvent-free Phenolic Epoxy Tank Coating'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100%
Dry Film Thickness150–500 µm
Theoretical Spreading Rate6.7–2 m²/L
VOCGB/T 34682-2017 8.3: 23 g/L (China)
Density / Specific Gravity1.5 kg/L
Number of ComponentsTwo-component
Flash Point100 °C
Mixing Ratio2 parts : 1 part (by volume)
GlossGloss (70–85)

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does Tankguard SF contain?
Tankguard SF is a two-component product. Mix to the ratio shown in the Application Data table on this page before use.
What is the mixing ratio of Tankguard SF?
Mixing ratio of Tankguard SF: 2 parts : 1 part (by volume).
What is the typical dry film thickness of Tankguard SF?
Typical dry film thickness of Tankguard SF: 150–500 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of Tankguard SF?
Theoretical spreading rate of Tankguard SF: 6.7–2 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Tankguard SF?
Volume solids of Tankguard SF: 100%.
What is the VOC of Tankguard SF?
VOC of Tankguard SF: GB/T 34682-2017 8.3: 23 g/L (China).
What is the gloss of Tankguard SF?
Gloss of Tankguard SF: glossy (70–85).
What is the flash point of Tankguard SF?
Flash point of Tankguard SF: 100 °C. Storage, transport and application per the product safety data sheet.
How long does Tankguard SF take to dry?
Drying time of Tankguard SF under standard conditions: touch dry 15 h; actual values depend on temperature, film thickness and ventilation.
Which standards apply to Tankguard SF?
As recorded in the technical data on this page: GB/T 34682-2017 (see the application instructions on this page); ISO 3233 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard SF be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard SF

Product description

A two-component, solvent-free, amine-cured phenolic epoxy coating. Specially designed as a cargo hold/tank lining coating with good chemical resistance. Can be used as a primer, intermediate coat or topcoat in atmospheric and immersed environments. Suitable for suitably prepared carbon steel, galvanized steel, stainless steel and concrete substrates.

Typical Use

Industrial protective coatings:

Dedicated as a lining coating for offshore, onshore and underground tanks and pipelines, such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water lines and drilling mud tanks. Meets the API 652 guidance for thick-film reinforced linings. Refer to the Industrial Protective Coatings corrosion resistance table.

Others

Colour

Light yellow, light grey, light red, white

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 3233100%
Gloss (GU 60°)ISO 2813Gloss (70–85)
Flash PointISO 3679 Method 1100 °C
DensityTheoretical Value1.5 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation71 g/L
Hong KongAir Pollution Control (VOC) RegulationCalculation71 g/L
EUEuropean Paint Directive 2004/42/CECalculation71 g/L
ChinaGB 30981-2020 Limit of harmful substances of industrial protective coatingsGB/T 34682-2017 8.3: 23 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness150–500 µm
Wet Film Thickness
Theoretical Spreading Rate6.7–2 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.
ConcreteDry abrasive blast clean to SSPC-SP 13 / NACE No. 6.
Coated surfaceA clean, dry and sound compatible primer.

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.

Mixing Ratio (by Volume)

Tankguard SF Comp A — Solvent-Free Phenolic Epoxy Tank Lining, Component A2 parts
Tankguard SF Comp B — Solvent-Free Phenolic Epoxy Tank Lining, Component B1 part

Thinner / Cleaning Solvent

Do not add thinner.

CleanerJotun Thinner No. 17

When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements

Airless Spray Guidance

Nozzle tip size (inch/1000):19-25
Nozzle pressure (minimum):175 bar/2500 psi

Drying and Curing Time

Substrate Temperature10 °C15 °C23 °C30 °C40 °C
Touch Dry15 h12 h6 h5 h1.5 h
Walk-on Dry30 h24 h12 h9 h4 h
Minimum recoat interval30 h24 h12 h7 h4 h
Dry/cured to service15 days10 days3 days2 days1 day

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 60%, with dry film thickness within the average range.

The maximum acceptable relative humidity at all temperatures is 60%.

For wet-on-wet application, a 2 x 200 µm system is recommended. The recommended interval before the next coat is 20 minutes to 4 hours. With wet-on-wet application, relative humidity above 60% (up to 85%) is allowable, but it will affect the appearance of the final coat (some areas whitening or darkening).

At application temperatures of 23 °C and above, tanks for crude oil and clean petroleum products may be returned to service 48 hours after application of the final coat.

For the resistance list including clean petroleum products, refer to the JOTUN product resistance guide.

For other less aggressive chemicals, early immersion is possible. For details, consult the local Jotun company.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Induction Time10 min
Pot Life1 h

Heat Resistance

Temperature

Drying, atmosphericContinuous 120 °CPeak 140 °C
Immersed, sea water80 °C90 °C
Immersed, crude oil140 °C150 °C

For more detailed resistance information, see the Industrial Protective Products Resistance List on the JOTUN website, or contact your local JOTUN office.

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Phenolic epoxy
Subsequent coat:Phenolic epoxy

Tankguard Holding Primer can be used for short-term protection and is fully compatible with the tank coating system.

Typical Packaging Sizes

VolumeContainer Size
(L)
Tankguard SF Comp A — Solvent-Free Phenolic Epoxy Tank Lining, Component A1020
Tankguard SF Comp B — Solvent-Free Phenolic Epoxy Tank Lining, Component B5

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Tankguard SF Comp A — Solvent-Free Phenolic Epoxy Tank Lining, Component A12 months
Tankguard SF Comp B — Solvent-Free Phenolic Epoxy Tank Lining, Component B12 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Environmental documentation

This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.

EPDs are available at www.epd-norge.no

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery